Maintenance 

 

 

Do not open the device. It uses delicate electrical components and an 
intricate air unit that could be damaged. If you cannot fix the problem 
using the troubleshooting instructions, request service from your dealer 
or from the A&D service group. The A&D service group will provide 
technical information, spare parts and units to authorized dealers. 

 

 

The device was designed and manufactured for a long service life. 
However it is generally recommended to have the monitor inspected 
every 2 years, to ensure proper functioning and accuracy. Please contact 
either your authorized dealer or A&D for maintenance. 

 
 
 

Technical Data 

 

Type UA-787

 

Measurement method 

Oscillometric measurement 

Measurement range 

Pressure:   20 - 280 mmHg 

 

Pulse:   

40 - 200 beats / minute 

Measurement accuracy 

Pressure:   ±3 mmHg or 2%, whichever is greater 

 Pulse: 

 

±5% 

Power supply 

4 x 1.5V batteries (R6P, LR6 or AA) or 

 

AC adapter (TB-182) 

Classification Type 

BF 

      

Clinical test 

According to ANSI / AAMI SP-10 1987 

EMC 

IEC 60601-1-2: 2001 

Memory Last 

60 

measurements 

Operating condition 

+10°C to +40°C / 30%RH to 85 %RH 

Storage condition 

-10°C to +60°C / 30%RH to 85 %RH 

Dimensions 

Approx. 163 [W] x 62 [H] x 112 [D] mm 

Weight 

Approx. 350 g, excluding the batteries 

 

 

 

Accessory AC adapter 

The adapter is to connect the blood pressure 
monitor to a power source at home. 

TB-182 

Please contact your local A&D dealer for 
purchasing. 

 

Note: Specifications 

are 

subject to change without prior notice. 

 
 
 

Содержание UA-787 Plus

Страница 1: ...Digital Blood Pressure Monitor Model UA 787 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Bedienungsanleitung WM PD4001187C...

Страница 2: ...ark On The Display 8 Attaching The Arm Cuff 8 How To Take Proper Measurements 8 Measurement 8 After Measurement 8 Measurements 9 Normal Measurement 9 Measurement With The Desired Systolic Pressure 10...

Страница 3: ...r use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean...

Страница 4: ...tton Air Hose Arm Cuff DC Jack START Button Orange illumination Air Connector Plug Air Socket MEMORY Button Part of Display Pressure Bar Indicator and WHO Classification Indicator MEMORY Systolic Pres...

Страница 5: ...ery The battery power indicator during measurement LowBattery The battery is low when it blinks Replace all batteries with new ones when the indicator blinks Unstable blood pressure due to movement du...

Страница 6: ...o page 11 Press the MEMORY button to recall the data The date and the most recent data are displayed The device can store the last sixty sets of data in memory automatically 3 Clearing Data Refer to p...

Страница 7: ...s Do not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained Battery life varies with the ambie...

Страница 8: ...e current day and move to hour minute selection 5 Select the hour using the START button Press the CLOCK button to set the current hour and move to minute selection 6 Select the minute using the START...

Страница 9: ...ure measurement Sit comfortably at a table Rest your arm on the table Relax for about five to ten minutes before measurement Place the center of the cuff at the same height as your heart Remain still...

Страница 10: ...n Note If you wish to stop inflation at any time press the START button again 3 When inflation is complete deflation starts automatically and heart mark blinks indicating that the measurement is in pr...

Страница 11: ...ited or depressed by emotional stress the measurement will reflect this stress as a higher or lower than normal blood pressure reading and the pulse reading will usually be faster than normal An indiv...

Страница 12: ...ess the MEMORY button 2 The date and the most recent data are displayed 3 When the MEMORY button is pressed while data is displayed the previous data is displayed 4 After the last data is displayed th...

Страница 13: ...ring measurements Note We recommend contacting your physician if you see this indicator frequently Pressure Bar Indicator The indicator monitors the progress of pressure during measurement WHO Classif...

Страница 14: ...regular physical checkups Maintain proper weight Why Measure Blood Pressure At Home Blood pressure measured at a clinic or doctor s office may cause apprehension and can produce an elevated reading 2...

Страница 15: ...etely the mark does not appear Replace all batteries with new ones The cuff is not fastened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain ve...

Страница 16: ...aintenance Technical Data Type UA 787 Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 200 beats minute Measurement accuracy Pressure 3 mmHg or 2 whichever...

Страница 17: ......

Отзывы: