Symbols 

Symbols 

Function / Meaning 

Treatment 

 

Turns on or off the device 

 

 

Sets the clock / Does not store the 
current data 

 

  Direction guide to install battery 

 

 

Direct current 

 

SN Serial 

number 

 

 

Date of manufacture 

 

 

Type BF: Device, cuff and tubing are 
designed to provide special protection 
against electric shocks. 

 

 

Appears when measurement is in 
progress and flashes when the pulse 
is detected. 

Measurement is in progress -- 
remain as still as possible. 

 

Previous measurement stored in 
MEMORY 

 

 

Appears when the battery voltage is 
too low for the device to work properly.

Replace all batteries with new 
ones. 

 

Appears if the systolic and diastolic 
measurements are within 10 mmHg of 
each other. 

Verify that the air hose is 
properly connected and that the 
exhaust rate is between 2 and 5 
mmHg. Check for air leakage. 

 

Appears if the pressure value is 
unstable due to movement during the 
measurement. 

Try the measurement again. 
Remain very still during the 
measurement. 

 

Appears if the pressure value did not 
increase during pump up. 

Verify that the air hose is 
properly connected and that the 
exhaust rate is between 2 and 5 
mmHg. Check for air leakage. 

 

System error 

Reload batteries. 

 

Appears if pulses are not detected 
correctly. 

Attach the cuff properly and try 
the measurement again. 

 

Attention symbol 

See instruction for use 

  EC directive medical device label 

 

 

WEEE label 

 

Содержание UA-767PC

Страница 1: ...Digital Blood Pressure Monitor UA 767PC Instruction Manual 1WMPD4000034E...

Страница 2: ...Measurement 7 6 After the Measurement 7 Measurements 8 Notes for Proper Measurements 10 Data in Memory 11 Storing Data in Memory 11 Recalling Memory Data 11 Erasing Data in Memory 11 Transmitting Rea...

Страница 3: ...The above is evidenced by the mark of conformity 0366 The reference number to the involved notified body The device is designed for use on adults only not newborns or infants Environment for use The...

Страница 4: ...ressure Switch Diastolic Display Start Button Pulse Display Clock Display Data Port Air Socket Measurement in Progress Clock Button Memory Access Indicator Low Battery Display 1 5V Batteries R6P LR6 o...

Страница 5: ...eries with new ones Appears if the systolic and diastolic measurements are within 10 mmHg of each other Verify that the air hose is properly connected and that the exhaust rate is between 2 and 5 mmHg...

Страница 6: ...th numeral s will blink Press the START button to advance the numbers to the correct month Press the clock button again to advance to the day setting When the numbers reflecting the day of the month b...

Страница 7: ...ose Insert the air connector plug firmly into the air socket 3 Attaching the Arm Cuff Wrap the cuff around the upper arm about 2 3 cm 1 inch above the elbow as shown Place the cuff directly against th...

Страница 8: ...usted at this time The micro pump will pressurize the cuff Note The cuff will become very tight Do not be alarmed as this is normal If the START button or clock button is pressed again during pressuri...

Страница 9: ...ss the START button to turn the power off The device will be in standby mode 6 Subsequent Measurements If a subsequent measurement is required turn off the power and turn it on again When the 0 is dis...

Страница 10: ...will reflect this stress as a higher or lower than normal blood pressure reading the pulse reading will usually be faster than normal A normal person s blood pressure varies constantly depending on w...

Страница 11: ...stored in memory Recalling Memory Data 1 To access measurements stored in memory wait until the monitor is in standby mode 2 Press and hold the START button until the display shows the most recent mea...

Страница 12: ...and permission will be given to perform various functions Measurement data of the UA 767PC can be monitored with Monitor Pro Data Analysis Software UA 767P 13 and Printer terminal TM 2480 series For d...

Страница 13: ...Blood pressure measured at a clinic or doctor s office may cause worry or apprehension and can produce an elevated reading 25 to 30 mmHg higher than that measured at home Home measurement reduces the...

Страница 14: ...tened properly Fasten the cuff correctly You moved your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfort...

Страница 15: ...ance Technical Data Type UA 767PC Measurement method Oscillometric measurement Measurement range Pressure 20 280 mmHg Pulse 40 200 beats minute Accuracy Pressure 3 mmHg or 2 whichever is greater Pulse...

Страница 16: ...ephone 1 408 263 5333 Fax 1 408 263 0119 A D INSTRUMENTS LTD Authorized Representative Established in the European Community Unit 24 26 Blacklands Way Abingdon Business Park Abingdon Oxon OX14 1DY Uni...

Отзывы: