17
9.
AUTO-TARE
The SJ-WP/-BT series has an auto-tare function to be used with the comparator mode enabled.
If the weight values are in the OK range of comparator limits and stable for a preset period of
time, the scale will automatic 1 ally tare the weight and show zero.
In some countries or areas, the auto-tare function can not be used on the Legal for Trade
models and the selection in the function settings
,
and
is not
available.
To use the auto-tare function, set the function settings below.
:
Compare all weighing data (other settings may be used depending on the
application).
:
Auto-tare function enabled.
to : Select the timing to tare automatically to avoid the wrong tare operation,
for example; too early to tare, to take a longer time to go to the next
weighing.
Normal comparion
Start with display zero after tare operation. Place or take away objects until the
comparison result will show OK. When the stable indicator is ON for a the preset period of
time specified in the function setting
, the scale will automatically tare the weight,
show zero and be ready for next weighing to repeat.
Negative comparison for take-away
(example with
)
Take-away check weighing
(negative comparison) is the
way to compare the negative
weight while taking away
objects from a container.
Set the function
together with the auto-tare
function enabled
. In this operation mode, the scale operates as "take-away the
objects"
"OK and stable"
"auto-tare"
"take-away the objects"
···.
In this setting, the polarity of LOLO, LO, HI, and HIHI limit values are ignored and the
scale shows the comparator results as below.
Note: To start the take-away check weighing, be sure to use the
TARE
switch to tare the
weight of the container filled with objects. The
ZERO
switch may zero the display, and
the scale goes below the zero point by taking out the objects. Then, the auto-tare
function does not work.
When the function "
Tares the initial (container) weight" is selected:
To start the auto-tare function, usually the container (filled with objects) will be placed on
the weighing pan and its weight must be tared using the
TARE
switch. When the
function
is selected, the scale will tare the initial (container) weight automatically.
When all load on the weighing pan is removed, the scale will return to the zero point and
the tare weight will be automatically cleared. If the scale does not return to the zero point,
press
the
switch to clear the tare weight.