![A&D MC Series Скачать руководство пользователя страница 55](http://html2.mh-extra.com/html/aandd/mc-series/mc-series_instruction-manual_3084477055.webp)
53
Filter depending on differences in the amount to deliver powdery and liquid
material
z
When the weight value is not stable even without load fluctuations
Increase the averaging range for the first moving average parameter (
f1-b
).
Increase the averaging time for the first moving average parameter (
f1-t
).
Strengthen the digital filter. (Increase the function setting “Condition (
Cond
)” parameter.)
z
When response is slow during full and medium flow
Decrease the averaging range for the first moving average parameter (
f1-b
).
Weaken the digital filter. (Decrease the function setting “Condition (
Cond
)” parameter.)
z
When response is slow during dribble flow
Decrease the averaging time for the first moving average parameter (
f1-t
).
Weaken the digital filter. (Decrease the function setting “Condition (
Cond
)” parameter.
z
To increase stability without load fluctuations
Increase the averaging range for the second moving average parameter (
f2-b
).
Increase the averaging time for the second moving average parameter (
f2-t
).
Содержание MC Series