HW-G Instruction Manual Page 34
HW-G OZIM v1a
12.1 Preparation (Setting Parameters)
Step 1
Turn off the display.
Press the
ON/OFF
switch while the
ZERO
switch
is pressed and held. The function table is displayed.
Step 2
Press the
ENTER
switch to display an item of
the comparator function (
f6
).
Step 3
Select a parameter of the full/dribble batch
function (
f6 9
) with the
^
switch.
Step 4
Press the
ENTER
switch to store the new
parameter and display an item of the full/dribble
batch sub-function (
f10
) .
Step 5
Select a parameter of the full/dribble batch sub-
function (
f10 0
~
f10 3
) with the
^
switch.
Step 6
Press the
ENTER
switch to store the new
parameter
Step 7
Press the
F
switch and the
ENTER
switch to
exit from the function table. Then the scale dis-
plays the weighing mode.