A&D HL-200i Скачать руководство пользователя страница 2

 

Weighing procedures

Weighing procedures

Weighing procedures

Weighing procedures

    

1. Turn on / off the scale

1. Turn on / off the scale

1. Turn on / off the scale

1. Turn on / off the scale    

 Press 

the 

 ON:OFF 

  key to turn on the scale. The scale displays all segments for a few 

seconds and then displays zero. 

 Press 

the 

 ON:OFF 

  key again to turn the scale off. 

 

2. Select the weighing unit

2. Select the weighing unit

2. Select the weighing unit

2. Select the weighing unit    

 Press 

the 

 UNITS 

  key to select a weighing unit from “g”, “oz”, ct (HL-200i only) , “lb-oz” 

(HL-2000i only) or “tl”. Normally the scale displays “g” when is shipped from the factory.   

To turn on with other units

, turn the scale off. Press and hold the 

 UNITS 

 key, then press 

the 

 ON:OFF 

  key. The scale will start with the next unit.   

 
 
 
 

    
3. Weighing

3. Weighing

3. Weighing

3. Weighing    

 

Verify the reading is zero. If not, press the 

 RE-ZERO 

  key to zero the display. 

 

If you use a container for weighing, place an empty container on the weighing pan and 
press the 

 RE-ZERO 

  key to zero the display. 

 

Place the objects to be weighed on the pan or in the container. When the reading 
becomes stable, the STABLE indicator 

£

 is displayed. 

 

Note

Note

Note

Note

    

Automatic power

Automatic power

Automatic power

Automatic power-

-

-

-off funct

off funct

off funct

off function

ion

ion

ion    

If the scale is left ON and the STABLE indicator 

£

 is displayed, the automatic power-off 

function turns the scale off after approximately 5 minutes.   
To disable or enable this function, press the 

 ON:OFF 

  key while pressing the 

 RE-ZERO 

 

key. When the scale is turned on, 

   XXX  

  (XXX = 1.00 etc.) is displayed and this 

function is disabled. If 

   XXX  

  is not displayed, then the function is enabled. 

 

Error message

Error message

Error message

Error message    

a     

 

Overload. Remove the objects from the pan. 

  

 

Low battery. Replace the batteries with new ones. 

 

Calibration

Calibration

Calibration

Calibration    

For information about calibration, please visit the A&D website (http://www.aandd.co.jp/). 
 
 
 

oz 

ct

tl 

g

oz

lb-oz 

tl 

HL-2000

i

 

HL-200

i

“tl” = Taiwan tael   

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN 
Telephone: [81] (3) 5391-6132      Fax: [81] (3) 5391-6148 

WM+PD4000944