A&D GX-A Series Скачать руководство пользователя страница 7

 

7

Function table display and operation keys 

 

The    indicates that the parameter displayed is in effect. 

 

Enters the function table when pressed and held in the weighing mode.   
Selects the class or item in the function table. 

 

Changes the parameter. 

 

Moves to an item in the class.   
Stores the new parameter and displays the next class.   

 

Cancels the new parameter and displays the next class when an item is displayed.   
Exits the function table and returns to the weighing mode when a class is displayed. 

 

 

Function table 

Note:  Functions available vary with the balance model. 

Class Item 

Parameter 

Description 

ba5fnc 

Environment 
Display 

Cl adj 

Clock adjustment 

Cp fnc 

Comparator 

 

pa55  d 

Password lock

 

auto Cal 

Automatic calibration

 

Refer to the GX-A/GX-F series balance instruction manual. 

 0

 

  (Same function as the    RE-ZERO    key) 

e-5 

Function 
selection 

 

(Same function as the    PRINT    key)

 

0

 

Sets the external IR switch sensitivity to HI. 

 1 

Sets the external IR switch sensitivity to MID. 

e  5  

External IR switch 

5en5 

Sensitivity 
adjustment 

Sets the external IR switch sensitivity to LOW. 

BC5 in

 *

 

Internal mass value correction 

Refer to the GX-A/GX-F series balance instruction manual.

 

* Only for the GX-A series

        

Factory setting

 

 

 

The external IR switch sensitivity adjustment function is available for balances with 
software version P-1.200 or later. 

 

www.scaleman.com offers the full line of A&D Weighing products

Buy online at https://scaleman.com/

Содержание GX-A Series

Страница 1: ...ransmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Limited The contents of this manual and the specifications of the instrume...

Страница 2: ...s the PRINT key or the RE ZERO key located on the balance Depending on the board type a dedicated foot switch an external contact input terminal terminal for actual wiring or an external IR switch is...

Страница 3: ...ff the connector that is secured to the panel with double sided tape and insert it into the socket on the option board Step 3 Attach the option board to the balance Secure the board with the two screw...

Страница 4: ...2 GXA 23 Plug External contact input terminal Compatible plug 3 5 mm 3 pole stereo plug MP 013LC or the equivalent Panel view External contact input x 2 Example of external contact input terminal Ext...

Страница 5: ...rnal IR switch in the balance function setting External IR touchless switch Sensor Place your hand about 5 cm above the sensor to activate the external IR switch Function table when the external IR to...

Страница 6: ...s shown in the diagram below The first layer is the Class and the second layer is the Item Each item stores a parameter The last displayed parameter is in effect After the PRINT key is pressed these u...

Страница 7: ...ent Display Cl adj Clock adjustment Cp fnc Comparator pa55 d Password lock auto Cal Automatic calibration Refer to the GX A GX F series balance instruction manual 0 Same function as the RE ZERO key e...

Отзывы: