Step 3  The function table stores parameters that specify how to operate the balance, and it is 

used to mointor or update those parameters.   
In the function setting, assign the PRINT or RE-ZERO key function to the external IR 
switch. The parameter that is set is stored in memory even if the AC adapter is removed 
and is retained until updated. 
The function table menu consists of two layers as shown in the diagram below. The first 
layer is the “Class” and the second layer is the “Item”. Each item stores a "parameter". 
The last displayed parameter is in effect. After the  PRINT  key is pressed, these 
updated parameters are applied to operations of the balance. 

 
 

Example of settings and menu structure 

Example: Set the function of the external IR switch to “PRINT.” 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note:  The balance may not function properly depending on the settings and the 

operating environment. Be sure to set parameters correctly. 

 
 
 
 
 
 
 
 
 

www.scaleman.com offers the full line of A&D Weighing products

Buy online at https://scaleman.com/

Содержание GX-A Series

Страница 1: ...ransmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Limited The contents of this manual and the specifications of the instrume...

Страница 2: ...s the PRINT key or the RE ZERO key located on the balance Depending on the board type a dedicated foot switch an external contact input terminal terminal for actual wiring or an external IR switch is...

Страница 3: ...ff the connector that is secured to the panel with double sided tape and insert it into the socket on the option board Step 3 Attach the option board to the balance Secure the board with the two screw...

Страница 4: ...2 GXA 23 Plug External contact input terminal Compatible plug 3 5 mm 3 pole stereo plug MP 013LC or the equivalent Panel view External contact input x 2 Example of external contact input terminal Ext...

Страница 5: ...rnal IR switch in the balance function setting External IR touchless switch Sensor Place your hand about 5 cm above the sensor to activate the external IR switch Function table when the external IR to...

Страница 6: ...s shown in the diagram below The first layer is the Class and the second layer is the Item Each item stores a parameter The last displayed parameter is in effect After the PRINT key is pressed these u...

Страница 7: ...ent Display Cl adj Clock adjustment Cp fnc Comparator pa55 d Password lock auto Cal Automatic calibration Refer to the GX A GX F series balance instruction manual 0 Same function as the RE ZERO key e...

Отзывы: