Содержание AD-8552EIP

Страница 1: ...1WMPD4004703 P EtherNet Converter EtherN t e Converter P I I AD 8552EIP AD 8552EIP...

Страница 2: ...e contents of the product specifications and this manual are subject to change without any obligation on the part of the manufacturer Under the copyright laws the software program described in this ma...

Страница 3: ...12 7 2 Factory setting 12 7 3 EtherNet IP switching settings 13 7 4 RS 232C function settings 14 7 5 Fixed decimal point function 15 8 LED status error display 16 9 Communication in EtherNet IP 17 9 1...

Страница 4: ...4212D etc it is possible to change the response speed perform calibration with an external weight and supply power from the weighing device The hooks on the back of the AD 8552EIP allow one touch mou...

Страница 5: ...rminals to connect the power cable to the terminals Splashing Water The module is not water resistant type Flammable Gas Do not install the converter where flammable gas is present Heat Radiation Of T...

Страница 6: ...manual Front panel side DIN rail mounting example DIN rail groove DIN rail width 35mm Rear panel side DIN rail hook DIN rail groove RS 232C connector Switch Pull down when removing from DIN rail Vent...

Страница 7: ...nnection with external devices Refer to 5 1 EtherNet IP specifications RS 232C interface For connection to weighing device Refer to 6 1 RS 232C specifications Communication connector RJ 45 modular con...

Страница 8: ...0 BA T Unnecessary AX KO2741 180 BA Unnecessary AX KO2741 180 GX A GX M Unnecessary AX KO2741 180 GF A GF M Unnecessary AX KO2741 180 FZi HR AZ Unnecessary AX KO2741 180 FXi HR A Unnecessary AX KO2741...

Страница 9: ...ices may not operate normally Select a switching power supply capacity of approximately 9W per unit for the dedicated power supply line for this unit If the power capacity is insufficient this unit ma...

Страница 10: ...8 A D Company Limited Device type 43 0x2B Generic Device Communication function Cyclic communication Implicit message Message communication Explicit message IP address setting method DIP switch WEB in...

Страница 11: ...ect with a cable applicable to the individual weighing device Refer to 3 2 Applicable models Connection diagram When connected to a weighing device Depending on the weighing device RXD and TXD may be...

Страница 12: ...The switch status and settings at the factory setting are as follows Refer to 7 3 EtherNet IP switching settings 7 4 RS 232C function settings for the settings that need to be changed SW 1 SW 2 SW 3 S...

Страница 13: ...ple IP ADDR Caution Please consult with your network administrator before connecting to a network Set the IP address so that it does not overlap with other devices SW 1 SW 2 IP address 0 0 Becomes the...

Страница 14: ...state CH2 RS 232C Baud rate 2400 bps 2400 bps 9600 bps 9600 bps 19200 bps 19200 bps 38400 bps 38400 bps SW 4 CH3 RS 232C Baud Rate Setting state Setting state CH4 RS 232C Baud Rate 2400 bps 2400 bps...

Страница 15: ...etting of decimal point position AD 8552EIP internal data Weighing value Instance100 byte 0 to 3 CH1 Weighing value Decimal point position Instance100 byte 6 to 7 CH1 Decimal point position 123 456g 2...

Страница 16: ...552EIP is not powered on Green lit It is working normally Green blink Not initialized Red lit An unrecoverable failure has occurred Red blink A recoverable failure has occurred NS Network Status Off T...

Страница 17: ...lue to be used refer to the instruction manual of the individual weighing device 9 1 Preparing for communication 1 Set the following setting items so that the RS 232C of the weighing instrument and AD...

Страница 18: ...5 CH4 byte 6 7 The following command is output to the weighing device connected to CH1 4 1 The AD 8552EIP outputs each command to the connected instrument when a 1 is written 2 The operation differs...

Страница 19: ...haracteristics UInt16 Response characteristics 30 31 CH2 Adjustment status UInt16 Adjustment status 32 35 CH2 Adjustment weight value Int32 Adjustment weight value 2 36 39 CH3 Weighing value Int32 Wei...

Страница 20: ...e is interrupted for 2 seconds or more and rezero or calibration is in progress 3 Rezeroing flag 1 Rezero processing in progress 4 No function 5 Adjustment in progress flag 1 Adjustment in progress 6...

Страница 21: ...x0000 Initial value 0x0001 Waiting for zero point weighing 0x0002 Weighing the zero point 0x0003 Waiting for adjustment weight to be weighed 0x0004 Weighing adjustment weight 0x0005 Sensitivity adjust...

Страница 22: ...between the weighing value and the weighing value status information may differ depending on the update timing so the weighing value status cannot be determined accurately If you change the decimal p...

Страница 23: ...CH1 Adjustment status Wait until 0x0005 12 Replaces the weight 13 Confirms the transition to the weighing state Refer to the corresponding data layout Byte 0 3 CH1 Weighing value Wait until 0x00000000...

Страница 24: ...e weighing value is unstable Sensitivity adjustment completed 0x0005 is not entered and it switches automatically to weighing mode Also if the weighing value is not appropriate Sensitivity adjustment...

Страница 25: ...afari 10 1 Preparing for communication 1 Prepare in the same way as 9 1 Preparation for communication 9 EtherNet IP 2 Enter the IP address of the AD 8552EIP in the address bar of your browser 3 Press...

Страница 26: ...display switching button 10 3 Weighing Device Operation Screen connected to each channel is displayed HOME button 10 2 HOME display is displayed Key switch Operates the weighing device 1 The key swit...

Страница 27: ...fore connecting to the network Set the IP address so that it does not overlap with other devices Network setting screen Name Setting value setting range Description IP address 0 0 0 0 to 255 255 255 2...

Страница 28: ...r PLC has timed out Is the EtherNet IP communication cable broken Is the scanner turned on IP address cannot be changed Turn the power of the AD 8552EIP off and then on again When the power is turned...

Страница 29: ...stralia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bldg 33 Gukjegeumyung ro 6 gil Yeongdeungpo gu Seoul 07331 Korea 82 2 780 4101 82 2 78...

Отзывы: