58
Control I/O Connection
The specifications are common for both the standard control I/O and the AD-8118C-02 control I/O.
Input circuit Output circuit
The input and output circuits are shown above. Be careful of the minimum applicable load when
connecting the input. Receive the output by auxiliary relay, solid-state relay (SSR), etc. Use a relay with a
coil voltage of 12 to 24VDC and a current of 50mA or less. (Omron MY Series DC24, etc.)
When the environment is noisy, connect the cable shield to frame ground.
Unless otherwise specified, the input is operated by connecting an input to input common and when the
output is operated, the output transistor is turned ON. Inputs other than code input are pulse inputs. Input a
pulse width of at least 200 msec.
Code input is negative logic.
View from the rear panel
+V
Relay or open collector
Approx. 5mA
or
Input common
AD-8118C
12
11 10 9 8 7 6 5 4 3 2 1
A
B
+V
+V
or
Output common
Содержание AD-8118C