background image

 

Operators and Maintenance Manual 

 

Measuring module

 

EMS DAQ R02.01

 

Page 

6/18

 

 

Copyright: 

Auto & Aero Technologies Sp. z o.o. 

Mazowiecka 10/5, 20-723 Lublin, Poland  

 email: [email protected] 

  

www.aatech.pl 

 

 

using non-original parts and subassemblies voids the warranty, relieves the 
supplier from any liability, making the device lose the status of the product 
of Auto & Aero Technologies Sp. z o.o. with all the resulting consequences. 

2.  Handling in transport and storage 

1.

 

The  EMS  DAQ  R02.01  module  is  bubble-wrapped  to  protect  it 
against  vibration  and  other  physical  damage,  and  packed  in  a 
cardboard box together with the warranty card.  

2.

 

The display must be stored and transported assuring that:  

o

 

the ambient temperature stays in the range of 10 

 40

°C

 

o

 

the ambient relative humidity stays in the range of 10

90 %, 

safe from condensation. 

3.

 

The display should be protected from water.  

3.  Installation  

3.1.  Environmental specifications 

The EMS DAQ R02.01 module has been designed to be installed in engine 
compartment  of  ultralight  aircrafts  of  ceiling  not  exceeding  3  000  m 
(10 000 ft). Acceptable ranges of operating parameters are listed below: 

 

Operating temperature: 

 

-20 

o

 50 

o

 

Short-term operating temperature:  -25 

o

 60 

o

 

Humidity:   

 

 

 95 %, no condensation; 

 

Ambient air pressure:  

 

45 

 105 kPa; 

 

Vibrations:  

 

<5 g at frequencies below 150 Hz; 

Содержание EMS DAQ R02.01

Страница 1: ...asuring module EMS DAQ R02 01 Page 1 18 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Operators and Maintenance Manual Measuring mod...

Страница 2: ...ort and storage 6 3 Installation 6 3 1 Environmental specifications 6 3 2 Dimensions 7 3 3 Mounting 7 3 4 Power and wiring 7 4 Operation and maintenance 10 4 1 Measured signals 10 4 2 Signal analysis...

Страница 3: ...an element of the Integrated Avionics System that measures the following engine operation parameters a Engine speed b Rotor speed c Inlet air pressure d Inlet air temperature e Oil pressure f Oil temp...

Страница 4: ...3 Inlet air pressure Bosch 0 281 002 976 4 Oil pressure BRP 456180 1 5 Oil temperature BRP TEMPERATURE SENSOR 965531 1 6 Cylinder head temperature BRP TEMPERATURE SENSOR 965531 1 2 sensors 7 Exhaust g...

Страница 5: ...e it This manual does not replace instructions on installation maintenance and operation of this device in a particular airframe these are to be prepared by the user Instructing the pilots and mainten...

Страница 6: ...e and packed in a cardboard box together with the warranty card 2 The display must be stored and transported assuring that o the ambient temperature stays in the range of 10 40 C o the ambient relativ...

Страница 7: ...EMS DAQ R02 01 module outline drawing 3 3 Mounting The EMS DAQ R02 01 Module should be installed vertically using mounting holes shown in Figure 2 The module should be located in a part of the engine...

Страница 8: ...n Figure 3 The power supply requires 0 75 mm2 wires Sensor connection requires 0 5 mm2 wires Thermocouple wires should be attached directly to the module s connector Data bus RS0 RS1 RS2 requires twis...

Страница 9: ...Maintenance Manual Measuring module EMS DAQ R02 01 Page 9 18 Copyright Auto Aero Technologies Sp z o o Mazowiecka 10 5 20 723 Lublin Poland email info aatech pl www aatech pl Fig 1 EMS DAQ R02 01 Modu...

Страница 10: ...b 2 Signals processed by EMS DAQ R02 01 Module No Parameter Measurement range Accuracy 1 Engine speed 0 6500 rpm 10 rpm 2 Rotor speed 0 500 rpm 1 rpm 3 Inlet air temperature 0 3 4 bar abs 0 1 bar 4 Oi...

Страница 11: ...hold crossings recorded by EMS DAQ R02 01 Module No Signal Threshold levels 1 Engine speed 5500 rpm if present for more than 5 min 2 Engine speed 5800 rpm 3 Rotor speed 450 rpm 4 Inlet air pressure 46...

Страница 12: ...on of a parameter assuming values from a specific range The data are recorded separately for each parameter and for each of four value ranges Information on the statistics is downloadable by means of...

Страница 13: ...from 900 to 925 above 925 11 Cylinder head temperature sensor 2 C from 850 to 875 from 875 to 900 from 900 to 925 above 925 12 Linear acceleration g 1 from 2 to 4 from 4 to 8 from 8 to 12 above 12 1 i...

Страница 14: ...display data 2 After 100 hours of flight a Check the instrument s electric connections Remove the lid of the monitor casing Check if wires sit firmly in screw connection terminal blocks Check for wire...

Страница 15: ...onnection ensure that your power supply is capable of supplying at least 8 volts and no more than 30 V data bus connection RS0 Fig 3 Indication of no connection to measurement module a If the system d...

Страница 16: ...the bulletins published by the Manufacturer The updates can be introduced by means of service software provided by the Manufacturer and the dedicated diagnostic interface 5 7 Spare parts The module do...

Страница 17: ...is lodged within months 7 to 12 after date of purchase the warranty extends for a further 6 months after completion of the warranty repair 7 This warranty does not cover failures due to a mechanical...

Страница 18: ...o Aero Technologies Sp z o o and shall not without prior written permission of Auto Aero Technologies Sp z o o be disclosed in whole or in part to third parties This statement shall be included on any...

Отзывы: