DESCRIPTION

This Signal Conditioner  allows analog voltage levels to be set and read
via its RS-232 serial port.  Commands are provided to perform various
functions: an analog output, read an analog input, verify the communica-
tions link, programming, and enter calibration mode.

(c)

FEATURES

The 

I/O

is capable of operating in a voltage output mode or a current out-

put mode.  When operating in the voltage mode the analog input and out-
put range is 0.00 to 5.00 volts.  In the current mode the analog input and
output range is 4.00 to 20.0 milliamps.   See Selecting the Operating Mode.

(d)

SPECIFICATIONS

d.1

General Attributes

INPUT AND OUTPUT ANALOG RANGE:

0 - 5 Vdc  or  4 - 20 mA, jumpers selectable.

INPUT OVERVOLTAGE/OVERCORRECT PROTECTION:

15 Vdc, 50 mA.

MINIMUM OUTPUT VOLTAGE COMPLIANCE IN 4-20 mA MODE:

8 Vdc.

MAXIMUM INPUT VOLTAGE DROP IN 4-20 mA MODE:

5 Vdc.

POWER SUPPLY REQUIREMENTS: 

10 to 30 Vdc, less than 0.75 watts (OPTIONAL).

OPERATING TEMPERATURE RANGE: 

F

C to 70 

F

C.

ALTITUDE:

to 10,000 feet.

DIGITAL VOLTAGE STANDARD:

RS-232 or RS-485 (not galvanically isolated).

COMMUNICATIONS PARAMETERS: 

8 bits, one stop bit no parity (N,8,1). 

RS-232 COMMON MODE CAPABILITY: 

+10 volts.

RESOLUTION:

10 bits (0.1%).

DATA FORMAT: 

ASCII.

DATA TRANSFER RATE: 

300 baud to 9600 baud.

MODULE CONNECTION METHOD:

Pinch Type terminals.

2

Содержание i/o 232

Страница 1: ...COMMUNICATIONS TERMINALS OPERATING MANUAL I O SIGNAL CONDITIONER Technical Data Sheet No TD9809M Rev F Date of Issue December 9 2009 7 77172 727 132 844 278 03 48 473 204 51 73 343 384 55 89 843 206...

Страница 2: ...E Compliance e ELECTRICAL CONNECTIONS e 1 Connector Pin Assignments e 2 Jumper Assignments f PROGRAMMING g CALIBRATION PROCEDURES g 1 Equipment Required for Calibration g 2 Calibration h SELECTING THE...

Страница 3: ...ing List Please report any shortages promptly a 3 Returning Merchandise for Repair Please contact the customer service representative of your distributor or Aalborg if you purchased your I O directly...

Страница 4: ...s See Selecting the Operating Mode d SPECIFICATIONS d 1 General Attributes INPUT AND OUTPUT ANALOG RANGE 0 5 Vdc or 4 20 mA jumpers selectable INPUT OVERVOLTAGE OVERCORRECT PROTECTION 15 Vdc 50 mA MIN...

Страница 5: ...n allowing the stripped wire to be inserted Remove the screwdriver and the connection is made Pin 1 Analog input from sensor IN Pin 2 Analog input from sensor IN Pin 3 Analog output to sensor OUT Pin...

Страница 6: ...A mode f PROGRAMMING Programming the module allows the user to set the communications baud rate module address and whether to use error checking Note that the address is included only for compatibilit...

Страница 7: ...Equipment Required for Calibration You will need a 3 1 2 digit DMM set to the selected analog output range see Selecting Operating Mode a power supply and a dumb terminal or PC running a communication...

Страница 8: ...alog output crc optional error checking characters the crc is composed of two ASCII characters CR ASCII carriage return character There are no spaces in the transmitted command spaces are inserted her...

Страница 9: ...mmand M x crc CR The reply format is Bad Command crc CR If the command is not received no response is sent Host T Command T or t This command tells the I O Module to transmit its current reading Up to...

Страница 10: ...nd understood The reply format is OK crc CR Host C Command C or c This command tells the I O Module to enter calibration mode Calibration instructions are sent to the terminal display See Calibrating...

Страница 11: ...tly Is the power supply correctly selected according to requirements When several meters are used a power supply with appropriate current rating should be selected Were the connector pinouts matched p...

Страница 12: ...10 APPENDIX 1 Components Diagram NOTE Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice For certified dimensions please contact Aalborg7...

Страница 13: ...OTE Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice For certified dimensions please contact Aalborg7 3 000 76 2 4 166 105 8 1 750 44 5 1...

Страница 14: ...2 6 1 GFM HOST PC RS232 PORT Fig 1 Connection diagram GFM to I O232 5 9 4 8 3 7 2 6 1 COMMON 10 30 VDC RX TX OUT OUT IN IN 8 7 6 5 4 3 2 1 SIGNAL CONDITIONER 8 15 7 14 6 13 5 12 4 11 3 10 2 9 1 5 9 4...

Страница 15: ...the liability of Aalborg and the provisions of this warranty Defective products will be repaired or replaced solely at the discretion of Aalborg at no charge Shipping charges are borne by the custome...

Отзывы: