15
RotoClone LVN
© 2015 American Air Filter Company, Inc. Any use of the text or images
this document contains, without permission of American Air Filter
Company, Inc., is prohibited. RotoClone, AAF, REDClean, REDFiltration,
and Reliable Efficient Durable are registered trademarks of American Air
Filter Company, Inc. d/b/a AAF International.
9
ASSEMBLY AND INSTALLATION
9.1
Introduction
Safe and efficient operation of the RotoClone LVN depends on proper
installation.
AAF recommends that the ductwork going into the collector be as straight as
possible, with at least 5 diameters of straight run recommended.
Authorities with jurisdiction should be consulted before installing the
RotoClone LVN to insure local installation laws, codes, regulations and procedures
are followed.
A qualified installation and service agent must complete installation and
service of the dust collector and equipment.
Ensure all covers from shipping and loose materials are removed from the
collector before installation. Failure to do so can result in failure of the dust
collector.
Ensure the hardware on the dust collector assemblies are properly installed
and tight before installation.
9.2
Assembling and installing the structure
9.2.1
All Arrangements
1.
Set RotoClone on foundation and adjust base until unit is level. Place
spirit level on the leveling strips welded on two or more sides of the
hopper. Use care in leveling both directions as the operation of the
RotoClone depends on the accuracy of the leveling function.
Note:
This level can be checked by filling the unit with water until the level
reaches the entering edge (Figure 1) of the impeller. This entering edge
should be level with the water along its entire length with maximum
variation of 1⁄16" plus or minus.
9.2.2
Lubrication
All motor bearings are ball bearings and packed with grease before leaving
the factory. Do not add more grease during installation.