SAAFShield
®
Detecting Unit
6.0 Connecting to the Reading Unit (RU)
When inserting QCMs for the first time, the RU will
automatically default to the ‘“Edit QCM Info” window
and force the user to enter information regarding QCM
parameters. Be prepared to enter this information when
installing a new QCM. See brochure GPF-3-117.
The Information that will be needed when initializing the
Gold, Silver, and Copper QCMs is:
• Site ID
• Room ID
• Detecting Unit ID
• Detecting Unit installation location information (upstream,
downstream, or in-room)
The Initialization frequency and install date and time will be
automatically recorded by the RU.
SAAFShield
®
Reading Unit
7.0 Spare Parts List
It is recommended that the following spare parts be stored
at the installation site for replacement purposes. Consult
with your AAF Flanders representative to determine actual
quantities required. Minimum recommended quantities are
provided in the table below.
To order replacement parts call:
1-800-223-2003.
9920 Corporate Campus Drive, Suite 2200, Louisville, KY 40223-5690
888.223.2003 Fax 888.223.6500 | aafintl.com
AAF Flanders has a policy of continuous product
research and improvement and reserves the right to
change design and specifications without notice.
ISO Certified Firm
©2017 AAF International and its affiliated companies.
GPF-3-116B
01/17
SAAFShield
®
is a registered trademark of
AAF International in the U.S. and other countries.
AAF Flanders Description
Recommended
Part Number
Spares
392-803-010 Silver Crystal QCM
One full replacement set
of each type included in
the system.
392-803-011
Gold Crystal QCM
One full replacement set
of each type included in
the system.
392-803-012
Copper
One full replacement set
Crystal QCM
of each type included in
the system.