background image

 

T H E   W O R L D   L E A D E R   I N   C L E A N   A I R   S O L U T I O N S

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

SAAFShield

®

Detecting Unit Real-Time Reactivity Monitor

Table of Contents

1.0  Principles of Operations
2.0  Components
3.0  Installing Quartz Crystal  

 

Microbalance (QCMs)

4.0  Installing the Detecting Unit
5.0  Troubleshooting
6.0  Connecting to the Reading Unit
7.0   Spare Parts List

Read and Save These Instructions!

Note: 1. 

Read and understand all operating instructions before  

 

  installing and using the SAAFShield Detecting Unit Real-Time  

 

  Reactivity Monitor.

 2. 

Save this manual for future reference.

This instruction manual provides important information on the installation 

and operation of the SAAFShield Detecting Unit Real-Time Reactivity 

Monitor. These instructions must be carefully followed in order to operate the 

unit safely and correctly. If there are any questions regarding the use or care 

of this unit, please contact AAF Flanders at 888-223-2003 or by email at 

[email protected] for assistance. 

1.0 Principles of Operation 

The SAAFShield Detecting Unit is the non-powered, sensing side of the 

SAAFShield system that utilizes Quartz Crystal Microbalance (QCM)  

technology to measure metal corrosion due to reactions with the  

environment. The SAAFShield Detecting Unit works in combination with  

the SAAFShield Reading Unit as part of a system that monitors atmospheric 

corrosion in real time or on a periodic basis. 
The SAAFShield Detecting Unit’s oscillator Printed Circuit Board (PCB)  

consists of specially marked tracking where electromagnetic induction 

effects are significantly reduced in order to produce the most stable and 

accurate frequency reading. As the metal-coated QCM corrodes, the  

frequency of oscillation changes. The Detecting Unit has built-in  

non-offgassing Ethylene Vinyl Acetate (EVA) foam spacers to prevent  

unwanted movement of the QCMs within the enclosure.