13
© 2016 American Air Filter Company, Inc. Any use of the text or images
this document contains, without permission of American Air Filter
Company, Inc., is prohibited. FabriPulse and AAF are registered
trademarks of American Air Filter Company, Inc. d/b/a AAF
International.
In the case of hazardous dust, consult your local authorities, laws, codes, or
regulations for the location of the unit.
8.2
Anchoring
The FabriPulse BinVent is designed to be mounted on top of silos or
pneumatic transfer points. Mounting flanges with holes drilled to match customer
specifications are provided. Refer to the specific FabriPulse BinVent collector
drawing for bolt pattern and location.
9
ASSEMBLY AND INSTALLATION
9.1
Introduction
Safe and efficient operation of the FabriPulse BinVent depends on proper
installation.
Authorities with jurisdiction should be consulted before installing the
FabriPulse Binvent to ensure local installation laws, codes, regulations and
procedures are followed.
A qualified installation and service agent must complete installation and
service of the dust collector and equipment.
Ensure all covers from shipping and loose materials are removed from the
collector before installation. Failure to do so can result in failure of the dust collector.
Ensure the hardware on the dust collector assemblies are properly installed
and tight before installation.
Apply silicone sealant to the bottom of the collector flange before mounting to
the silo or intended location. Ensure sealant circles around each bolt hole. Lift the
collector using its lifting lugs and lower into position at the installation location so
that the holes in the matching flanges correctly align.
9.2
Filter Installation
Cartridge filters for the FabriPulse BinVent are shipped separately, and must
be installed before operating the unit. To install the cartridges, follow the
instructions as follows:
1.
To open the lid of the collector, disengage the 2 hold down latches on the
front of the unit, and lift up on the handle provided.