background image

FRONT VIEW

TOP VIEW

BOTTOM VIEW

SIDE VIEW

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

E

E

F

F

G960-11-S

ML / GJD

16-6-2016

DRAWN BY:

APPROVED:

REVISION:

AAF International B.V.
P.O.Box 60, 7800 AB  Emmen
The Netherlands

This drawing is property of AAF and is loaned subject to conditions that shall not be
reproduced, copied loaned or submitted to outside parties without our written consent 

AAF Filter Fan Unit 612 SL

TITLE:

0

DATE :

SCALE:

PROJECT   :

UNIT  :

2015026

A2

1  OF 2 

1 : 6

- ELECTRONIC DOCUMENT -

PRINTED COPIES

 ARE UNCONTROLLED

PRODUCT OWNER:

FM:  

o

AAF EUROPE

DRAWING. NO.:

mm

SHEET:

UL:  

o

 

 

 

DO NOT SCALE DRAWING

1162

- 1

1

+

2

0

0

-

1

1

+

2

4

2

562

- 1

1

+

150

HOUSING MATERIAL
FAN ACCESS TYPE

FAN (EC-TYPE) SIZE

FILTER FAN UNIT SPECIFICATIONS

(ROOM SIDE CHANGE)

ALUMINUM

BOTTOM

Ø310 mm

OPTIONAL PRE-FILTER SIZE

DIMENSIONS

1162 x 562 x 200 mm

W x H =  494 x 494 x D mm (20" x 20")

REQUIRED FILTER SIZE = FFU SIZE + 8 mm

REQUIRED FILTER SIZE

W x H x D =  1170 x 570 x D mm

NOMINAL AIR FLOW @ 0,45 m/s

1080 m³/h

478

4

7

8

PRE-MOUNTED SCREWS (8x) FOR PRE-FILTER FRAME

"GND"-CONNECTION 

REMOVABLE FAN UNIT

CONNECTION BOX

(FOR MAINS & DATA)

ID-LABEL

SHEET 2: FILTER FAN UNIT W/ MOUNTED FRAME FOR PRE-FILTER

TEST PORT

REVISION HISTORY

REV

DATE

DESCRIPTION

0

16-06-2016

INITIAL RELEASE

239

2

3

9

Содержание AstroFan Base

Страница 1: ...AstroFan Base Instruction Manual...

Страница 2: ...2...

Страница 3: ...Instructions 4 Transport Storage 5 Mechanical Installation 8 Network Connections 9 Operating Conditions 9 Operating Commissioning 9 Maintenance 10 Fault Finding 10 Manufacturer s Declaration of Confor...

Страница 4: ...e inlet grill and terminal HEPA ULPA filter must not be removed or by passed neither are they to be rendered inoperative The AAF AstroFan FFU is a self contained ceiling filter fan unit designed for u...

Страница 5: ...f the AstroFan fan top to carefully position the fan top onto the adapter frame Do not apply force The unit rests on the gasket of the adapter and seals by its own weight Mechanical fixtures are prefe...

Страница 6: ...fe edge into the gel seal Take care not to apply force to the filter media 5 Ensure all 4 strips are installed fully and the filter is firmly secured 4 Slide the support strips into the room side chan...

Страница 7: ...uilt in electronics connected with a bus line to the control unit or a PC operated visualized control All fans are dynamically balanced at two levels in accordance with VDI 2060 or DIN ISO 1940 Sectio...

Страница 8: ...n the electrical wiring can be connected at the terminal box on top of the housing Options When a pre filter is provided place pre filter into holding frame fan protection grill Pre filters do not req...

Страница 9: ...the lifetime lubrication will provide a working life of 30 40 000 hours After depletion of the lubricant the entire bearing needs to be replaced Access to the fan and motor is gained from the top by l...

Страница 10: ...error than this is a connection error Check if all connectors are properly connected Check the wiring especially of the RS485 network Check if the CCU AstroDrive has been connected correctly Check if...

Страница 11: ...Style code Size Part Number 1 2 3 4 5 Note The filter test report is attached to each individual AstroCel HEPA ULPA filter Please retain the report s and file together with this operating manual PLEAS...

Страница 12: ...94300 Vincennes Phone 33 1 43 98 42 23 sales france aafeurope com www aafeurope fr Greece AAF Environmental Control Epe Ifaistou Kikladon 15354 Glika Nera Tel 30 210 6632015 Greece aafeurope com www a...

Страница 13: ...M o AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING 1162 1 1 350 1 1 392 562 1 1 150 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE CHANGE ALUMINUM...

Страница 14: ...subject to conditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent AAF Filter Fan Unit 612 TITLE B DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2...

Страница 15: ...EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING 1162 1 1 350 1 1 392 862 1 1 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE CHANGE ALUMINUM BOTTOM 400...

Страница 16: ...conditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent Filter Fan Unit 912 TITLE B DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 6 ELECTRONIC...

Страница 17: ...NG NO mm SHEET UL o DO NOT SCALE DRAWING 1162 1 1 350 1 1 392 1162 1 1 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE CHANGE ALUMINUM BOTTOM 400 mm OPTIONAL...

Страница 18: ...onditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent AAF Filter Fan Unit 1212 TITLE B DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 8 ELECTRON...

Страница 19: ...AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE CHANGE ALUMINUM BOTTOM 310 mm OPTIONAL PRE FILTER S...

Страница 20: ...o conditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent Filter Fan Unit 69 TITLE B DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 6 ELECTRONIC...

Страница 21: ...ER FM o AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE CHANGE ALUMINUM BOTTOM 310 mm OPTIONAL PRE F...

Страница 22: ...s that shall not be reproduced copied loaned or submitted to outside parties without our written consent Filter Fan Unit 66 TITLE B DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 5 ELECTRONIC DOCUMENT PR...

Страница 23: ...UMENT PRINTED COPIES ARE UNCONTROLLED PRODUCT OWNER FM o AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING 1162 1 1 350 1 1 392 562 1 1 150 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FIL...

Страница 24: ...ons that shall not be reproduced copied loaned or submitted to outside parties without our written consent AAF Filter Fan Unit 612 K Box TITLE 0 DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 6 ELECTRONI...

Страница 25: ...OLLED PRODUCT OWNER FM o AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING 862 1 1 350 1 1 392 862 1 1 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS ROOM SIDE...

Страница 26: ...conditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent AAF Filter Fan Unit 99 TITLE 0 DATE SCALE PROJECT UNIT 2015026 A2 2 OF 2 1 6 ELECTRONI...

Страница 27: ...ONTROLLED PRODUCT OWNER FM o AAF EUROPE DRAWING NO mm SHEET UL o DO NOT SCALE DRAWING 1162 1 1 200 1 1 242 562 1 1 150 HOUSING MATERIAL FAN ACCESS TYPE FAN EC TYPE SIZE FILTER FAN UNIT SPECIFICATIONS...

Страница 28: ...subject to conditions that shall not be reproduced copied loaned or submitted to outside parties without our written consent AAF Filter Fan Unit 612 SL TITLE 0 DATE SCALE PROJECT UNIT 2015026 A2 2 OF...

Отзывы: