for motor, fan, and ancillary component service. Side access is required for shaker
motor and control access.
Explosion vents, if furnished, are located on the side opposite the access
door. It is recommended per NFPA that the vent(s) be ducted outside and away
from any area containing personnel or equipment. Duct flanges can be match
drilled to the collector housing wall, but they must be supported separately from
the unit.
The unit can be located indoors or outdoors. Rain hoods are included in the
design of the ArrestAll to prevent water from gathering on the top of the door
gasket.
8.2
Foundations
The foundation must be level and adequate to support the collector’s
operating weight including dust load, discharge devices, wind load if applicable,
plus any auxiliary equipment if applicable.
8.3
Anchoring
The AR ArrestAll collector is designed for installation on a flat surface. Units
must be suitably anchored.
Anchor holes are provided at the base of the support legs on the funnel
bottom units (Figure 3), and anchor clips are provided on the cart bottom (Figure
4). Flat bottom units can be installed by drilling holes in the bottom of the units.
Holes drilled in the flat bottom base should be gasketed or caulked to prevent air
bypass.
Figure 3. Anchoring – Funnel Bottom
Figure 4. Anchoring – Cart Bottom