Installation Instructions
Ozone Generator Placement
• Install ozone generator in a clean, dry area with good ventilation.
• Place the MP unit above any water tank level.
• If pressure is lost in the venturi vacuum and the unit is below water tank level, gravity will
pull water through the ozone output hose and enter the ozone generator.
• Please look at the provided drawing for more information (Figure 1.2).
• Place stone no more than 18 inches deep.
NOTE:
Place the ozone generator in room temperatures below 130 degrees F. Prolonged
exposure to extreme temperatures will void the warranty.
Venturi Installation
• Install the venturi injector with the bypass valve on water recirculation pipeline (Figure
1.1).
• The arrow on venturi should be set in the same direction as water flow.
• Turn water pump on and close the bypass valve until a vacuum is created at the venturi
input.
NOTE:
Use a gauge to check vacuum -2 to -3 PSI (-0.14 to -0.21 bars) or place finger over
end of venturi valve to feel the vacuum. At this point, the air is injected into the water line.
This is observed by air bubbles inside the water tank.
NOTE:
The water tank requires an exhaust to the outside of the building with an ozone
destructor to remove excessive ozone.
Main Power
• Use the power cable provided to connect the MP-8000 to a properly rated and grounded
receptacle.
• If the MP Series is used where water is present, a ground fault circuit
interrupter must protect the circuit.