background image

2 | 

P a g e

 

A 1 0   H a r m o n y

T M

  C o n t r o l l e r   2 0 0 0   I n s t a l l a t i o n   G u i d e

 

 

© 2018 A10 Networks, Inc. Confidential and Proprietary - All Rights Reserved

 

Information in this document is subject to change without notice.

 

Patent Protection 

 

A10 Networks products are protected by patents in the U.S. and elsewhere. The following website is provided to 

satisfy the virtual patent marking provisions of various jurisdictions including the virtual patent marking provisions of 
the America Invents Act. A10 Networks' products, including all Thunder Series products, are protected by one or 
more of U.S. patents and patents pending listed at:

 

https://www.a10networks.com/company/legal-notices/a10-virtual-patent-marking

.

 

Trademarks

 

The A10 logo, A10 Harmony, A10 Lightning, A10 Networks, A10 Thunder, aCloud, ACOS, Affinity, aFleX, aFlow, 

aGalaxy, aGAPI, aVCS, AX, aXAPI, IDsentrie, IP-to-ID, SSL Insight, SSLi, Thunder, Thunder TPS, UASG, and vThunder 
are trademarks or registered trademarks of A10 Networks, Inc.  in the United States and other countries.  All other 
trademarks are property of their respective owners.

 

Confidentiality

 

This document contains confidential materials proprietary to A10 Networks, Inc. This document and information and 

ideas herein may not be disclosed, copied, rep

ro

duced or distributed to anyone outside A10 Networks, Inc. without 

prior written consent of A10 Networks, Inc. 

 

A10 Networks Inc. Software License and End User Agreement

 

Software for all A10 Networks products contains trade secrets of A10 Networks and its subsidiaries and Customer 

agrees to treat Software as confidential information. 

 

Anyone who uses the Software does so only in compliance with the terms of the End User License Agreement 

(EULA), provided later in this document or available separately. Customer shall not:

 

1.

 

reverse engineer, reverse compile, reverse de-assemble or otherwise translate the Software by any means

 

2.

 

sublicense, rent or lease the Software.

 

Disclaimer

 

This document does not create any express or implied warranty about A10 Networks or about its products or 

services, including but not limited to fitness for a particular use and non-infringement. A10 Networks has made 
reasonable efforts to verify that the information contained herein is accurate, but A10 Networks assumes no 
responsibility for its use. All information is provided "as-is." The product specifications and features described in this 
publication are based on the latest information available; however, specifications are subject to change without 
notice, and certain features may not be available upon initial product release. Contact A10 Networks for current 
information regarding its products o

r services. A10 Networks’ products and services are subject to A10 Networks’ 

standard terms and conditions.

 

Environmental Considerations

 

Some electronic components may possibly contain dangerous substances. For information on specific component 

types, please contact the manufacturer of that component. Always consult local authorities for regulations regarding 
proper disposal of electronic components in your area.

 

Further Information

 

For additional information about A10 products, terms and conditions of delivery, and pricing, contact your nearest 

A10 Networks location, which can be found by visiting 

www.a10networks.com

 

Содержание Harmony Controller 2000

Страница 1: ...1 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 2: ...and Customer agrees to treat Software as confidential information Anyone who uses the Software does so only in compliance with the terms of the End User License Agreement EULA provided later in this...

Страница 3: ...tion 8 Power On 9 Power Supply Unit Installation 10 Overview 11 DC Power Supply Installation 12 Power Supply Hot Swap 13 Removing a Power Supply 13 Inserting a Power Supply 14 Fan Hot Swap 16 Fan Modu...

Страница 4: ...4 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 5: ...ning a damaged box before inspection by the shipper will void any potential shipping claims CAUTION Do not attempt to install or operate damaged equipment As with any electrical equipment personal inj...

Страница 6: ...k mount installation Specifications for the equipment rack are listed in Table 2 Rack mount installation instructions are available in Rack Mount Kit Installation Other Requirements Other equipment ne...

Страница 7: ...nterface Console 1 Ethernet interface Mgmt for remotely managing the device over the network FIGURE 1 Harmony Controller 2000 Interface Locations and Numbers Using the Interface Connections To begin u...

Страница 8: ...ss Off No power access HDD Green On HDD under access Off No Data access Installation Table 2 describes the minimum requirements for your equipment rack Verify these specifications against your equipme...

Страница 9: ...he power switch NOTE Power OFF To perform a graceful shutdown use the shutdown command in the CLI If you made any changes to the device configuration you will be prompted to save your configuration in...

Страница 10: ...nstallation Power Supply Hot Swap CAUTION Do not attempt to install or operate damaged equipment As with any electrical equipment personal injury or damage to other equipment can result from commissio...

Страница 11: ...you must disconnect it from the power source This is required regardless of whether the power supply is in standby mode or powered on mode Likewise when installing a power supply insert the power sup...

Страница 12: ...Refer to the following instructions and figures for this procedure Also see figures on previous page 1 Attach Green wire to ground for both ends 2 Attach BLACK 48 volt wire to 48 volt pin on DC power...

Страница 13: ...i d e Power Supply Hot Swap Follow the directions in the following sections to remove and insert a power supply unit FIGURE 7 Power Supply Hot Swap Removing a Power Supply To remove a power supply 1 P...

Страница 14: ...0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e Inserting a Power Supply To insert a power supply 1 Push the power supply into the slot 2 Plug the power cable into th...

Страница 15: ...15 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 16: ...The following topics are covered Fan Module Location and Fan Numbers Removing a Fan Module Inserting a Fan Module Fan Module Location and Fan Numbers The location and number of each fan is shown in Fi...

Страница 17: ...i o n G u i d e FIGURE 9 Removing the Top Panel to Access Fan Modules 2 Hold both screws then pull them outward to slide the top panel out 3 Lift to remove the top panel CAUTION Operation on or for t...

Страница 18: ...dule to remove it 5 Remove the fan module Inserting a Fan Module Follow the steps below in order to insert a fan module 1 Insert the fan module into the appropriate location 2 Tighten the two screws t...

Страница 19: ...19 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 20: ...ing Ear Bracket Installation Ear Bracket Installation This section describes how to install the ear brackets used for rack mount installation Front Mount Installation Front Mount Installation This sec...

Страница 21: ...fasten the bracket using the provided screws Make sure the fit is snug FIGURE 12 Alignment of Brackets Over Screw Holes 3 Repeat these steps to attach the other bracket 4 Attach the device to the fron...

Страница 22: ...22 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e FIGURE 14 Verification of Screws...

Страница 23: ...23 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 24: ...0W AC Power Supply Specifications Table 3 lists the specifications for the AC power supply TABLE 3 750W AC Power Supply Product Specification Item Specification Part Number ASK PS 040 Power Supply Out...

Страница 25: ...25 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 26: ...26 P a g e A 1 0 H a r m o n y T M C o n t r o l l e r 2 0 0 0 I n s t a l l a t i o n G u i d e...

Страница 27: ...3...

Отзывы: