Figure 13-7 Camera Parameters Settings
Step 3 Select the
Camera
from the drop-down list.
Step 4 (Optional) Switch the 4 MP or 5 MP signal from the
Signal Switch
drop-down list. 4 MP
25/30 fps and 5 MP 20 fps are selectable. The 4 MP 25 fps and 4 MP 30 fps signals are
self-adaptive for the camera.
Step 5 (Optional) Check the checkbox of
Enable Defog
to enable the defog function of the selected
camera. And set the
Defog Level
from 1 to 4.
Step 6 (Optional) Adjust the other camera parameters including
Day to Night Sensitivity
,
Night to
Day Sensitivity
and
IR Light Brightness
for the analog cameras. You can also click
Default
to
set the parameters to the default settings.
Step 7 (Optional) Click
Copy
to copy the parameters of the current camera to other analog
cameras.
Step 8 Click
Apply
to save the settings.
The camera parameters settings is only applicable for ananlog cameras.
The 4 MP/5 MP Signal Switch, Defog, Day to Night Sensitivity, Night to Day Sensitivity and IR
Light Brightness functions must be supported by the connected analog camera. You cannot
set the parameters if the connected analog camera does not support them or there is no
video signal.
The parameters are saved to the connected analog camera and are not saved to the DVR.
The default value of Day to Night Sensitivity, Night to Day Sensitivity and IR Light Brightness
is 5. The effective value ranges from 1 to 9.
If you exit from the interface and enter it again, the parameters displayed are those you
have set the last time.
The DVR connects to the analog camera via coaxitron and there is no response mechanism.
Even if the coaxitron is abnormal, the parameters are still displayed to be set successfully.