www.a-ts.cn A-TS Technology RT10
66
allocation error
Err 34
Flash reads CRC
error
Flash reads CRC error
Err 35
Motor adaptation
error
Non-adaptive motor
Err 36
Watchdog error
Driver internal watchdog error
Err 37
Motor initial zero
lock error
Zero position lock error
Err 38
External braking
resistor is wrong
The resistance of the external braking resistor is
less than the minimum allowable value
Err 51
Multi-turn data
exceeds the set
value
Multi-turn data exceeds the set value
Err 52
Main power supply
under voltage alarm
In the enabled state, the bus voltage is lower
than 245V
Err 53
AC main power
supply failure/ is off
The power supply cable L1, L2, L3 is powered
down
Err 54
AC main power
supply phase loss
The power supply cable L1, L2, L3 is phase
loss
Err 55
Dynamic braking
overcurrent
Dynamic braking overcurrent fault
Err 56
Internal D5V
undervoltage
The voltage supplied to the control board is less
than 5 V
Err 62
Motor speed out of
control
There is large difference between command
speed and actual speed.