Installation and Operating Instructions 
UPS Edition One 6kVA, 10kVA

1. Important safety instructions

Be sure to observe all warnings and operating instructions in this manual. Keep this 
manual in a safe place and read the following instructions carefully before installing and 
operating the unit.
The system may only be installed and connected by trained electricians in compliance 
with the relevant safety regulations.
The operating instructions must be read and understood by all personnel and specialists 
who are responsible for the operation, cleaning as well as disposal of the unit.
Dangerous voltages and high temperatures are present inside the UPS. Observe the 
local safety instructions and the corresponding laws during installation, operation and 
maintenance, otherwise personal injury or damage to the unit may occur. The safety 
instructions in this manual serve as a supplement to the local safety instructions.
Our company accepts no liability for damage caused by failure to observe the safety 
instructions.
The UPS as well as the associated components may only be used for the purpose 
corresponding to their design - to supply electrical devices (230 V AC) which in total do 
not exceed the rated power. Any other use or use beyond this is considered improper and 
may result in personal injury, property damage and/or damage to equipment
Please note the following:

■ 

  

Don’t use the UPS when the actual load exceeds the rated load.

■ 

  

Internal short circuit of the UPS will cause electric shock or fire. So don’t place 
the containers equipped with liquid on the top of the UPS so as not to cause 
danger of electric shock.

■ 

  

Do not place the UPS in a location with high temperature or humidity, 
corrosive gases or much dust.

■ 

  

Ensure good air circulation between the inlet opening at the front and the 
outlet opening at the back to prevent excessive heating.

■ 

  

Avoid direct sunlight or the proximity of heat-emitting objects.

■ 

  

If smoke appears on the UPS, please switch off the power as soon as possible 
and contact your supplier.

■ 

  

Work on accumulators is to be carried out and supervised only by personnel 
with appropriate expertise in the required safety rules. Unauthorised persons 
must be kept away from accumulators.

■ 

  

There are high capacity batteries in the UPS. Do not open or destroy them. 
The released electrolyte is dangerous for people and the environment. There is 
a risk of explosion. If internal maintenance or battery replacement is required, 
contact your supplier.

Содержание 9885107

Страница 1: ...ty VA Article number a TroniX UPS Edition One 6kVA 6000 9885107 a TroniX UPS Edition One 10kVA 10000 9885108 06 2021 Seite 1 ONLINE UPS Installation and Operating Instructions a TroniX UPS Edition One...

Страница 2: ...evel With the a Tronix Series Edition One your installations are safely protected from power supply problems and the functionality of your equipment is maintained Read carefully before use Read this m...

Страница 3: ...nd turn off UPS 13 4 1 1 Start up operation 13 4 1 2 Turn off operation 13 4 2 Faceplate display 14 4 2 1 Faceplate display illumination 14 4 2 2 LCD display 15 4 3 Parameter settings 17 4 3 1 Mode se...

Страница 4: ...sign to supply electrical devices 230 V AC which in total do not exceed the rated power Any other use or use beyond this is considered improper and may result in personal injury property damage and or...

Страница 5: ...Batteries must never be brought into contact with heat sources or flames Do not attempt to dispose of the batteries by burning them Defective accumulators must be disposed of in an environmentally fri...

Страница 6: ...Warnings and notes are indicated by the corresponding symbols pictograms and must be observed WARNING Warning of dangerous electrical voltage General warning of danger points Warning when handling ac...

Страница 7: ...2 Product Introduction 2 1 Product view UPS 6 10kVA 6 10kVA Front Panel view 6 10kVA Rear Panel view without maintenance 1 USB to connect the UPS to a PC 2 EPO for emergency shutdown 3 Parallel port...

Страница 8: ...ne 6kVA 10kVA 6 10kVA Rear Panel view with maintenance 1 USB to connect the UPS to a PC 2 EPO for emergency shutdown 3 Parallel port 1 4 Parallel port 2 5 Intelligent slot 6 RS232 7 Input switch 8 Ter...

Страница 9: ...t UPS Principle Diagram 1 Mains input 2 Rectifier 3 Inverter 4 Bypass switch 5 Bypass 6 Charger 7 Battery bank 8 Extended Battery Pack optional 9 UPS output 2 3 Product Category USV Type Remark Standa...

Страница 10: ...lations All environmental and operating conditions requirements specified in the technical data must be complied with in order to ensure the correct functioning of the UPS The unit may only be set up...

Страница 11: ...responding input and output terminals The protective earth conductor refers to the cable connection between the parts that consume electrical current and the earth cable The cable diameter of the eart...

Страница 12: ...e event of a supply emergency the software ensures that all data is saved and the units are shut down properly Communication port SNMP Optional Optionally the UPS can be equipped with an SNMP communic...

Страница 13: ...LCD display The LED display of the UPS shows the current status of the UPS 4 1 2 Turn off operation 1 Turn off the UPS in line mode without batteries a Press and hold the ESC OFF button for 2 seconds...

Страница 14: ...10kVA 4 2 Faceplate display 4 2 1 Faceplate display illumination Overview of the operating panel of the UPS 1 INVERTER LED 2 BATTERY LED 3 BYPASS LED 4 ALARM LED 5 LCD display 6 UP button 7 DOWN butt...

Страница 15: ...uency 02 Output Voltage Frequency 03 Bat Voltage Current pos 04 Bat Voltage Current neg 05 Temp Ambient temperature 06 Load Load 07 Bus voltage Bus voltage 08 UEA Version of software 09 Model Model Wh...

Страница 16: ...ns UPS Edition One 6kVA 10kVA 2 Press the DOWN button and the UPS goes to the next page each time as shown below 2 Input voltage 3 Output voltage 4 Bat voltage positive 5 Bat voltage negative 6 Load 7...

Страница 17: ...setting parameter Press Enter On to enter the value setting status press the UP or DOWN key to set the value Press the ON key to confirm Press and hold the DOWN key until the setting parameter is exit...

Страница 18: ...mode setting or the frequency setting NOTE When powered by inverter it is necessary to turn off the inverter before setting voltage and frequency level 4 3 3 Output frequency setting Frequency settin...

Страница 19: ...sing UP or DOWN for a long time the battery capacity can be quickly reduced Use the UP DOWN keys to go to the frequency setting or to set the battery quantity 4 3 5 Battery quantity setting Battery qu...

Страница 20: ...ltage upper limit is 5 10 15 or 25 25 only for 220V output Use the UP DOWN key to access the battery quantity setting or to set the lower limit of the bypass voltage 4 3 7 Bypass Volt Lo setting Bypas...

Страница 21: ...he selection includes ON and OFF NOTE ON mute OFF no mute Press the UP or DOWN button to stop muting and save the muting status and to switch to the lower bypass voltage limit setting or the battery s...

Страница 22: ...itch to battery mode every 30 days The battery self test time is 10 seconds If you select ON2 the UPS can automatically switch to battery mode every 30 days The battery self test time is 10 minutes If...

Страница 23: ...the UP DOWN buttons takes you to the battery self test setting or parallel quantity setting NOTE No parallel cable can be connected when setting the parallel parameters 4 3 11 Parallel quantity settin...

Страница 24: ...ep continuously Fault LED lit 2 Inverter fault Including Inverter bridge is shorted Beep continuously Fault LED lit 3 Inverter Thyristor short Beep continuously Fault LED lit 4 Inverter Thyristor brok...

Страница 25: ...LED blinking 32 Overload Once per second INV or BPS blinking 33 No battery Once per second BATTERY blinking 34 Battery under voltage Once per second BATTERY blinking 35 Battery low prewarning Once pe...

Страница 26: ...attery is completely discharged until the under voltage protection switches off It has to be fully recharged immediately 2 In areas with high temperatures the batteries should be manually charged and...

Страница 27: ...disconnected Contact your supplier Mains normal but UPS has no input UPS input breaker open circuit Press the breaker for reset Short back up time Battery not fully charged Keep UPS connecting with m...

Страница 28: ...20 x 9 20 x 9 Charging current max Default 1 Output Voltage V AC 208 220 230 240 Frequency Hz Mains mode 10 of nominal voltage Battery mode 50 60 0 1 Hz Waveform Pure Sinewave Crest factor 3 1 Others...

Отзывы: