background image

 

APL-9 SERIES 

Stainless Steel Limit Switch 

Installation & Maintenance Manual  

 

 

May 16, 2016 

www.atcontrols.com 

Iom08074 

 

9. 

Tools  

  1 Set Metric Allen Key (Hex Wrench)  

  Set Screw Drivers  

  1 Set Metric Wrench  

  1 Wire Stripper long Nose  

  1 Needle nose plier  

  1 Multi Meter (AC, DC, Resistance)  

  1 4-20mA Loop Calibrator (if applicable 16 adapted) 

  

10. 

Installation and Maintenance Tips  

For any installation and maintenance work, the following should be observed:  

 Caution: 

 

A regular inspection and maintenance performed by qualified and trained personnel. 

  

When working in potentially explosive areas, observe the standard EN 60079-14 “Electrical 

Installations in Hazardous Areas”. 

 

Work at the open actuator under voltage must only be performed if it is assured that for the 

duration of the work there is no danger of explosion. 

 

Observe additional national regulations.  

10.1. Check the limit switch box visually. Ensure that no outside damage or changes are visible.  
10.2  Check electric connecting cables and ensure they are without damage and are wired correctly.  
10.3. Cable entries, cable glands, plugs etc. have to be checked for correct tightness and sealing.   
10.4. Check whether enclosure connections are fastened correctly.  
10.5. Take care of possible discoloration of the terminals and wires.  
10.6. Check the enclosure joints for dirt and corrosion.  
10.7. Ensure that all housing covers are handled carefully and that the seals are checked.  
10.8. If defects which affect the safety are detected during maintenance, repair measures have to be 

taken immediately.  

10.9. Any kind of surface coating for the mating surfaces between housing and cover is not permitted.  
10.10. When exchanging parts, seals etc. only original TRIAC Controls spare parts shall be used.  

 

 
 

A-T Controls product, when properly selected, is designed to perform its intended function safely during its useful life.  However, the purchaser or user of A-

T Controls products should be aware that A-T Controls products might be used in numerous applications under a wide variety of industrial service 

conditions.  Although A-T Controls can provide general guidelines, it cannot provide specific data and warnings for all possible applications.  The purchaser 

/ user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of A-T Controls 

products.  The user should read and understand the installation operation maintenance (IOM) instructions included with the product, and train its employees 

and contractors in the safe use of A-T Controls products in connection with the specific application. 

 

While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only. Because A-

T Controls is continually improving and upgrading its product design, the specifications, dimensions and information contained in this literature are subject 

to change without notice.  Should any question arise concerning these specifications, the purchaser/user should contact A-T Controls.   

 

For product specifications go to 

http://download.a-tcontrols.com/

  

 

A-T Controls, Inc. • 9955 International Boulevard, Cincinnati, OH 45246 • Phone: (513) 530-5175 • Fax: (513) 247-5462 • 

www.atcontrols.com

 

 

 

 

Содержание TRIAC APL-9 Series

Страница 1: ...APL 9 SERIES Stainless Steel Limit Switch Installation Maintenance Manual 1 May 16 2016 www atcontrols com Iom08074 APL 9 Series Valve Position Monitor Installation Operation Maintenance Manual...

Страница 2: ...ls com Iom08074 Contents 1 General 3 2 Standard specification 3 3 Standard Features 4 4 Installation 5 4 1 Mounting bracket 5 4 2 Mounting limit switch box 5 4 3 Cam setting 6 4 4 Wiring 6 5 Maintenan...

Страница 3: ...terminal strip switch assembly and integral mounting bracket Quick set cam allows for a quick and simple hand operation in the setting of switches 2 Standard specification Model APL 9 Electrical Ratin...

Страница 4: ...APL 9 SERIES Stainless Steel Limit Switch Installation Maintenance Manual 4 May 16 2016 www atcontrols com Iom08074 3 Standard Features...

Страница 5: ...cket feet at desired height 20mm 30mm 40mm or 50mm Tighten the screws using a proper tool 30mm bracket height 4 2 Mounting limit switch box Caution Do not attempt to work on limit switch box without f...

Страница 6: ...itch is activated Release the cam so it fits back over the cam gear 4 4 Wiring Danger HAZARDOUS VOLTAGE No electrical power should be connected until all wiring and limit switch adjustments have been...

Страница 7: ...APL 9 SERIES Stainless Steel Limit Switch Installation Maintenance Manual 7 May 16 2016 www atcontrols com Iom08074 2 SPDT 4 SPDT 2 NAMUR Output P F NJ2 V3 N...

Страница 8: ...pen close cycle Inspect identification labels for wear and replace if necessary Warning Treat cover with care Mating surfaces must not be damaged in any way 6 Inspection 6 1 The limit switch box shoul...

Страница 9: ...be taken immediately 10 9 Any kind of surface coating for the mating surfaces between housing and cover is not permitted 10 10 When exchanging parts seals etc only original TRIAC Controls spare parts...

Отзывы: