background image

14

SR703 | SR707 AMPLIFICADOR DE POTENCIA PARA CONTRATISTAS

Español

ESPECIFICACIONES

SR703

SR707

Salida de Potencia Directa

8 ohms

120 Watts x 2

240 Watts x 2

4 ohms

200 Watts x 2

400 Watts x 2

2 ohms,1kHz,1%THD

300 Watts x 2

550 Watts x 2

Mono Bridge 8 ohms, 1kHz, 1%THD

420 Watts

850 Watts

Mono Bridge 4 ohms, 1kHz, 1%THD

540 Watts

1100 Watts

Salida de Voltaje Aislada Constante

200V o 140V Bridge

300 Watts

700 Watts

100V o 70V

150 Watts x 2

350 Watts x 2

25V

120 Watts x 2

280 Watts x 2

Respuesta en Frecuencia

Salidas Directas (+0/-2dB)

50Hz - 50kHz

50Hz - 50kHz

Salidas Aisladas (+0/-2dB)

50Hz - 16kHz

50Hz - 16kHz

Distorsión Armónica Total

<0,05

<0,05

Sensibilidad (salida completa)

1,02V

1,02V

Aumento de la Señal (GAIN) de Voltaje

28dB

28dB

Impedancia de Entrada

Balanceada/Desbalanceada

20k/10k ohm

20k/10k ohm

Factor de Amortiguación (Damping)

>200 (entrada directa)

>200 (entrada directa)

Relación S/R

Menor a 100dB debajo de la salida medida (20Hz-20kHz)

Circuitos de Protección

Protección de offset de voltaje de salida

Protección de disipador de calor de sobrecalentamiento

Protección de sobrecalentamiento de transformador

Protección de corto de carga

Protección de encendido/apagado

Controles

Panel Frontal

Botón de encendido

Panel de Dorso

Controles de Ganancia Ch1 & Ch2 (41 clicks); selector Paralelo/Estéreo/Bridge

Conectores

Entrada

XLR jack x2, Regletas de conexión x1

Salida

Regletas de conexión x2; binding post resistente

Cooling

Un ventilador de velocidad dual

Indicadores

Clip: Rojo

Señal: Verde

Protección: Amarillo

Encendido: Rojo

Dimensiones (AlxAnxP)

132 x 480 x 395mm

(5�2” x 19” x 15�6”)

132 x 480 x 395mm

(5�2” x 19” x 15�6”)

Peso Neto

20 Kg (44�1 lbs)

24�7 Kg (54�6 lbs)

Содержание SR707

Страница 1: ...User s Manual Manual del Usuario Contractor Power Amplifier Amplificador de Potencia Para Contratistas SR703 SR707...

Страница 2: ...CAUCIONES 10 ACERCA DE ESTE MANUAL 10 PANEL FRONTAL 10 PANEL POSTERIOR 11 CONEXIONES DE ENTRADA 12 CONEXIONES DE SALIDA 12 ESPECIFICACIONES 14 DIMENSIONS DIMENSIONES 15 Asystems reserves the right to...

Страница 3: ...apparatus during lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power...

Страница 4: ...e cover is in place over the output terminals and do not touch any exposed speaker wiring while the amplifier is operating ABOUT THIS MANUAL Please be reminded that a power amplifier is a high current...

Страница 5: ...another SR or other amplifier 9 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the amplifiers In Parallel operation one signal is...

Страница 6: ...he amplifier is turned off before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Direct Low Impedance Output connection bridge mono...

Страница 7: ...er to the Rear Panel section on page 5 Low Impedance and Distributed Speakers If your application calls for connection of an 8 ohm speaker and a distributed line to the same amplifier channel the SR70...

Страница 8: ...n 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat sink overheat protection Transformer overheat protection Load shorting protection Power on off protectio...

Страница 9: ...9 SR703 SR707 AMPLIFICADOR DE POTENCIA PARA CONTRATISTAS Espa ol...

Страница 10: ...s a la salida Para evitar descargas el ctricas aseg rese de que la cubierta este encima de los terminales de salida y no toque ning n cable de altavoz que este expuesto mientras el amplificador este o...

Страница 11: ...SR o a cualquier otro amplificador 9 Selector Est reo Paralelo Bridge En operaci n est reo dos se ales separadas ser n transmitidas por los canales 1 y 2 de los amplificadores En operaci n en Paralelo...

Страница 12: ...or este apagado antes de cambiar cualquier conexi n de salida Liberal los tornillos de los terminales inserte las conexiones de los cables debajo de los tornillos Apriete firmemente los tornillos de l...

Страница 13: ...er n ajustarse independientemente Por favor referirse a la descripci n previa del Panel Trasero Altavoces Distribuidos y de Baja Impedancia en los Amplificadores SR703 y SR707 Si sus aplicaciones nece...

Страница 14: ...Impedancia de Entrada Balanceada Desbalanceada 20k 10k ohm 20k 10k ohm Factor de Amortiguaci n Damping 200 entrada directa 200 entrada directa Relaci n S R Menor a 100dB debajo de la salida medida 20...

Страница 15: ...15 SR703 SR707 CONTRACTOR AMPLIFIER Appendix DIMENSIONS DIMENSIONES Measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas 132 5 2 480 19...

Страница 16: ...www asystems sys com...

Отзывы: