6.3
Long periods of non-use may lead to the formation of lime scale
deposits. Working through the hole on the
rear, RELEASE the motor using a screwdriver
(for models with this feature). Then remove
the screwdriver and proceed with the restart
operations.
- Except for the Extreme -
6.4
Clean the nozzle with the tool provided.
Remove the lance from the gun; remove any dirt from the
nozzle hole and rinse.
4.3
Connect the high-pressure hose to the water (OUTLET) on the
cleaner.
4.4
Connect the water supply hose.
(not supplied) to the water (INLET)
of the cleaner. The supply hose
must have an internal diameter of at
least 13 mm (1/2 in.) and must be
reinforced. The water supply must
be at least equal to the cleaner
delivery capacity.
The intake water temperature must NOT exceed 60° C
(122°F). The water supply pressure must NOT exceed 10
BAR (145 PSI).
4.4.1
CAUTION! The cleaner must only be used with clean
water; use of unfi ltered water or corrosive chemicals will
damage the cleaner.
4.5
Turn the motor switch to the “0” position.
4.6
Check that the electrical supply voltage and frequency (Volts/
Hz) correspond those specifi ed on the cleaner data plate.
4.6.1
If the motor stops and fails to restart, wait 2 to 3 minutes before
restarting. THERMAL CUTOUT TRIPPED AND MUST COOL
BEFORE RESTARTING.
AR610 models: These cleaners are packaged with a red shipping plug in the
pump crankcase, this red plug must be removed and the black dipstick cap
installed.
5. U
SE
5.1
Turn on the water supply to FULL fl ow.
5.2
Release the safety catch, then
press the trigger for a few
seconds to allow air to escape
and to discharge residual
pressure in the pipes.