13
IOM D-070-P
•
Visually check the condition of the Rolling Seal [1]. If any cracks or tears are found, remove it from the Float [2] and replace it.
•
When required, replace the seal by inserting a new Rolling Seal into its designated groove. Please note: side [1] of the groove is
slightly wider than the other [2]; therefore the seal can be inserted only from the wider side of the groove.
•
Take a new Rolling Seal Assembly and dip the tail end into the liquid soap solution [3]
•
Pay attention to the correct position and direction and insert the tail end of the Rolling Seal Assembly into the groove on the
Float [4].
•
Gently pull the Rolling Seal Assembly until it is partially inserted into the Float grove. Use the 4.5mm Roll Pin Punch to push the
Rolling Seal Assembly to the middle of the Float [5] and align the middle of the Rolling Seal Assembly tail with the midline of the
Float [6].
1
2
2
1
3
4