INSTALLING YOUR WATER HEATER

Consumer Information

This water heater should be installed in accordance with 
the local code authority having jurisdiction, the power 
company or electric utility, and this installation manual. 
In the absence of local code requirements, follow the 
regulations set forth in the latest edition of The National 
Electric Code, NFPA 70. This is available from the 
following:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
American National Standards Institute
1430 Broadway
New York, NY  10018
Check your phone listings for the local authorities having 
jurisdiction over your installation.

Consumer Responsibilities

This manual has been prepared to acquaint you with the 
installation, operation and maintenance of your electric heat 
pump water heater and to provide important safety information 
in these areas. 
We urge you to read all of the instructions thoroughly before 
attempting the installation or operation of this water heater. 
This manual should be kept for future reference.
The manufacturer of this water heater will not be liable for any 
damages caused by failure to comply with the installation and 
operating instructions outlined in this manual. 
If you lack the necessary skills required to properly install this 
water heater or you have dif

fi

 culty following the directions, you 

should not proceed but have a quali

fi

 ed person perform the 

installation of this water heater.

Examples of a qualified person include: licensed plumbers, 
authorized electric company personnel, and authorized 
service personnel.

Massachusetts code requires this water heater to be installed 
in accordance with Massachusetts 248-CMR 2.00: State 
Plumbing Code and 248-CMR 5.00.  
A data plate identifying your water heater can be found 
adjacent to the upper element door. When referring to your 
water heater always have the information listed on the data 
plate readily available, to include the model and serial number.
Retain your original receipt as proof of purchase.

Basic Operation Fundamentals

The Heat Pump Water Heater (HPWH) is an integrated 
heat pump water heater unit, having an 850 watt 
compressor and external coil heat exchanger with backup 
electric elements (See Figure 1). When in Ef

fi

 ciency Mode 

the heat pump draws heat from the ambient air in the room 
and transfers it to the water in the tank through the coil 
heat exchanger. While in Electric Mode the water heater 
functions like a standard electric water heater, relying on 
the electric elements to heat the water. A Hybrid Mode is 
available that relies primarily on the heat pump to heat 

the water while the electric elements only function during 
high demand periods. (See “Adjusting the User Interface 
Module/ Operational Mode” section).  The more often 
the unit operates using the heat pump, rather than the 
elements, the more ef

fi

 cient the unit will be.

The 80-gallon tank capacity of this water heater is intended 
to take optimal advantage of the heat pump’s capability to 
heat water for large families or those having higher than 
normal hot water requirements.  This high capacity will 
enable the unit to operate in the maximum ef

fi

 ciency mode 

more often than other models having lower capacity.
The HPWH uses about half the electricity of a comparably 
sized conventional electric water heater when operating 
in the Ef

fi

 ciency Mode, and provides up to ½ ton cooling 

capacity and dehumidi

fi

 cation.  It is designed for indoor, 

residential applications for installation in a basement, 
garage or utility room (See “Location Requirements” 
section).

Ambient Air

Cool/Dehumidified Air

Heat Exchanger
(Heat Transfer Coils)

Upper Element

(4500 Watt)

Lower Element

(2000 Watt)

Water Tank

Jacket

Figure 1
Heat Pump Water Heater Basic Operation

Heat Pump

(Transfers heat 

from ambient 

air to Heat 

Exchanger)

Unpacking the Water Heater

WARNING

Excessive Weight Hazard

Use two or more people to move and install 
water heater.

Failure to do so can result in back or

 

other injury.

Removing Packaging Materials

IMPORTANT:

 Do not remove, cover or deface any 

permanent instructions, labels, or the data label from either 
the outside of the water heater or on the inside of water 
heater panels.

Содержание Voltex Hybrid Electric PHPT-80

Страница 1: ...Information 3 Consumer Responsibilities 3 Unpacking Instructions 3 4 Location Requirements 4 Water System Piping 5 6 Temperature Pressure Relief Valve 7 8 Electrical Requirements 8 9 Installation Che...

Страница 2: ...extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appli...

Страница 3: ...ipt as proof of purchase Basic Operation Fundamentals The Heat Pump Water Heater HPWH is an integrated heat pump water heater unit having an 850 watt compressor and external coil heat exchanger with b...

Страница 4: ...ead all instructions before attempting to assemble and install this product After installation dispose of recycle all packaging materials Location Requirements Site location Select a location near the...

Страница 5: ...own in Figure 4 If installing the water heater in a closed water system 5 install an expansion tank in the cold water line as specified under Closed System Thermal Expansion Install a shut off valve i...

Страница 6: ...es Use appropriate primer and glue to cement the condensate drain lines to the heat pump drain pan NOTE The heat pump drain pan is ABS and the two condensate drain pipes should be PVC If a condensate...

Страница 7: ...ve and the end of the discharge line Shall terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at...

Страница 8: ...led with water and all air is purged from the tank before making any electrical connections See Draining and Flushing Section Turn off power to the electrical wiring for the water heater at 2 the circ...

Страница 9: ...Press the power button to turn the water heater on 8 and select the desired operational mode After about 8 minutes the heat pump will turn on Test the operation of the shut off switch by unplugging 9...

Страница 10: ...free of leaks Heater completely filled with water See Water Piping System section Closed system pressure buildup precautions installed See Closed System Thermal Expansion section Mixing valve when app...

Страница 11: ...ing in the red reset button located on the ECO block If the ECO continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F...

Страница 12: ...the User Interface are touch sensitive and require only a light touch to actuate EFFICIENCY Efficiency Mode Is the most energy efficient mode This mode uses the heat pump to heat water in the tank The...

Страница 13: ...rd These noises are common and may result from the following Normal expansion and contraction of metal parts 1 during periods of heat up and cool down Sediment buildup on or around the elements could...

Страница 14: ...ORTANT Do not turn on power to the water heater unless it is completely filled with water To ensure that the tank is full open a hot water faucet and allow the water to run until the air is purged and...

Страница 15: ...ir Filter Remove and inspect clean if needed and reinstall Condensate drain pan and condensate lines The lower metal drain pan for standing water which may indicate a clogged condensate drain pan cond...

Страница 16: ...OPEN OR AD ERROR 1 Upper Temperature Sensor is not functioning Contact a qualified person to service the unit 1 LOWER TEMP SENSOR SHORT OR OPEN OR AD ERROR 1 Lower Temperature Sensor is not functionin...

Страница 17: ...is at the top Insulate exposed piping 5 Repair hot water leaks 6 Call qualified person for service 7 Drain and flush tank Water conditioning may 8 be necessary to minimize build up HIGH OPERATION COS...

Страница 18: ...4 Drain Valve 15 Protective Plastic Cover 16 ECO Cover 17 Control Board 18 Relay 19 EPS Cover 20 Ambient Coil Discharge Temperature Sensor 21 Upper Lower Tank Temperature Sensor 22 Run Capacitor 23 Co...

Страница 19: ...19 NOTES...

Страница 20: ...20 Copyright 2010 A O Smith Corporation All rights reserved...