12-1. Diagnosis using the remote controller
< Individual unit>
1. Press the "HOT" button and the "COLD" button simultaneously for
at least 5 seconds to enter “Diagnostic mode”.
2. "1" will be displayed on the remote controller. (See Fig. 1)
In this condition, “1” means the left side combustion section and
“2” means the right side combustion section.
Scroll up or down to the needed combustion section by pressing
the “HOT” or “COLD” buttons.
3. When the desired combustion section is fixed by pressing the
“INFO” button (Fig.2 shows mode #2 the right side combustion
section is being fixed.), scroll up or down to the needed
information (mode #) of the combustion section by pressing the
“HOT” or “COLD” buttons.
4. Press the “INFO” button to fix the mode #, and information to
which the mode # correlates to will display on the remote
controller. (Fig.3 shows mode #31 is being fixed.) When
selecting information, please refer to the table on p.50 for the
proper mode #.
5. The information of the mode # will display on the remote controller. (Fig.4)
6. When the “ON/OFF” button is pressed or 5 minutes have elapsed without pressing any buttons, the
display will return to normal.