T-M50 / T-M50 ASME Service manual
Ver. 1.05
44
CONFIDENTIAL
Error Code
Malfunction description
Cancellation method
Pump failure
Turn off the power
Diagnosis
Checkpoint
631
1 Check whether the pump connected to central computer board works
properly.
Error Code
Malfunction description
Cancellation method
Water control valve fault
(Flow adjustment function)
Turn off the power or water supply
Diagnosis
Checkpoint
651
1 Left and/or Right PCB and flow adjustment valve fault
(Refer to section 10-9 & 10-14)
Visual inspection of Water control valve: connection/breakage of wires,
motor drive locked due to scale buildup, and/or water leakage.
Normal: 13.0 to 16 VDC between (blue-brown)
Normal: ON:12.5 to 16.0 V / OFF: 0 to 1 V
Normal: 1 V Less than (0˚ position)
Visual inspection PCB: connection/breakage of wires and/or burn marks on
the computer board.
J
Error Code
Malfunction description
Cancellation method
Water control valve fault
(Bypass valve function)
Turn off the power or water supply
Diagnosis
Checkpoint
661
1 Left and/or Right PCB and bypass valve fault
(Refer to section 10-9 & 10-14)
Visual inspection of Water control valve: connection/breakage of wires,
motor drive locked due to scale buildup, and/or water leakage.
Normal: 13.0 to 16 VDC between (blue-brown)
Normal: ON:12.5 to 16.0 VDC / OFF: 0 to 1 V
Normal: 1 V Less than (0˚ position)
Visual inspection PCB: connection/breakage of wires and/or burn marks on
the computer board.
J
Error Code
Malfunction description
Cancellation method
External fan motor failure
Turn off the power
Diagnosis
Checkpoint
681
1 Check whether the external fan motor connected to central computer board
works properly.