240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial
Ver. 1.00
CONFIDENTIAL
Outdoor models of 240 (T-H3J) / 340 (T-H3S) : Propane
Level
Elevation
Output
reduction
Fan motor
speed change
DIPswitch settings
No.3
No.4
No.5
0
0 (DEFAULT)
N/A
N/A
OFF
OFF
OFF
1
Up to
2,000 ft
N/A
3 %
OFF
ON
OFF
2
Up to
4,000 ft
-11 %
7 %
OFF
OFF
ON
3
Up to
6,000 ft
-14 %
9 %
ON
OFF
ON
4*
Consult our Technical Services Department
Special function
N/A
-7 %
ON
OFF
OFF
*If the abnormal sound problem presists even with a "Level 3" setting, please contact our Technical Service
Department for advice. Note that there are many high risks associated with manually changing manifold pressure.
Outdoor models of 240 (T-H3J) / 340 (T-H3S) : Natural gas
Level
Elevation
Output
reduction
Fan motor
speed change
DIPswitch settings
No.3
No.4
No.5
0
0 (DEFAULT)
N/A
N/A
OFF
OFF
OFF
1
Up to
2,000 ft
N/A
6 %
OFF
ON
OFF
2
Up to
4,000 ft
-9 %
14 %
OFF
OFF
ON
3
Up to
6,000 ft
-12 %
18 %
ON
OFF
ON
4*
Consult our Technical Services Department
Special function
N/A
-7 %
ON
OFF
OFF
*If the abnormal sound problem presists even with a "Level 3" setting, please contact our Technical Service
Department for advice. Note that there are many high risks associated with manually changing manifold pressure.