63
Page
240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial
Ver. 1.00
CONFIDENTIAL
12-2. Verifying functionality of computer board
A. How to check if the computer board works properly
1. Check the power ON-OFF switch
of the water heater.
The factory setting is ON position.
3. If the computer board works properly, the green LED on the computer board will light up.
B. Data backup function of the temperature remote controller
240 (T-H3J) / 340 (T-H3S) models
computer board
Green LED
540 (T-H3) models
computer board
Green LED
Power ON-OFF switch
Temperature controller
Temperature
remote controller
OR
2. Turn on the ON/OFF button of
either the temperature controller or
the temperature remote controller.
Do not exchange both the controller and the computer board simultaneously.
The temperature remote controller has a backup function which allow the data was stored in the
computer, can be transferred to the temperature remote controller. When the computer board is
replaced, the stored data is transferred automatically to a new computer board by the
temperature remote controller.
REMOTE
CONTROLLER
AC120V
OFF
ON
Power ON-OFF switch