background image

MODEL

NUMBER

FIRST

HOUR

RATING

GALLON

CAPACITY

RECOVERY

90°F RISE

PER HOUR

ENERGY

FACTOR

BTU INPUT

PER HOUR

NATURAL

R

VALUE

A

B

C

D

E

F

APPROX.

SHIPPING

WEIGHT

HOT CONNECTION

COLD
CONNECTION

ANODE ROD*

E

*Location for optional top-mounted 
  T&P Valve if ordered from factory.

B

A

F

D

1/2" GAS
CONNECTION

T&P VALVE

C

(FVIR models only)

FVIR design meets 

American National Standards Institute standards 

(ANSI Z21.10.1 - CSA 4.1) that deal with the accidental or 
unintended ignition of flammable vapors, such as those emitted by gasoline. 

FVIR gas water heaters feature a sealed combustion chamber with air intake 
screen and a fireproof Corderite flame arrestor built into the water heater base. 
In addition, a thermal cutoff (TCO) device, integral with the thermocouple, is 
designed to shut off gas flow to the burner and pilot if poor combustion is detected.

Flammable Vapor Ignition Resistant (FVIR)
Water Heaters

If flammable vapors
accidentally enter the
combustion chamber,
the Corderite flame
arrestor is designed
so flames burn off 
the top surface and
cannot escape down
through the arrestor.

A.

Easy-to-light

piezo ignitor

B.

View port for easy 
burner inspection
inside sealed 
combustion chamber

Recovery capacity based on actual performance tests. Water Connections – 1" on 75-gallon model, 1-1/4" on 100-gallon model, 3⁄4" on all other models.
* Not equipped with FVIR Technology. 75 and 100-gallon models have factory-installed (non-heat trap) nipples, 75-gallon model has 80% efficiency,  
998 BTU/hr. standby loss; 100-gallon model has 80% efficiency, 1146 BTU/hr. standby loss.

† Propane Gas –  GCVT-40: 45,000 BTU input; GCVT-50: 45,000 BTU input; GCVX-50: 55,000 BTU input; GCV-65: 62,500 BTU input. 

For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XCVT-40), or change “F” to “P” in model number  (example: PCG-75).

DIMENSIONS (INCHES)

DRAFT

HOOD

OUTLET

(LBS)

(GPH)

www.hotwater.com

For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

Residential Gas Water Heaters

Revised April 2011

Page 2 of 2

AOSRG45400

The FVIR Series 100 models are certified from sea level to 7,700 ft. elevations. The FVIR Series 300 models are certified from sea level to 10,100 ft. elevations. 
For high attitude versions of the 75 & 100-gallon models add SMR “S19”

®

GCVT-40

75

40

51

0.60

50,000

16

61-3/4 58-1/4

20

13-1/4

8

51-3/4

4

138

300

SERIES

GCVT-50

90

48

51

0.58

50,000

8

60-7/8 56-1/2

20

13-3/8

8

50-3/8

4

GCVX-50

93

50

67

0.58

65,000

16

63-7/8 59-1/2

22

15-1/2

8

54-1/8

4

GCV-65

116

65

67

0.57

65,000

16

65

60

24

15-1/2

8

54-1/4

4

FCG-75*

N/A

74

81

N/A

75,100

16

61

57

26-1/2

14-3/4

16

50-1/4

4

FCG-100*

N/A

98

81

N/A

75,100

10

68-1/2

65

27-3/4 15-3/16

16

57-3/8

4

172

195

215

275

350

100

100

100

300

300

Отзывы: