background image

 

 

 

 

 

 

 

www.hotwater.com

For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

®

Recovery capacities based on actual performance tests.
* Dual-channel system has 3˝ vent pipe inside 6˝ air intake pipe, for the 40 & 50 gallon models.

The 75-gallon model uses a 4”x 7” co-axial pipe.

All models have 2” foam cavity.
Water connection 3/4” male all models.
All models are certified for sale in Canada (add SMR “T25”).
75 gallon water connections are 12” on center.

E

F

B

A

D

FRONT

MAX VENT

80 

C

EXTERIOR

WALL

6   DIA.

MIN VENT

17 

SIDE

TAPS

H

G

42°

47°

25-1/4

69°

55°

TOP

INL

ET

DRAIN

T&P

OUTLET

Important! Vent Installation and Termination Requirements

Maximum horizontal vent distance is 80” to outside of exterior wall.

Minimum horizontal vent distance is 17” to outside of exterior wall.

Vent pipes may be trimmed (cut) for short vent installations.

For vent installation less than 30” the vent restrictor is required. Place restrictor

over the flue outlet on heater before installing the outlet vent pipe to the heater.

Recommended installation height for the heater vent pipe should be 68” for 40

gallon models and 76” for the 50-gallon and 75-gallon models (vent height). 

Offset Vent Arrangement

1. When replacing an existing direct vent model, the new vent pipe 

may drop from the minimum vent height as much as 7 1/4” to exit 
through the existing vent opening in the exterior wall.

2. Vent may have one horizontal 90 degree turn before exiting through 

exterior wall (Do not combine both offset vent arrangements in one 
installation) (See examples in the installation manual)

High Rise Vent Arrangement

3. When vent termination is more than 80” above 

the base of the heater. The horizontal vent run must 
be a minimum of 22” from the center of the heater to 
the outside exterior wall surface. (See example in the 
installation manual)

Vent termination clearance hole through the exterior 

wall should be approximately 7” diameter.

Snow accumulation and drifting should be considered 

when locating the termination.

An optional wire grill vent cap protector is available 

through the parts department, part number 9006627.

See the installation manual for complete 

installation and venting requirements.

Residential Gas Water Heaters

AOSRG46400

Revised

 2009

Page 2 of 2

SL

DIRECT-VENT

40 & 50 gal.

25-1/4

75 gal.

29-1/2

MODEL

NUMBER

FIRST

HOUR

RATING

GALLONS

ENERGY

FACTOR

GAL.

CAP.

BTU

INPUT

PER

HOUR

RECOVERY

90ºF RISE

GALLONS

PER HOUR

A

B

C

D

E

F          

VENT

OUT-

LET*

APPROX.

SHIPPING

WEIGHT

(LBS)

GDV-40L

73

.62

40

38,000

41

68 54-3/4 22-1/4

16

12-1/4 45-1/4

Co-Axial

167

GDVT-50L

88

.58

50

50,000

55

76 64-3/4 22-1/4 16-1/4 12-1/2 55-1/2

Co-Axial

187

GDV-75L

131

.57

75

55,000

60

76 65-3/4 26-1/4 16-1/4 12-1/2 55-1/2

17-1/4

54

Co-Axial

310

DIMENSIONS IN INCHES

41-3/4

53-3/4

16-1/2

16-1/2

G

H

6” DIA. on 40 & 50 Gallon Models

7” DIA. on 75 Gallon Models

75 gal vent 
termination 
cap is not 
interchangeable
with vent cap 
on 40 & 50 gal
models

 September

April 2011R

Отзывы: