background image

Residential Gas Water Heaters

*Location for optional top-mounted 
  T&P Valve if ordered from factory.

A. O. Smith FVIR design meets the American  National Standards Institute standards

 

 

 

(ANSI Z21.10.1 - CSA 4.1) that deal with the accidental or unintended ignition of

 

 

 

 

 

 

 

 

  

flammable vapors, such as those emitted by gasoline. 

Feature a sealed combustion chamber with air intake filter and a flame arrestor built
into the water heater base. In addition, a thermal cutoff (TCO) device, is designed
to shut off gas flow to the burner and pilot if poor combustion is detected.

Flammable Vapor Ignition
Resistant (FVIR) Water Heaters

   

AOSRG45551

Recovery capacity based on actual performance tests.

Water Connections – 3/4" on all models.
† Propane Gas – 37,000 BTU input for 50 gallon models & 36,000 BTU for 40 gallon models and 32,000 BTU input for 30 gallon models.
For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XCV-40). 

Heat Trap Nipples factory-installed on all models.

www.hotwater.com

For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make produ ct changes or improvements without prior notice.

Maximum Hydrostatic Working Pressure: 150 PSI.

Page 2 of 2

SERIES 300/301

If flammable vapors accidentally enter the 
combustion chamber, the arrestor is designed 
so flames burn off the top surface and can not 
escape down through the arrestor.

A. Industry standard thermopile
B. Large View Port for easy burner inspection
C. 360

0

 combustion air filter

D. Thermal Cutoff (TCO) with manual reset

MODE L

NUMBE R

FIRST

HOUR

RATING

GALLON S

ENERG Y

FACTOR

GALLO N

CAPACIT Y

BTU

INP UT

PER  HOUR

NATURA L

RECOVERY

90ºF  RIS E

GALLON S

PER  HOUR

FOAM

THICKNES S

(INCHES)

A

B

C

D

E

F

DRAF T

HOOD

OUTLE T

APPR OXIM ATE

SHIPPIN G

WEIGHT

(LBS )

TALL MODEL S

GCV-30

67

.61

30

35,500

36

1

61-1/2    58

16

13

8

    52

3 or 4

112

GCV-40

70

.59

40

40,000

41

1

61-3/4 58-1/4

18

13

8

51-3/4

3 or 4

138

SHORT MODE LS

DIMENSION S IN INCHE S

GCV-50

88

.58

50

40,000

41

1

60-3/4

57

20

13

8

50-1/4

3 or 4

153

60

GCVL-30

.61

30

35,500

36

1

50

46-3 /8

18

  

    8

40

3 or 4

112

®

13-1/2

66

B

A

F

D

1/2" GAS
CONNECTION

VALVE

C

COLD
CONNECTION

E

HOT
CONNECTION

ANODE ROD*

234324_AOSRG45551.indd   2

234324_AOSRG45551.indd   2

4/6/11   8:19 AM

4/6/11   8:19 AM

Отзывы: