background image

 
 
 
 
 

INSTRUCTION MANUAL  

MODELS: 

 

MEV 50 EC, MEV 80 EC, MEV 100 EC, MEH 50 EC, MEH 80 EC, MEH 100 EC

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS  

 

Installation of the water heater shall be done by a qualified technician. 

 

 

It is recommended to install the water heater as near as possible to the hot water faucets. 

 

 

Place the water heater in such a manner that it is accessible for maintenance and cannot cause damage in case of leaking. 

 

 

Before connecting the water heater to the water supply pipes, let the water flow for a few minutes to clean the water supply  from 
any foreign material that may have entered the water pipes. 

 

 

Water supply pressure should be less than 8 bar. If water pressure is higher, install a suitable pressure regulator. 

 

 

Connect the safety valve/check valve to the inlet pipe (blue). Connect the cold water supply to the safety valve. 

 

 

The safety valve can drip during the heating cycle of the water heater to relieve excess water due to heat expansion. Provisions for 
draining the relieve water should be made by using a funnel to collect dripping water, so drain is always open to the atmosphere 
and cannot ever be blocked. Make sure the drain pipe is in continuously downward direction and in a frost free ambient. 

 

 

Connect the hot water pipe to the hot water outlet (red).

 

 

 

Connection  to  the  power  supply  shall  be  via  a  three  core  cable  at  least  1.5  mm

2

.  One  of  the  cores  is  for  earth  connection  (see 

ELECTRICAL CONNECTION diagram). 

 

 

Open  the  cold  water  supply  line.  The  water  heater  is  completely  filled  with  water  when  water  flows  uninterrupted  from  the  hot  
water faucets. 

 

 

When the water heater is completely filled, close the hot water faucets and switch on electricity supply. 

 

 

MAINTENANCE AND CLEANING  

Check  proper  functioning  of  the  safety  valve  every  two  months  by  opening  and  closing  the  test  lever.  The  heating  element  should  be 

checked annually for scale formation, caused by impurities in the water supply. Also the anode should be checked annually and replaced 
when worn for more than 60%. For cleaning the element or replacing the anode follow following procedure: 

 

1.

 

Switch off the electric supply to the water heater 

 

2.

 

Open the hot water taps until water is not hot any more 

 

3.

 

Close cold water supply 

 

4.

 

Put a vessel of suitable capacity under the water heater 

 

5.

 

Drain the water heater by removing the bottom cover, unscrew the heating assembly flange and allow the water to fall in the 
vessel 

 

6.

 

Clean the container and the heating unit assembly from scale by using a suitable acid or by gently scraping of the scale. 

 

7.

 

Replace anode if required 

 

8.

 

Remount the heating assembly flange 

 

9.

 

Open cold water supply until water flows without interruption from hot water faucets 10.

 

Close the hot water taps and check 

for eventual leakage around the flange 11.

 

When there is no leakage, replace cover. Then switch on electric supply. 

 

12.

 

The pressure relief device is to be operated regularly to remove lime deposits to verify that it is not blocked.

 

 

 

 
Warranty 

 

1.

 

If  within  one  year  after  initial  installation  date  any  part  or  component  other  than  the  tank  shall  prove  defective  in  material  or 
workmanship upon examination by A.O. Smith or local authorized agent, A.O. Smith will repair or supply such part or component 
through the local agent. 

 

2.

 

It within five years after initial installation the tank fails due to rust or corrosion from the water side, A.O. Smith will  supply a new 
water heater of  equivalent size and  capacity. Delivery  and installation  charges are not included in this  warranty. The replacement 
water heater will be granted warranty for the unexpired part of the warranty of the originally installed water heater.   

 

3.

 

The warranty only applies if: 

 

a.     The water heater has been installed as per the above instructions 

 

b.     Maintenance has been carried out as per above instructions 

 

c.     Safety valves and anodes have been kept in working condition 

 

4.

    

The warranty is void if: 

 

a.

 

The tank has been damaged by external causes 

 

b.

 

In case of misuse, neglect or incorrect use of the water heater 

 

c.

 

In case of use with non potable water or water softened to less than 60 ppm CACo3 

 

d.

 

In case of unauthorized alteration, modification or repair. 

 

 
 
 
 