background image

 

10 
 

Table of Contents

 

 

Important Notes 

……………………………………………………………………  11 

Product Characteristic

 

……………………………………………………………………  12 

Filters Installation 

……………………………………………………………………  12 

Product Features 

……………………………………………………………………  13 

Product Specifications 

……………………………………………………………………  13 

Packing List

 

……………………………………………………………………  13 

Operation Instructions    ……………………………………………………………………  14 

Maintenance  

……………………………………………………………………  16 

Troubleshoot 

……………………………………………………………………  18 

Warranty 

……………………………………………………………………  19 

 

 

 

 

Содержание KJ800F-B01-HK

Страница 1: ...Instruction Manual 使用說明書 Air Purifier 空氣淨化器 Model 型號 KJ800F B01 HK Please read this manual before use 使用前請細閱本說明書 ...

Страница 2: ......

Страница 3: ...of Contents Important Notes 11 Product Characteristic 12 Filters Installation 12 Product Features 13 Product Specifications 13 Packing List 13 Operation Instructions 14 Maintenance 16 Troubleshoot 18 Warranty 19 ...

Страница 4: ...he machine near heat source otherwise the casing of the machine may be deformed 12 Do not insert finger or object into the air inlet or outlet otherwise it may cause body injury or damage to the machine 13 Do not operate the machine while spraying insecticides The substance of insecticides can be accumulated in the machine If the machine operates again the substance will volatilize to the air and ...

Страница 5: ... inhibit bacteria to grow for healthiness Filters Installation 1 Pre filters installation 2 Main filters installation 1 Disconnect the power supply open the inlet louver on both sides 2 The handle on the filter should toward inlet louver and replace both pre filters together as shown above 3 Close both inlet louvers after replacement of pre filters 1 Open the top cover by pressing the lock on both...

Страница 6: ...6 x 768 Packing List Each unit of air purifier should pack with the following items No Item Unit QTY Note 1 Air Purifier No 1 2 Instruction Manual No 1 3 Pre filters PC 4 2 pieces have been pre installed by factory 4 Main filters PC 2 Have been placed inside the unit remove packing before operation 5 PM2 5 Sensor Filters PC 2 Have been placed inside the packaging of instruction manual Top Cover Co...

Страница 7: ...ent for sleeping Quick Suggest to select this mode if environment is badly polluted Keep pressing the wind speed selector to adjust wind speed Note The sensors will initialize after the first time of the unit is being connected to the power supply or being turned on again after the units is not in used for a period of time The process of initialization will take 2 5 minutes to complete After this ...

Страница 8: ...ad Air Cleanliness Halo The PM2 5 and Gas Monitors also equipped with Air Cleanliness Halos the Halos will change in color to illustrate 4 different grading of air cleanliness as below Excel Blue Good Yellow Mod Orange Bad Red Note The gas sensor is not designed to detect a specific type of gas pollutant When user measures a specific type of gas pollutant such as formaldehyde the result of measure...

Страница 9: ...rtment Please replace this filter together with the pre filters Two spare filters have been placed inside the packaging of the instruction manual 1 Clean the louver of the sensor with a cotton swab 2 Remove the cover of sensor 3 Clean the air inlet outlet and surrounding area of sensor with a cotton swab 1 Open the top cover and pull down the PM2 5 sensor cover as shown above 2 Replace a new prote...

Страница 10: ...s together with alarm to alert user to replace filters immediately If no action has been taken the performance of purification will be affected and the unit will be shut down by electronic system eventually to prevent secondary pollution III To reset filters lifespan indicators Step One Replace Main Pre filters Replace main pre filters according to instruction and indication of unit Step Two Reset...

Страница 11: ... environment such as smoking room or barbeque restaurant In this circumstance filters needed to be replaced and reset indicators frequently even not prompted by indicators Is there any dust or filth has been accumulated in the air in outlet Clean air in outlet louvers sensors and filters regularly The air flow rate doesn t react to the change of displayed measurement Is Sleep or Quick Mode selecte...

Страница 12: ...odel or like kind specifications and quality at A O Smith Hong Kong sole discretion A O Smith Hong Kong will not make any form of compensation refund or offer for the price difference of any product or spare part 6 A O Smith Hong Kong reserve the rights to choose to provide on site or workshop repairing service And A O Smith Hong Kong will not provide air purifier borrowing service 7 After the one...

Страница 13: ...此頁特意留空 This page is intentionally left blank ...

Страница 14: ...此頁特意留空 This page is intentionally left blank ...

Страница 15: ......

Страница 16: ......

Отзывы: