www.hotwater.com
11
WATER PIPING - MIXING VALVE USAGE
Mixing Valves
Water temperature over
125°F (52°C) can cause
severe burns instantly
resulting in severe injury or
death.
Children, the elderly and the
disabled and are at highest
risk of scald injury.
Feel water before bathing or
showering.
Temperature limiting devices
such as mixing must be
installed when required by
codes and to ensure safe
temperatures at fixtures.
BURN
HOT
HOT
DANGER
Water heated to a temperature which satis
fi
es space
heating, clothes washing, dish washing, and other
sanitizing needs can scald and cause permanent injury
upon contact. Short repeated heating cycles caused by
small hot-water uses can cause a temperature increase
of the hot water by 20F° (11C°) higher than the heater’s
temperature settings.
MIXING VALVE
SHUT-OFF
VALVE
SUGGESTED PlPING
ARRANGEMENT FOR
TOP CONNECTIONS
COLD-WATER
INLET
TEMPERED
POTABLE WATER
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
GAS
SUPPLY
TEMERATURE-
PRESSURE
RELIEF VALVE
DRAIN
VALVE
METAL DRAlN
PAN 1.75”
(45mm) MAX.
DEPTH.
AT LEAST
2” (50mm)
GREATER THAN
THE DIAMETER
OF THE WATER
HEATER.
6” (150mm)
MAX. AIR
GAP*
TO SUITABLE
DRAIN
CERTAIN
MODELS ARE
EQUIPPED WITH
SIDE PLUMBING
CONNECTIONS
FOR SPACE
HEATING. THE HOT
AND COLD FITTING
ASSEMBLlES
(PART #9001262)
CAN BE ORDERED
THROUGH THE
MANUFACTURER
* NOTE: THE
T&P VALVE
CAN BE PIPED
DIRECTLY TO
THE DRAIN
MASSACHUSSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.
Figure 8
This appliance has been design certi
fi
ed as complying
with American National Standard/CSA Standard for water
heaters and certain models with side plumbing connections
are considered suitable for Water (Potable) Heating and
Space Heating.
Note:
Do not use in space heating only
applications.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal
hot and cold water pressures.
MIXING VALVE
SHUT-OFF
VALVE
SUGGESTED PlPING
ARRANGEMENT FOR
TOP CONNECTIONS
COLD-WATER
INLET
TEMPERED
POTABLE WATER
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
GAS
SUPPLY
TEMERATURE-
PRESSURE
RELIEF VALVE
DRAIN
VALVE
METAL DRAlN
PAN 1.75”
(45mm) MAX.
DEPTH.
AT LEAST
2” (50mm)
GREATER THAN
THE DIAMETER
OF THE WATER
HEATER.
6” (150mm)
MAX. AIR
GAP*
TO SUITABLE
DRAIN
* NOTE: THE
T&P VALVE
CAN BE PIPED
DIRECTLY TO
THE DRAIN
MASSACHUSSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.
NON-TEMPERED
WATER SUPPLY
NON-TEMPERED
WATER RETURN
Figure 9
ALTERNATIVE PlPING
ARRANGEMENT
COLD-WATER
INLET
TEMPERED
POTABLE WATER
DISCHARGE
PIPE (DO NOT
CAP OR PLUG)
MIXING
VALVE (SET
TO 120°F
(49°C))
NON-TEMPERED
WATER SUPPLY
TEMERATURE-
PRESSURE
RELIEF VALVE
FOLLOW THE
MIXING VALVE
MANUFACTURER’S
INSTRUCTIONS
MASSACHUSSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.
Figure 10
Содержание GPVL Series