TROUBLESHOOTING

For your safety, water heater service should be performed only by a qualified service technician.

Read the GENERAL SAFETY INFORMATION section first.

  WARNING: DO NOT BY-PASS ANY CONTROLS TO MAKE HEATER OPERATE. OPERATE ONLY AS WIRED FROM FACTORY.

1) Blower will not run

A ) “ON/OFF” control switch turned off
B) Blower unplugged
C) No power at outlet
D) “ON/OFF” switch defective
E)

Control harness defective

F)

Blower motor defective

2) Blower running, burner not on

A ) Fan not running fast enough to close

air switch contacts

B) Air pressure switch defective
C) Gas valve defective
D) Control harness defective
E)

Igniter defective

F)

Unit has completed three trials to light
and failed

G) Discharge air limit tripped

3) Thermostat problems

A ) Thermostat set too low
B) Thermostat or ECO defective
C) High limit control circuit open

4) Others

A ) Heater undersized
B) Low gas pressure
C) Incoming water is unusually cold
D) Leaking hot water pipes or fixtures
E)

Polarity reversed

F)

Heater not grounded

A ) Blower does not run when heater fired

B) Not enough dilution air to mix with flue

 gases

C) Air in room too hot for mixing with flue gases

D) Wrong burner orifice
A ) Dirt in burner ports
B) Combustion air path restricted

C) Not enough room air for proper combustion

A ) Water on the floor under heater

Improperly sealed, hot or cold supply connections,
relief valve, drain valve or thermostat threads
Leakage from other appliances or water lines
Condensation of flue products
Thermal expansion in closed water system
Improperly seated valve
High sulfate or mineral content in water supply or
iron or sulfate reducing bacteria in water supply
Outlet polarity is reversed

PROBLEM

POSSIBLE MALFUNCTION

        SERVICE TO BE PERFORMED

NOT ENOUGH OR

NO HOT WATER

VENT PIPE TOO HOT

(ABOVE 170° F)

YELLOW FLAME

CONDENSATION

WATER LEAKS

LEAKING T&P VALVE

HOT  WATER  ODORS  OR  COLOR

(Refer to CATHODIC PROTECTION)

HEATER LIGHT GOES OUT

IN 4-5 SECONDS

Turn switch to the “ON” position.
Plug blower back into 115 vac. outlet.
Repair service to outlet.
Replace switch.
Replace control harness.
Replace blower and motor.
Replace switch.
Check for low voltage, less than 102 vac., have service
checked and repaired.
If voltage is above 102 vac., make sure there is not more than
30 Equivalent feet of 3 inch pipe or85 equivalent feet of 4 inch
pipe installed or vent terminal blockage.
If at least 102 vac., less than 30 equivalent feet of 3 inch pipe
or 85 equivalent feet of 4 inch pipe and not terminal blockage,
replace blower.
Replace switch.
Replace gas valve.
Replace harness.
Replace igniter.
Reset cycle by turning switch off and then back on. If unit
does not light in three trials, call an authorized service
representative.
Verify dilution air openings are free of obstructions.
Make sure there is no more than 30 equivalent feet of 3 inch pipe or
85 equivalent feet of 4 inch pipe.
Check for low voltage, less than 102 vac., have service
checked and repaired.
Make sure vent terminal is not blocked.

Turn temperature control higher.
Replace thermostat.
Replace.

Reduce hot water use.
Contact an authorized service representative.
Allow more time for heater to re-heat.
Have plumber check and repair leaks.
Correct wiring
Correct
Take unit out of service immediately, call an authorized service
representative.
Proper air circulation must be provided for combustion and
dilution of flue temp. Refer to “INSTALLATION” section.
Room air to be used for dilution with combustion products in
flue should be less than 90°F.
Install correct orifice.
Turn off heater and gas, clean burner head.
Clear area around heater and check under heater, remove
any debris under heater and in openings in bottom cover.
Refer to installation manual - Confined and Unconfined Space
statements on page 4 and 5 for required openings.
See “CONDENSATION.”

Turn off heater & water, repair unit.

Inspect other appliances near water heater.
Refer to “CONDENSATION.”
Install thermal expansion tank (DO NOT plug T&P valve).
Check relief valve for proper operation (DO NOT plug T&P valve).
Drain and flush heater thoroughly, chlorinate, refill and flush
again then chlorinate water supply.
Test polarity and correct.

Содержание GPS-75

Страница 1: ...as well as the WARNINGS and CAUTIONS CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLINGAND USING THISAPPLIANCE GAS WATER HEA...

Страница 2: ...manufacturer by calling 1 800 821 2017 When ordering parts provide complete model and serial numbers see rating plate quantity and name of part desired as listed in fig 1 Standard hardware items may b...

Страница 3: ...to find the cause yourself Go to a neighbor s house leaving your doors open to ventilate the house then call your gas supplier or service agent Keep area clear until a service call has been made At ti...

Страница 4: ...e clearance for servicing this appliance should be considered before installation such as changing the anodes etc Minimum clearances for proper operation are given above WARNING In cold climates provi...

Страница 5: ...micals such as those used for boiler treatment shall NEVER be introduced into this system 3 This unit may NEVER be connected to any existing heating system or component s previously used with a non po...

Страница 6: ...ns in this manual or on water heater With main burner in operation paint pipe joints including flanges and control inlet and outlet with rich soap and water solution Bubbles indicate gas leak To stop...

Страница 7: ...ower vented appliances are classified by building codes as vent connectors Required clearances from combustible materials must be provided in accordance with information in this manual under LOCATION...

Страница 8: ...to the built in drain port of the rubber boot on the blower assembly For your convenience the rubber boot is supplied with a removable cap on the built in drain port Prior to operating the water heat...

Страница 9: ...enclosure E Splice field wiring into existing wiring using code authorized method wire nuts etc F Be certain that neutral and line connections are not reversed when making these connections G Ground h...

Страница 10: ...be supported every 5 feet of vertical run and every 3 feet of horizontal run All piping and fittings must be joined by the proper procedures as described under VENT PIPE PREPARATION FIGURE9 IMPORTANT...

Страница 11: ...type of cutter is used the flare on the end must be completely removed STEP A NOTE Power saws should be specifically designed to cut plastic pipe B Deburring Use a knife plastic pipe deburring tool or...

Страница 12: ...ld not be disturbed immediately after the cementing procedure and sufficient time should be allowed for proper curing of the joint Exact drying time is difficult to predict because it depends on varia...

Страница 13: ...LER and HOTTER buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the blower control box to the OFF position 3 Tur...

Страница 14: ...temperature settings to reduce scald hazards Valves for reducing the point of use temperature by mixing cold and hot water are available See figure 2 Also available are inexpensive devices that attac...

Страница 15: ...t if necessary to keep burner in operation C CHECKINGTHE DRAFT Operate the water heater for several minutes and check to see if it is venting properly by passing a lit match or paper near the opening...

Страница 16: ...d above If you are having a problem with your water heater before calling for service please refer to the following TROUBLESHOOTING sections If service becomes necessary contact your dealer installer...

Страница 17: ...lower back into 115 vac outlet Repair service to outlet Replace switch Replace control harness Replace blower and motor Replace switch Check for low voltage less than 102 vac have service checked and...

Страница 18: ...water heater off for 10 seconds and then back on 2 Replace gas control valve Problem with the internal circuit 1 Turn power to the water heater off for 10 seconds and then back on 2 Replace gas contr...

Страница 19: ...NDLABORRESPONSIBILITY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLYAREPLACEMENTWATERHEATERORPARTTHEREOF THEOWNER IS RESPONSIBLE FOR ALLOTHER COSTS Such costs may include but are not limi...

Страница 20: ...20 A O SMITH WATER PRODUCTS CO INC 500 Tennessee Waltz Parkway Ashland City TN 37015 Phone 1 800 821 2017 Website www hotwater com...

Отзывы: