THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY.  If
the glass lined tank in this water heater shall prove upon examination by A. O.
Smith Corporation (the warrantor) to have leaked during the warranty period
in normal residential use, due to natural corrosion from potable water therein,
the warrantor will furnish the ORIGINAL OWNER a replacement A. O. Smith
water heater of equivalent size and current model, or a replacement thermostat
or thermocouple which fails in normal use, in accordance with the warranty
terms and conditions specified below.  THE A. O. SMITH REPLACEMENT
MODEL OR PART WILL BE WARRANTED FOR ONLY THE UNEXPIRED
PORTION OF THE ORIGINAL WARRANTY.  The warranty period will be
determined by the original installation date of the water heater.  PROOF-OF-
PURCHASE AND PROOF-OF-INSTALLATION ARE NECESSARY TO
VALIDATE THIS WARRANTY.  This warranty is not transferable and applies to
models listed in Table 1.

TABLE 1

WARRANTY PERIOD

MODEL

TANK 

1

PARTS 

2

FPD

6 YEARS

2 YEARS

When the water heater has been used for other than single family residential
application:  1. The tank warranty shall be reduced to 3 years for 10 year
models, and 1 year for 6 year models.  2.  The parts warranty shall be reduced
to one year for all models. Returned parts which meet any of the following
conditions are not covered by this warranty: 1) Improper installation or removal,
2) damaged by other than normal wear, 3) replaced for cosmetic purposes, or
4) returned with defaced date codes.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed and operated
in accordance with 1) all local fire codes and plumbing codes, ordinances and
regulations, 2) the printed instructions provided with it, 3) good industry
practices, and 4) proper safety practices such as but not limited to a properly
sized drain pan if installed in an area where leakage from connections of the
tank would result in damage to the area adjacent to the heater.  In addition, a
new temperature and pressure relief valve, certified by the American Gas
Association must have been properly installed and piped to the nearest drain.

This warranty shall apply only when the heater is:

owned by the original purchaser;

used at temperatures not exceeding the maximum calibrated setting of
its thermostat;

not subjected to excessive water pressure fluctuations and not subject
to an operating pressure greater than 150 P.S.I.;

filled with potable water, free to circulate at all times and with the tank
free of damaging water sediment or scale deposits;

used in a non-corrosive and non-contaminated atmosphere;

used with factory approved anode(s) installed;

in its original installation location;

in the United States, its territories or possessions, and Canada;

sized in accordance with proper sizing techniques for residential water
heaters;

bearing a rating plate which has not been altered, defaced or removed
except as required by the warrantor;

not used in a closed system without a properly sized and installed

thermal expansion tank;

fired at the factory rated input using the fuel stated on the face of the
rating plate;

operated with the inner and outer combustion chamber doors in place;

maintained in accordance with the instructions printed in the manual
included with the heater.

Any accident to the water heater or any part thereof (including freezing, fire,
floods, or lightning), any misuse, abuse or alteration of it, any operation of it in
a modified form, or any attempt to repair tank leaks or parts, will void this
warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR WILL PROVIDE
ONLY A REPLACEMENT WATER HEATER OR PART THEREOF.   THE
OWNER IS RESPONSIBLE FOR ALL OTHER COSTS.  Such costs may
include but are not limited to:

a.

Labor charges for service, removal, or reinstallation of the water heater
or part thereof.

b.

Shipping and delivery charges for forwarding the new water heater or
replacement part from the nearest distributor and returning the claimed
defective heater or part to such distributor except in the state of California
where such charges are the manufacturer’s responsibility.

c.

All cost necessary or incidental for handling and administrative charges,
and for any materials and/or permits required for installation of the
replacement heater or part.

LIMITATION ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability imposed on the
sale of this heater under state law are limited to one year duration for the
heater or any of its parts.  Some states do not allow limitations on how long an
implied warranty lasts, so the above limitations may not apply to you.

CLAIM PROCEDURE

Any claim under this warranty should be initiated with the dealer who sold the
heater, or with any other dealer handling the warrantor’s products.  If this is not
practical, the owner should contact: A. O. Smith Water Products Company,
5621 W. 115th Street, Alsip, Illinois,60803 (800) 323-2636.  Canadian
customers should contact A. O. Smith Enterprises, Ltd., P.O. Box 310-768
Erie Street, Stratford, Ontario N5A 6T3 (519) 271-5800.

The warrantor will only honor replacement with identical or similar water heater
or parts thereof which are manufactured or distributed by the warrantor.

Dealer replacements are made subject to in-warranty validation by warrantor.

PROOF-OF-PURCHASE AND PROOF-OF-INSTALLATION DATES ARE
REQUIRED TO SUPPORT WARRANTY FOR CLAIM FROM ORIGINAL
OWNER.  THIS FORM DOES NOT CONSTITUTE PROOF-OF-PURCHASE
OR PROOF-OF-INSTALLATION.

DISCLAIMERS

NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF
OF THE WARRANTOR WITH  RESPECT TO THE  HEATER  OR THE
INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER
OR PARTS.  THE WARRANTOR SHALL NOT BE RESPONSIBLE FOR WATER
DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR
DAMAGE TO PERSONAL PROPERTY, OR OTHER CONSEQUENTIAL
DAMAGE.  THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS
WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS OR
PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING
IN CONTRACT OR IN TORT.

Some states do not allow the limitation or exclusion of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you.

This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.

IMPORTANT INFORMATION

Model Number___________________________________________

Serial Number____________________________________________

Installation Information_____________________________________

Date Installed____________________________________________

Company’s Name_________________________________________

Street or P.O. Box ________________________________________

City, State, and Zip Code___________________________________

Phone Number __________________________________________

Plumber’s Name_________________________________________

LIMITED RESIDENTIAL GAS WARRANTY

Содержание FPD SEALED SHOT

Страница 1: ... for buying this energy efficient water heater from A O Smith Water Products Company We appreciate your confidence in our products You should thoroughly read this manual before installation and or operation of this water heater Please pay particular attention to the important safety and operating instructions as well as the WARNINGS and CAUTIONS RESIDENTIAL GAS WATER HEATERS OWNER S MANUAL A DIVIS...

Страница 2: ...chased locally A VENT PIPE EXHAUST B ANODE C HOT WATER OUTLET D OUTLET 115 V AC E FLUE BAFFLE F GAS SUPPLY G MAIN MANUAL GAS SHUT OFF VALVE H GROUND JOINT UNION J DIRT LEG K OUTER DOOR L UNION M INLET WATER SHUT OFF VALVE N COLD WATER INLET O INLET DIP TUBE P TEMPERATURE AND PRESSURE RELIEF VALVE Q EMBLEM AND RATING PLATE R INSULATION S VENT TERMINAL EXHAUST T DRAIN VALVE U HSI ASSEMBLY V FLUE W D...

Страница 3: ...ur A O Smith water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary WARNING Should you choose to apply an insulation blanket to this heater you should follow these instructions See Figure 1 for identification of components mentioned below Failure to follow these instruc...

Страница 4: ...OR CONNECTIONS WILL NOT RESULT IN DAMAGE TO THE AREA ADJACENT TO THE HEATER OR TO LOWER FLOORS OF THE STRUCTURE When such locations cannot be avoided a suitable drain pan should be installed under the heater see fig 1 The pan should have a minimum length and width of at least 2 inches greater than the diameter of the heater and should be piped to an adequate drain Drain pans suitable for these hea...

Страница 5: ... valve inlet The valve inlet has a hexagon shape for use with a backup wrench Apply joint compounds pipe dope sparingly and only to the male threads of pipe joints Do not apply compound to the first two threads Use compounds resistant to the action of liquefied petroleum gases Do not use teflon tape on gas valve DISCONNECT THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE FROM THE GAS SUPPLY PIPING ...

Страница 6: ...de The vent shall terminate a minimum 12 above expected snowfall level to prevent blockage of vent termination 5 The vent termination shall not be mounted directly above or within 3 feet horizontally from an oil tank vent or gas meter to avoid potential freeze up from condensation Plan the vent system layout so that proper clearances are maintained from plumbing and wiring Vent pipes serving power...

Страница 7: ...t for a saws all or sabre saw blade Cut around the marked circle staying approximately one quarter inch outside of the line This will allow the vent pipe to easily slide through the opening The resulting gap will be covered up by the vent terminal cover plates Repeat this step on the inside wall if necessary 4 Cut a length of 3 inch PVC pipe about 3 5 inches longer than the wall thickness at the o...

Страница 8: ... vent termination must not be closer than 16 and not farther away than 24 6 The intake vent terminal and the exhaust vent terminal must be oriented facing downward and the same direction The specifications are displayed in figure 7 FIGURE 7 INSTALLATION SEQUENCE NOTE BEFORE BEGINNING INSTALLATION OF ANY VENT PIPE READ VENT PIPE PREPARATION SECTION ON PAGES 12 14 1 After the points of termination h...

Страница 9: ...e the larger flexible rubber coupling on the rear air tube and tighten the hose clamp Make sure to remove plastic cap on air tube before installing coupling 7 Cut a 3 inch PVC pipe approximately 4 inches for the 40 gallon and approximately 5 75 inches for the 50 gallon Take the cut 3 inch PVC pipe and place into rubber coupling and tighten hose clamps Fig 10 8 Locate the blower assembly and previo...

Страница 10: ...be placed so as to hold the harness as close as possible to the side of the unit and away from any hot surfaces THIS UNIT IS MANUFACTURED WITH AN EXTERNAL CONTROL HARNESS FOR EASIER REPLACEMENT IF THE HARNESS OR CONNECTORS SHOULD BECOME INOPERABLE 13 Do not plug in power cord until vent system is completely installed The power vent operates on 110 115 VAC therefore a grounded outlet must be within...

Страница 11: ... ASTM F 891 Schedule 40 CPVC ASTM F 441 or ABS ASTM D 2661 pipe The fittings other than the TERMINATIONS should be equivalent to PVC DWV fittings meeting ASTM D 2665 Use CPVC fittings ASTM F 438 for CPVC pipe and ABS fittings ASTM D 2661 3311 for ABS pipe If CPVC or ABS pipe and fittings are used then the proper cement must be used for all joints including joining the pipe to the Termination Tee P...

Страница 12: ...install the vent system with a slight 1 8 inch per five foot of pipe maximum downward slope maximum of 1 inch in total run 7 The vent system should be installed starting at the blower assembly discharge and running to the coupling installed to join the vent terminal on the inside wall figures 15 16 for reference The vent system should be supported every five 5 feet of vertical run and every three ...

Страница 13: ...ompletely removed NOTE Power saws should be specifically designed to cut plastic pipe STEP A B Deburring Use a knife plastic pipe deburring tool or file to remove burrs from the end of small diameter pipe Be sure to remove all burrs from around the inside as well as the outside of the pipe A slight chamfer bevel of about 10 15 should be added to the end to permit easier insertion of the pipe into ...

Страница 14: ... system to escape 3 Fully open the cold water inlet pipe valve allowing the heater and piping to be filled Fig 1 M 4 Close the hot water faucet as water starts to flow 5 The heater is ready to be operated TEMPERATURE REGULATION DANGER DANGER THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHER AND LAUNDRY ...

Страница 15: ...ny appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Turn the ON OFF switch on the blower control box to the OFF position 3 Set the thermostat to the lowest setting Turn thermostat dial fully...

Страница 16: ...NSI Z223 1 NFPA 54 FAILURE TO REPLACE THE ORIFICE WILL RESULT IN IMPROPER AND INEFFICIENT OPERATION OF THE APPLIANCE PRODUCING CARBON MONOXIDE GAS IN EXCESS OF SAFE LIMITS WHICH COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH WATER HEATING IGNITION SEQUENCE Make sure gas and electric power are connected properly 1 The ignition control module is powered and monitors the system waiting for a call f...

Страница 17: ...t that a serviceman be called to determine the reason for limit operation and thus avoid repeated thermostat replacement Lower the temperature adjustment dial setting on new control VENTING SYSTEM HAVEVENTING SYSTEM CHECKED EVERY SIX MONTHS FOR OBSTRUCTIONS AND OR DETERIORATION IN VENT PIPING POWER VENTER MAINTENANCE The SEALED SHOT venter must be inspected four times a year Points of inspection a...

Страница 18: ...A d e n o i t i s o p t o n r o d e t a n i m a t n o c d o r e s n e s e m a l F y l t c e r r o c y l t c e r r o c d e n o i t i s o p t o n t n e m e l e I S H t o n g n i r i w d o r e s n e s e m a l f r o t n e m e l e I S H y l r e p o r p d e t c e n n o c r e n r u b d n a d o r e m a l f n e e w t e b c a V 0 0 1 n a h t s s e L l o r t n o c o t t u p n i c a V 0 2 1 h t i w n a p r o ...

Страница 19: ... s n I E M A L F W O L L E Y s t r o p r e n r u b n i t r i D A r e n r u b n a e l c s a g d n a r e t a e h f f o n r u T d a e h d e t c i r t s e r h t a p r i a n o i t s u b m o C B r o f t n e m e g n a r r a g n i t n e v e k a t n i k c e h C s n o i t c u r t s b o r e p o r p r o f r i a n o i t u l i d h g u o n e t o N C n o i t s u b m o c r o f t n e m e g n a r r a g n i t n e v e...

Страница 20: ...uding freezing fire floods or lightning any misuse abuse or alteration of it any operation of it in a modified form or any attempt to repair tank leaks or parts will void this warranty SERVICE AND LABOR RESPONSIBILITY UNDER THIS LIMITED WARRANTY THE WARRANTOR WILL PROVIDE ONLY A REPLACEMENT WATER HEATER OR PART THEREOF THE OWNER IS RESPONSIBLE FOR ALL OTHER COSTS Such costs may include but are not...