10
1.3.2 Technical data
Device category: II2H3+
DESCRIPTION
unit
EQ 280
EQ 380
DATA NATURAL GAS G20 - 20 mbar:
Nominal heat input (lower value)
k W
22.6
24.0
Nominal power
k W
19.2
20.4
Inlet-pressure (G20)
mbar
20
20
Burner pressure (G20)
mbar
12.5
8.7
Gas consumption (G20) *
m
3
/h
2.4
2.5
Diameter main orifice (G20)
mm
3.90
4.50
Diameter pilot orifice (G20)
mm
2 X 0,27
2 X 0,27
Warming-up time
∆
T= 45 K
min.
56
61
DATA BUTANE G30 - 30 mbar:
Nominal heat input (lower value)
k W
22.6
24.0
Nominal power
k W
-
-
Inlet-pressure (G30)
mbar
30
30
Burner pressure (G30)
mbar
30
30
Gas consumption (G30) *
kg/h
1.8
1.9
Diameter main orifice (G30)
mm
2.30
2.35
Diameter pilot orifice (G30)
mm
2 x 0.16
2 x 0.16
Warming-up time
∆
T= 45 K
min.
-
-
DATA PROPANE G31 - 37 mbar
Nominal heat input (lower value)
k W
21.1
22.9
Nominal power
k W
-
-
Inlet-pressure (G31)
mbar
37
37
Burner pressure (G31)
mbar
37
37
Gas consumption (G31) *
kg/h
1.6
1.8
Diameter main orifice (G31)
mm
2.25
2.35
Diameter pilot orifice (G31)
mm
2 x 0.16
2 x 0.16
Warming-up time
∆
T= 45 K
min.
-
-
Содержание EQ 280
Страница 1: ...WATERSTORAGEHEATERS UNITED KINGDOM IRELAND MODELS EQ 280 G EQ 380 G INSTALLATION AND USER INSTRUCTION ...
Страница 9: ...9 Drawing 3 Dimensions ...
Страница 26: ...26 ...
Страница 28: ...0308 645 R0 ...