6
1.3.2
Technical Data
Type
Unit
EES 30
EES 40
EES 52
Tankage
lt.
115
155
190
Number of elements
-
2
2
2
Capacity (220 V)
kW
2,5
2,5
2,5
Capacity (240 V)
kW
3,0
3,0
3,0
Heating time up to 60°C *
(220/240 V)
min
159/134
214/180
263/221
Heating time up to 40°C *
(220/240 V)
min
95/87
129/118
158/133
Tap capacity 1st hour 60°C **
(220/240)
lt.
149/157
187/194
219/227
Tap capacity continuous 60°C **
(220/240)
lt/hr.
43/52
43/52
43/52
Tap capacity 1st hour 40°C **
(220/240)
lt.
248/261
311/324
366/379
Tap capacity continuous 40°C **
(220/240)
lt/hr.
72/86
72/86
72/86
Weight
kg
36
43
48
Type
Unit
EES 66
EES 80
EES 120
Tankage
lt.
250
300
450
Number of elements
-
2
2
2
Capacity (220 V)
kW
2,5
2,5
2,5
Capacity (240 V)
kW
3,0
3,0
3,0
Heating time up to 60°C *
(220/240 V)
min
346/291
415/349
632/523
Heating time up to 40°C *
(220/240 V)
min
208/174
249/209
374/314
Tap capacity 1st hour 60°C **
(220/240)
lt.
276/284
323/330
463/471
Tap capacity continuous 60°C **
(220/240)
lt/hr.
43/52
43/52
43/52
Tap capacity 1st hour 40°C **
(220/240)
lt.
459/473
538/551
772/785
Tap capacity continuous 40°C **
(220/240)
lt/hr.
72/86
72/86
72/86
Weight
kg
64
80
125
Содержание EES - 30