background image

 

Page 1 of 4

Revised September 2010

 

AOSTT35100

Commercial Storage Tanks

FACTORY JACKETED AND

INSULATED STORAGE TANKS

These A. O. Smith storage tanks are designed for storing potable water. Fitting locations 
are designed to meet the needs of normal installations plus those for the  
A.  O. Smith Cer-Temp 80

®

 and Shure -Temp

 piping methods.

MODELS

TJ-80S, TJ-80A

TJV-120A, TJV-120M

& TJV-200M

120 Gallon Model

(FOR SELECT MODELS)

®

FEATURES

A. O. Smith storage tanks are ideal for 
use with gas-fired copper heat exchanger 
equipment for storage of any potable water 
at temperatures up to 180°F.

GLASS-LINED TANK - 

Alkaline borosilicate 

composition permanently fused to steel 
by firing at a temperature of 1600°F, 
providing years of corrosion protection and 
dependable use.

HEAVY GAUGE STEEL JACKET -

 With 

baked enamel finish.

THREADED OPENINGS -

 All tanks 

furnished with threaded openings for 
thermometer, relief valve, 2” recirculation 
lines, tankstat, and drain valve.

INSULATION - 

Storage Tanks meet or 

exceed R12.5 minimum thermal insulation 
requirements of the U. S. Department  
of Energy and current edition of  
ASHRAE/IESNA 90.1

TJ-80S, TJ-80A, TJV-120M and TJV-120A

• Fits through 30” door  
• Magnesium anode for anti-corrosion 

protection

TJ-80A

  

• 80 gallons 
• High density foam insulation saves energy, 

helps reduce standby heat loss 

• 160 psi ASME standard working pressure

TJV-120A

  

• 119 gallons 
• High density foam insulation saves energy, 

helps reduce standby heat loss

• 160 psi ASME standard working pressure

TJ-80S 

 

• 80 gallons 
• High density foam insulation saves energy, 

helps reduce standby heat loss  

• 160 psi working pressure

TJV-120M

  

• 119 gallons  
• High density foam insulation saves energy, 

helps reduce standby heat loss

• 160 psi working pressure

OPTIONS

Perfectly balanced manifold kits (120 gallon 
models) allow installation where 240 to 480 
gallons of stored water is required.

TJV-200-M - 175 GALLONS

• 160 psi ASME standard working pressure  
• 2” foam insulation  
• Handhole cleanout (Standard)  
• Fits through 33” door  
• Storage is downsized to 175 gallons for 

a 32” x 77” envelope for space restrictive 
installations.  Model TJV-200 is available 
with 200 gallons of storage.  

• Magnesium anodes for extra  

corrosion protection

5 YEAR WARRANTY

If the tank should leak any time during 
the first 5 years, under the terms of the 
warranty, A. O. Smith will repair or replace 
the tank. Installation, labor, handling 
and local delivery are extra. For complete 
information, consult the written warranty 
or contact A. O. Smith.

AOSTT35100 R August 2010 Storage Tank Spec.indd   1

9/1/10   12:13 PM

Содержание DVE

Страница 1: ...r Magnesium anode for anti corrosion protection TJ 80A 80 gallons High density foam insulation saves energy helps reduce standby heat loss 160 psi ASME standard working pressure TJV 120A 119 gallons High density foam insulation saves energy helps reduce standby heat loss 160 psi ASME standard working pressure TJ 80S 80 gallons High density foam insulation saves energy helps reduce standby heat los...

Страница 2: ...4 32 12 1 4 17 1 4 64 1 NPT ASME PLATE LOCATED UNDER COVER 2 NPT 3 4 NPT 3 4 NPT ANODES 2 NPT TJV 200M 4 1 8 11 42 1 4 62 3 1 2 15 54 1 4 1 NPT FRONT 2 NPT FRONT 2 NPT FRONT CLEANOUT 2 NPT FRONT REAR 3 4 NPT FRONT 2 NPT 3 4 NPT ANODE 29 3 8 TJV 120M 10 3 4 17 3 4 44 1 2 61 3 4 28 9 3 4 21 1 4 50 1 2 2 NPT FRONT 2 NPT FRONT REAR 3 4 NPT 1 NPT ASME PLATE LOCATED UNDER COVER 1 NPT 1 1 4 NPT ANODE 2 N...

Страница 3: ...PT REAR 3 4 NPT FRONT 2 NPT FRONT REAR 3 4 NPT REAR 2 NPT 3 4 NPT ANODE TJ 80S For Technical Information and Automated Fax Service call 800 527 1953 A O Smith Corporation reserves the right to make product changes or improvements without prior notice Commercial Storage Tanks Revised September 2010 Page 3 of 4 www hotwater com AOSTT35100 FLOOR SPACE REQUIREMENTS AOSTT35100 R August 2010 Storage Tan...

Страница 4: ...hown on drawings Interior of tank s shall be glasslined with an alkaline borosilicate composition which has been fused to the steel by firing at a temperature of 1600 F Glass coating shall be continuous over the entire inner surface of the tank Outer jacket shall have a baked enamel finish Meets or exceeds R12 5 minimum thermal insulation requirements of the U S Department of Energy and current ed...

Отзывы: