2

ROUGH-IN DIMENSIONS

RECOVERY CAPACITIES

       Element

U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED

       Wattage

INPUT

36F°

40F°

54F°

60F°

72F°

80F°

90F°

100F° 108F° 120F° 126F°

 (Upper/Lower)

KW

20C°

22.2C°

30C°

33.3C°

40C°

44.4C°

50C°

55.5C° 60C° 66.6C° 70C°

NON-SIMULATANEOUS OPERATION

/1500

GPH

17

15

11

10

8

8

7

6

6

5

5

1.5

LPH

64

58

43

38

32

29

26

23

21

19

18

/2000

GPH

23

20

15

14

11

10

9

8

8

7

6

2.0

LPH

85

77

57

51

43

38

34

31

28

26

24

/2500

GPH

28

25

19

17

14

13

11

10

9

8

8

2.5

LPH

107

96

71

64

53

48

43

38

36

32

30

3000/3000

GPH

34

30

23

20

17

15

14

12

11

10

10

3.0

LPH

128

115

85

77

64

58

51

46

43

38

37

4000/4000

GPH

45

41

30

27

23

20

18

16

15

14

13

4.0

LPH

170

153

114

102

85

77

68

61

57

51

49

4500/4500

GPH

51

46

34

30

25

23

20

18

17

15

14

4.5

LPH

192

173

128

115

96

86

77

69

64

58

55

5000/5000

GPH

56

51

38

34

28

25

23

20

19

17

16

5.0

LPH

213

192

142

128

107

96

85

77

71

64

61

6000/6000

GPH

68

61

45

41

34

30

27

24

23

20

19

6.0

LPH

256

230

170

153

128

115

102

92

85

77

73

SIMULATANEOUS OPERATION

3000/3000

GPH

68

61

45

41

34

30

27

24

23

20

19

6

LPH

256

230

170

153

128

115

102

92

85

77

73

4000/4000

GPH

90

81

60

54

45

41

36

32

30

27

26

8

LPH

341

307

227

205

170

153

136

123

114

102

97

4500/4500

GPH

101

91

68

61

51

46

41

36

34

30

29

9

LPH

384

345

256

230

192

173

153

138

128

115

110

5000/5000

GPH

113

101

75

68

56

51

45

41

38

34

32

10

LPH

426

384

284

256

213

192

170

153

142

128

122

6000/6000

GPH

135

122

90

81

68

61

54

49

45

41

39

12

LPH

511

460

341

307

256

230

205

184

170

153

146

Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation
= 4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single
phase = total watts : voltage.

ROUGH-IN DIMENSIONS

                   Approx.

Models

No.  of           Tank Capacity

                A

              B

               C

            D               Shipping Weight.

Dimensions

Elements

US Gals.

Litres

inches

mm

inches

mm

inches

mm

inches

mm

Lbs.

Kg.

DEL-6

1

6

23

15 1/2

394

14 1/4

362

11

279

-

-

35

15.9

DEL-10

1

10

38

18 1/4

464

18

457

12 1/2

318

-

-

54

24.5

DEL-15

1

15

57

26

660

18

457

20 1/2

521

-

-

58

26.3

DEL-20

1

20

76

22 1/4

565

21 3/4

552

15 3/8

391

-

-

73

33.1

DEL-30

2

30

114

30 7/8

784

21 3/4

552

24 1/8

613

8

203

100

45.4

DEL-40

2

40

151

32 1/4

819

24

610

25  9/16

649

8

203

125

56.7

DEL-50

2

50

189

32  1/4

819

26 1/2

673

25  1/8

638

8

203

166

75.3

DEN-30

2

30

114

34 1/2

876

20 1/2

521

-

-

8

203

98

44.5

DEN-40

2

40

151

45  1/8

1146

20  1/2

521

-

-

8

203

113

51.3

DEN-52

2

50

189

54 7/8

1394

20 1/2

521

-

-

8

203

131

59.4

DEN-66

2

66

250

60 3/4

1543

21 3/4

552

-

-

8

203

176

79.8

DEN-80

2

80

303

59 3/8

1508

24

610

-

-

8

203

211

95.7

DEN-120

2

119

450

62  7/16

1586

29 3/8

746

-

-

8

203

326

147.9

Содержание del and del

Страница 1: ...ement Parts Operation Maintenance Leakage Checkpoints Limited Warranty ADIVISION OFA O SMITH CORPORATION McBee South Carolina USA www hotwater com CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THISAPPLIANCE PLACETHESEINSTRUCTIONSADJACENTTOHEATERANDNOTIFYOWNERTOKEEPFORFUTUREREFERENCE ...

Страница 2: ... 256 230 192 173 153 138 128 115 110 5000 5000 GPH 113 101 75 68 56 51 45 41 38 34 32 10 LPH 426 384 284 256 213 192 170 153 142 128 122 6000 6000 GPH 135 122 90 81 68 61 54 49 45 41 39 12 LPH 511 460 341 307 256 230 205 184 170 153 146 Recovery capacities at 100 F rise equal for non simultaneous element operation 4 1 gal x KW of one element for simultaneous element operation 4 1 gal x 2 3 KW of b...

Страница 3: ...educe the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at a nearby kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow THERE SHOULD BE NO SMOKING OR OPEN FLAME NEAR THE FA...

Страница 4: ...e portions of the wire size tables from the Code are reproduced here The branch circuit should be sized at 125 percent of the heater rating and further increase wire size as necessary to compensate for voltage drop in long runs CALCULATING AMPERAGE OVERCURRENTPROTECTION The heaters come from the factory in two configurations 1 Two wire C 2 circuit for single element heater equipped with a high lim...

Страница 5: ...2 2 12 2 THW T TW THWN XHHW UF USE 12 15 15 10 25 25 8 30 40 6 40 50 4 55 65 3 65 75 2 75 90 1 85 100 FACTORY WIRED FIELD WIRING WHITE FOR 120V For ambient temperatures over 30 C 86 F see Correction Factors Note 13 in Code Portion of Table 310 18 follows Allowable Ampacities of Insulated Aluminum and Copper Clad Aluminum Conductors Not more than three conductors in Raceway or Cable or Direct Buria...

Страница 6: ... DEVICES FOR HOT WATER SUPPLY SYSTEMS ANSI Z21 22 This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into an opening provided and marked for this purpose in the water heater and orient it or provide tubing so INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES INSTALL SUITABLE DRAIN PAN...

Страница 7: ...PPER THERMOSTAT BEHIND JUNCTION BOX DOOR ADJUSTABLE LOWER SINGLE THERMOSTAT Figure 3 shows the approximate time to burn relationship for normal adult skin The thermostats on your water heater have a linear relationship between degrees of angular rotation and the corresponding change in temperature Thus rotating the temperature adjustment indicator 30 angular degrees will result in a 10 degree Fahr...

Страница 8: ...e should be checked to ensure that it is in operating condition Lift the lever on the valve several times until the valve seats properly and operates freely CAUTION THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT It is recommended that the drain valve on this unit be opened once a month and 1 to 2 gallons of water be allowed to drain out This will help to pre...

Страница 9: ...stem A check valve in the inlet system will not permit the expanded hot water volume to equalize pressure with the main A relief valve must release this water or the water heater or plumbing system will be damaged When such a condition is encountered local codes or inspection agency should be consulted to determine which system is acceptable in your area These may consist of Installation of a seco...

Страница 10: ...ctricity and drain tank to perform procedure Water leaks at the elements may be due to 1 Defective element which leaks at terminals or thru flange Replace element 2 Loose element gasket leak a Screw in type tighten with 1 1 2 socket wrench or Part Number 23985 wrench If leak continues remove element discard gasket and clean thread areas Apply nonhardeningPermatex Number 2 to thread areas install n...

Страница 11: ...ny misuse abuse including freezing or alteration of it any operation of it in a modified form or any attempt to repair tank leaks will void this warranty 4 SERVICE and REPAIR EXPENSE Under this limited warranty the warrantor will provide only a replacement water heater or part thereof The owner is responsible for all other costs Such costs may include but are not limited to a Labor charges for ser...

Страница 12: ...ts will be shipped at prevailing prices and you will be billed accordingly The model number of your Water Heater will be found on the rating plated located above the lower access panel Be sure to provide all pertinent facts when you call or visit WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER VOLTAGEAND ELEMENT WATTAGE SERIAL NUMBER PART DESCRIPTION Del 6 10 15 20 Se...

Страница 13: ...9 9003899 9003899 9003899 11 Pipe Nipple 194130 194130 3 194130 3 194130 3 12 Plate Knockout 43293 1 43293 1 43293 1 43293 1 PLUG 13 Cap 42306 1 42306 1 42306 1 42306 1 14 Pipe 9001437 9001437 9001437 9001437 15 16 Thermostat with High Limit Switch 9003945 9003945 9003945 9003945 17 Bracket Thermostat 9003898 9003898 9003898 9003898 18 Valve Relief 9003484 9003741 9003741 9003741 Not Illustrated S...

Страница 14: ...8 181138 181138 15 Junction Box Assembly 195171 195171 195171 195171 16 Manual 195201 002 195201 002 195201 002 195201 002 Not Illustrated Standard Hardware Items May Be Purchased Locally Underlined Parts Are Recommended For Emergency Replacement K W ELEMENT 120V 208V 240V 277V 480V WATTAGE PARTNO PARTNO PARTNO PARTNO PARTNO 1 0 1000W 9002863 90001431 1 5 1500W 9002963 9000145 9002864 9001225 2 0 ...

Страница 15: ... 9003889 9000029 9003892 9003893 9003483 9003487 9003465 9003650 9000734 9000071 9000071 9000071 9000071 9000071 9000308 9000308 9000308 9000308 9000308 SEE ELEMENT WATTAGE CHART ON PAGE 14 9003896 9003896 9003896 9003896 9003896 9003897 9003897 9003897 9003897 9003897 9003898 9003898 9003898 9003898 9003898 9003899 9003899 9003899 9003899 9003899 9003900 9003900 9003900 9003900 9003900 9003903 90...