background image

52  

Page

PARTS LIST

Item #

Description

Part #

140 model

T-H3M model

001

Case assembly for Indoor model

Case assembly for Outdoor model

N/A

N/A

EK450

EK451

002

Front cover for Indoor

Front cover for Outdoor 

N/A

N/A

EK452

EK453

003

004

005

006

007

Intake air port assembly

Bracket

Junction box

Power supply cord assembly

Back guard panel 

320273-350

N/A

319143-510

320273-352

N/A

EK454

EK455

EK190

EK456

EK457

050

051

052

053

Screw M4×12 (W/Washer)

Screw M4×10 (W/Washer)

Screw M4×10 (Coated)

Screw M4x10

319143-025

319143-325

319143-026

319143-060

EW000

EW001

EW002

EW003

054

055

056

057

Hex head screw M4×12 (W/Washer)

Hex head screw M4x8

Pan screw M4X20

Tap tight screw M4x12 FEZN

319143-326

319143-063

N/A

319143-201

EW004

EW005

EW018

EKK31

058

059

060

Screw M3x6 SUS

Screw M4x6

Screw M3x6

319143-087

319143-328

N/A

EW00A

EW009

EK191

061

062

063

064

Pan screw M4x8

Wire clamp 60

Screw M4x10

Screw M3x6 SUS3

319143-059

319143-048

320273-497

319143-330

EW00D

EM167

EW00P

EW00B

101

102

Burner assembly

Manifold with gas valve assembly LP 

Manifold with gas valve assembly NA 

320273-353

320273-354

320273-356

EK458

EK459

EK460

103

Fan motor for Indoor model

Fan motor for Outdoor model

319143-443

319143-043

EK109

EKK25

104

105

106

107

Burner gasket

Fan damper for Indoor model

Fan damper for Outdoor model

Burner window

Rod holder gasket

319143-031

320273-557

319143-282

319143-033

319143-034

EKK2X

EK491

EM381

EKK2V

EKK2W

108

109

110

111

Flame rod

Igniter rod

Rod holder 

Rod cap 

319143-517

320273-357

319143-036

320273-358

EK193

EK461

EKK32

EK462

112

113

114

115

Burner damper Indoor

Burner damper Outdoor

Manifold gasket A

Manifold gasket B

Burner holder gasket

320273-359

320273-360

319143-044

319143-045

319143-032

EK463

EK464

EKK2Y

EKK2K

EKK0G

116

117

118

119

Pressure port

Combustion chamber tube

Gas inlet

Gas inlet ring

319143-042

319143-344

320273-362

319143-049

EKK2D

EX019

EK465

EKK2Z

120

Surge box plate

N/A

EK466

Parts List

Owner's Guide

Содержание ATO-140H-P

Страница 1: ...iately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed b...

Страница 2: ...28 APPLICATIONS 29 INITIAL OPERATION 31 OPTIONAL ITEMS 32 Owner s Guide OPERATING SAFETY 35 NORMAL OPERATION 37 Display of controller 37 General 37 Temperature table of controller 37 Temperature sett...

Страница 3: ...t you read through this safety manual carefully Please refer to the back of the manual for details about the warranty Keep this manual for future reference If you lose the manual contact the manufactu...

Страница 4: ...Indoor T H3M DV 140 Outdoor T H3M OS Natural Gas Input Operating Range BTU h Min 15 000 Max 120 000 Propane Input Operating Range BTU h Min 15 000 Max 120 000 Gas Connection 1 2 NPT Water Connection...

Страница 5: ...stalled outdoors The principle behind tankless water heaters is simple This diagram illustrates tankless water heater design concepts only and does not accurately represent the water heater s physical...

Страница 6: ...does not match your requirements do not install and consult with the manufac turer 5 If any problem should occur turn off all hot water taps and turn off the gas Then call a trained technician or the...

Страница 7: ...of the gas or cause damage to the water heater Regularly ensure that the area around the water heater is dust or debris free Regular maintenance is recommended for these types of environments Sealed c...

Страница 8: ...is required to be installed under the water heater in case of leaks It is recommended to direct vent the heater WARNING Damage caused by water quality is not covered by the warranty Only potable water...

Страница 9: ...5 mm 4 in 102 mm 1 in 25 mm 3 in 76 mm 140 Outdoor T H3M OS 36 in 914 mm 12 in 305 mm 24 in 610 mm 1 in 25 mm 3 in 76 mm 24 inches recommended for maintenance Top Back Side Side Front Bottom Do not in...

Страница 10: ...y also be vented with plastic pipe materials such as ABS PVC CPVC or Polypropylene For details please refer to the Exhaust Vent ABS PVC CPVC or Polypropylene Vent section on p 11 Vent installations in...

Страница 11: ...x vent length For details on the vent connection refer to p 13 to 16 No of Elbow 2 venting 3 venting 4 venting 0 to 3 000 ft 0 to 3 000 ft 3 001 to 6 000 ft 6 001 to 10 100 ft 0 to 10 100 ft 0 6 5 ft...

Страница 12: ...No 6 ON No 7 ON OFF ON 1 2 3 4 5 6 7 8 9 10 OFF ON 1 2 3 4 5 6 7 8 9 10 OFF ON 1 2 3 4 5 6 7 8 9 10 Set DIPswitches shown in the tables below depending on the vent length Only adjust switches with a...

Страница 13: ...ectly on the intake vent collar of the water heater 2 Connect a 3 x 2 reducer directly on the exhaust vent collar of the water heater Make sure the couplings engage the o rings installed in the intake...

Страница 14: ...Intake vent collar Female The water heater came with a metal screen that will fit into a 3 inch elbow For details of the optional items refer to the Installation manual for each optional item 1 Conne...

Страница 15: ...ect vent Single pipe with room air intake Terminations Wall Hanger Hanger Roof Roof flashing Fire stop Termination Wall Hanger Roof flashing Fire stop Roof Refer to pages 17 and 19 for clearance infor...

Страница 16: ...re rating of 160 F For best results a vent system should be as short and straight as possible The Indoor model is a Category IV appliance and must be vented accordingly with any 4 inch vent approved f...

Страница 17: ...ine extended above meter regulator assembly 3 feet I Clearance to service regulator vent outlet 3 feet J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any oth...

Страница 18: ...ion at least 1 ft 305 mm away from each other no matter the orientation A direct vent termination must also be at least 2 ft 610 mm away from an inside corner If the adjacent wall is less than 2 ft 61...

Страница 19: ...ust gas 3 ft 914 mm min B A 2 ft 610 mm min Intake air B B A Exhaust Gas A Exhaust terminations must be at least 1 ft 305 mm away from any obstructions B Intake terminations must be at least 1 ft 305...

Страница 20: ...g system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The water heater must be isolated from the gas supply piping system by closing its individual manual...

Страница 21: ...ple Natural Gas Unit kBTU per hour Pipe Size Length Diameter 10 20 30 40 50 60 70 80 90 100 125 150 200 1 2 268 184 148 126 112 101 93 87 82 77 68 62 53 3 4 567 393 315 267 237 217 196 185 173 162 146...

Страница 22: ...nder water Immediately call a licensed professional to inspect the water heater to replace any damaged parts Do not reverse the hot outlet and cold inlet connections to the water heater This will not...

Страница 23: ...the discharge tube to the pressure relief valve and run the end of the tube to within 6 inches 152 mm from the floor This discharge tube must allow free and complete drainage without any restrictions...

Страница 24: ...tralizer is not required 1 Connect a 1 2 FPT X 3 8 or 1 2 HB Adaptor to the condensate drain port at the bottom of the water heater 2 Connect a condensate drain tube to the 1 2 FPT X 3 8 or 1 2 HB Ada...

Страница 25: ...re replacement However the actual life of the neutralizer may vary depending on the application and usage Please ensure that the cartridge is properly replaced before the neutralizer elements have bee...

Страница 26: ...he Remote Controller 1 Take off the Back plate from the remote controller with a flat head screwdriver Fig A and B 2 Attach the Back plate on the wall with the two provided screws Fig B This remote co...

Страница 27: ...Take off the water heater s front cover 3 Locate the remote controller terminals pictured below located around the lower right hand side of the computer board 4 Take off the back plate from the remot...

Страница 28: ...witches No 3 OFF No 4 OFF No 5 OFF No 3 OFF No 4 ON No 5 OFF No 3 OFF No 4 OFF No 5 ON No 3 OFF No 4 ON No 5 ON No 3 ON No 4 ON No 5 ON OFF ON 1 2 3 4 5 6 7 8 9 10 OFF ON 1 2 3 4 5 6 7 8 9 10 OFF ON 1...

Страница 29: ...ose other uses in order to reduce scald hazard potential Water temperature over 125 F 52 C can cause severe burns instantly or death from scalding Chemicals such as diluted Glycol can be used for radi...

Страница 30: ...des and must meet BTU rating of water heater model used Check valve will have 1 8 inch hole drilling in clapper optional Atmospheric vacuum breaker Shutoff valve Pressure gauge Apply correct thermal e...

Страница 31: ...ng unit for the first time Open the main gas supply valve to the water heater using only your hand to avoid any spark Never use tools If the knob will not turn by hand do not try to force it call a qu...

Страница 32: ...he output temperature from the water heater to be adjusted within the range of 100 F to 140 F and also works as a diagnostic tool and will provide a concise error code whenever there is a problem with...

Страница 33: ...and IV For different wall thicknesses there are two ranges of lengths available Refer to the NovaVent brochure for details Install these vent terminations in accordance with their installation instru...

Страница 34: ...this safety manual carefully Please refer to the back of the manual for details about the warranty Keep this manual for future reference If you lose the manual contact the manufacturer or your local d...

Страница 35: ...Forced or attempted repair may result in a fire or explosion D Do not use this water heater if any part has been under water Immediately call a qualified service technician to inspect the water heate...

Страница 36: ...death serious illness or other reproductive harm This product may contain such substances be their origin from fuel combustion gas oil or components of the product itself Vapors 1 Cannot be seen 2 Vap...

Страница 37: ...F 100 105 110 115 120 125 130 135 140 C 38 40 43 45 50 52 55 57 60 Factory setting Default TEMPERATURE TABLE OF THE CONTROLLER COLD Button HOT Button Pressthe HOT buttonorthe COLD buttontosetthehotwa...

Страница 38: ...ection the DIPswitches should be set to 120 F 50 C DEFAULT 140 F 60 C No 9 OFF No 9 ON OFF ON 1 2 3 4 5 6 7 8 9 10 OFF ON 1 2 3 4 5 6 7 8 9 10 Normal Operation Owner s Guide Operation Screen on the co...

Страница 39: ...troller will not operate temperature settings as only work for the information mode Indoor model only Operation Screen on the controller 1 Press the ON OFF button on the controller in order to turn th...

Страница 40: ...tely drain the water out of the water heater Refer to p 41 2 Disconnect power to your heater This will keep your water heater from freezing and being damaged Only pipes within the water heater are pro...

Страница 41: ...ician If repairs are needed any repairs should be done by a licensed technician UNIT DRAINING AND FILTER CLEANING Turn off the electrical power supply and close the manual gas shutoff valve and the ma...

Страница 42: ...d connect hoses pump to the drain ports of the isolation valves Outlet of the pump to valve B cold side and another hose from valve A hot side to the bucket 4 PUMP and DESCALE a Fill the bucket with 5...

Страница 43: ...re controller is the power button turned on The time it takes to deliver hot water from the water heater to your fixtures depends on the length of piping between the two The longer the distance or the...

Страница 44: ...sounds from the water heater Is the correct gas type of a water heater installed p 6 Are the DIPswitch settings for your altitude set correctly p 28 Check the flame quality p 41 Is the intake or exha...

Страница 45: ...water heater itself or the installation of the unit the error code will be displayed on the temperature controller and remote controller Consult with the table on the following pages for the descript...

Страница 46: ...tion breakage of wires Part 412 707 708 709 710 burn marks on the computer board Part 701 and or soot on the flame rod Part 108 Check if there is a buzzing spark ignition sound coming from the burner...

Страница 47: ...controller Check the model type of the remote controller Inspect the connections between the water heater and remote controller Check the power supply of the water heater 751 N A Miscommunication betw...

Страница 48: ...remote controller Indoor model Outdoor model 702 704 052 052 052 006 704 005 052 004 004 001 007 003 050 002 001 714 002 Temperature controller Indoor model COMPONENTS DIAGRAM Components Diagram Owner...

Страница 49: ...age Computer board assembly Surge box assembly 709 710 103 708 402 707 701 711 716 402 407 408 060 713 706 for Indoormodel for Outdoormodel 701 710 703 120 053 705 712 712 Components Diagram Owner s G...

Страница 50: ...116 053 117 103 105 064 054 104 115 053 053 106 107 108 708 110 061 109 111 709 112 053 114 113 707 102 053 120 709 150 057 055 062 053 711 117 055 119 151 118 051 Manifold assembly Burner assembly C...

Страница 51: ...51 413 451 414 414 451 052 409 457 460 453 408 059 454 410 416 455 458 402 459 457 404 406 456 405 052 453 407 059 416 053 417 A B A B 401 154 E E 467 463 063 455 458 455 467 463 063 455 458 A 455 455...

Страница 52: ...Screw M4x10 Screw M3x6 SUS3 319143 059 319143 048 320273 497 319143 330 EW00D EM167 EW00P EW00B 101 102 Burner assembly Manifold with gas valve assembly LP Manifold with gas valve assembly NA 320273 3...

Страница 53: ...73 365 EK469 415 416 Drain tube Inlet heater 320273 366 319143 468 EK470 EK105 417 Secondary heat exchanger for Indoor model Secondary heat exchanger for Outdoor model 320273 553 320273 554 EK471 EK47...

Страница 54: ...d cover Cable clamp for Indoor model 319143 481 N A 319143 191 319143 500 EK112 EX004 EKK1M EX13C 715 716 Exhaust thermistor for Indoor model Exhaust Hi limit switch wire 319143 131 319143 501 EKH6E E...

Страница 55: ...limited warranty This limited warranty gives you specific legal rights and you may also have other rights which vary from State to State The manufacturer will honor the warranty to the original retai...

Страница 56: ...gas type and or gas pressures that fall outside the product s specified range Water incorrect water pipe sizing water pressures that fall outside the product s specified range recirculation flow rates...

Отзывы: