A.O. Smith APW015DW Скачать руководство пользователя страница 35

35

11  

Sizing data 

(continued)

Indirect Plate Water Heater Installation & Service Manual

  NOTE:

  

Highlighted items are limited by the maximum flow velocity through the piping.

Table 11E

 Sizing Chart _ 40 - 120

8

A

PW070DW

80

3

130

168

14

A

PW120DW

160

2

225

160

15

A

PW105DW

160

2

225

160

15

8

A

PW030DW

80

3

75

130

8

220

A

PW015DW

52

2

75

162

A

PW050DW

80

3

75

A

PW090DW

160

2

160

136

9

130

8

A

PW070DW

80

3

130

158

14

A

PW120DW

160

2

225

150

15

A

PW105DW

160

2

225

151

15

8

AP

W030DW

74

3

75

127

8

210

A

PW015DW

48

2

75

156

A

PW050DW

80

3

75

A

PW090DW

160

2

160

126

9

121

8

A

PW070DW

80

3

130

149

14

A

PW120DW

160

2

225

141

15

A

PW105DW

160

2

225

141

15

8

A

PW030DW

67.5

2

75

125

8

200

A

PW015DW

43.5

2

75

152

A

PW050DW

80

3

75

A

PW090DW

160

2

160

117

9

111

8

A

PW070DW

80

3

130

139

14

A

PW120DW

160

2

225

131

15

A

PW105DW

160

2

225

131

15

8

A

PW030DW

61

2

75

122

8

190

AP

W015DW

39.5

1

75

146

A

PW050DW

79

3

75

A

PW090DW

156

2

160

109

9

105

8

A

PW070DW

80

3

130

129

14

A

PW120DW

160

2

225

121

15

A

PW105DW

160

2

225

121

15

8

A

PW030DW

55

2

75

119

8

180

A

PW015DW

35

1

75

141

A

PW050DW

71.5

3

75

A

PW090DW

140

2

160

107

9

101

8

A

PW070DW

80

3

130

119

14

A

PW120DW

160

2

225

111

15

A

PW105DW

157

2

225

112

15

8

A

PW030DW

48

2

75

117

8

170

A

PW015DW

30.5

1

75

136

A

PW050DW

63.5

2

75

A

PW090DW

124

1

160

105

9

100

8

A

PW070DW

80

3

130

109

14

A

PW120DW

157

2

225

102

15

AP

W105DW

137

1

225

110

15

8

A

PW030DW

41.5

2

75

114

8

160

A

PW015DW

26

1

75

131

A

PW050DW

55

2

75

A

PW090DW

109

1

160

104

9

99

8

AP

W070DW

72

3

130

14

A

PW120DW

134

1

225

101

15

A

PW105DW

115

1

225

108

15

8

A

PW030DW

35

1

75

112

8

150

A

PW015DW

21.5

1

75

126

A

PW050DW

47

2

75

A

PW090DW

92

1

160

103

9

98

8

A

PW070DW

58

2

130

103

14

A

PW120DW

108

1

225

101

15

A

PW105DW

92

1

225

106

15

8

AP

W030DW

27.5

1

75

110

8

140

A

PW015DW

17

1

75

121

A

PW050DW

38

1

75

A

PW090DW

74

1

160

102

9

98

8

A

PW070DW

42

2

130

103

14

A

PW120DW

79

1

225

101

15

A

PW105DW

67

1

225

106

15

8

A

PW030DW

19.5

1

75

109

8

130

A

PW015DW

12

1

75

117

A

PW050DW

27.5

1

75

A

PW090DW

54

1

160

102

9

100

14

A

PW120DW

61

1

225

103

15

A

PW105DW

51

1

225

106

15

8

40‐120

125

A

PW015DW

8.5

1

75

A

PW050DW

21

1

75

A

PW090DW

41.5

1

160

104

9

102

8

A

PW070DW

32.5

1

130

104

DOMESTIC WATER INLET‐

OUTLET (

°

F)

BOILER WATER INLET TEMP 

(

°

F)

A

PW MODEL

DOMESTIC 

BOILER

FLOW (GPM)

PRESSURE LOSS (PSI)

MAX. FLOW (GPM)

OUTLET TEMP (

°

F)

MAX. PRESSURE LOSS (PSI)

115

8

A

PW030DW

15

1

75

109

Содержание APW015DW

Страница 1: ...eries 100 This manual must only be used by a qualified heating installer service technician Read all instructions before installing Perform steps in the order given Failure to comply could result in s...

Страница 2: ...unit 7 3 HYDRONIC PIPING APW piping assemblies 8 General piping information 8 Heating fluid and Domestic Hot Water DHW piping 8 Scalding 8 Hydronic piping illustrations 9 14 4 ADJUSTMENTS 3 Way contro...

Страница 3: ...formation This instruction manual provides detailed coverage for the Indirect Plate Water Heater APW Each APW is equipped with an electronic control system specifically designed for an electronic cont...

Страница 4: ...electronic circuitry for the electronic control system In addition the electronic control system includes several sensors and safety devices which provide temperature and flow control information to...

Страница 5: ...exceed 100 F Do not install the appliance where the relative humidity may exceed 95 Do not install the appliance where condensation may form on the inside or outside of the appliance or where condens...

Страница 6: ...eater Clearances and Dimensions 6 Indirect Plate Water Heater Installation Service Manual MODEL A B C D E APW015DW 55 44 15 35 5 10 5 APW030DW 55 52 15 35 5 10 5 APW050DW 55 52 15 35 5 10 5 APW070DW 6...

Страница 7: ...FIG 2 1 Use these tabs or cutouts to lift and move the unit as specified in the heat exchanger HEX manual supplied with the unit In multiple unit installations it is important to plan the position of...

Страница 8: ...g Assemblies Model Piping Assembly Diameter APW015 APW050 2 APW070 APW090 3 APW105 APW120 4 Indirect Plate Water Heater Installation Service Manual Scalding This water heater can deliver scalding temp...

Страница 9: ...to Water Heat Exchanger Single Unit Please note that these illustrations are meant to show system piping concept only the installer is responsible for all equipment and detailing required by local co...

Страница 10: ...TANK TANK HEIGHT TO DIAMETER RATIO 2 1 MIN 3 1 PREFERRED HOT WATER SUPPLY TEMPERATURE GAUGE Figure 3 3 Water to Water Heat Exchanger Single Unit with Stratified Tank Please note that these illustratio...

Страница 11: ...UPPLY BOILER WATER OUT Figure 3 4 Water to Water Heat Exchanger Multiple Units Please note that these illustrations are meant to show system piping concept only the installer is responsible for all eq...

Страница 12: ...R SUPPLY BOILER WATER IN BOILER WATER OUT BUILDING RETURN Figure 3 5 Water to Water Heat Exchanger Single Unit with Accumulator Tank Please note that these illustrations are meant to show system pipin...

Страница 13: ...Multiple Units with Boiler Side Buffer Tank as a Zone Please note that these illustrations are meant to show system piping concept only the installer is responsible for all equipment and detailing req...

Страница 14: ...ASS LINE Figure 3 7 Multiple Units with Conventional Heating System as a Zone Please note that these illustrations are meant to show system piping concept only the installer is responsible for all equ...

Страница 15: ...control valve Remove hand wheel ring CAUTION As a precaution ensure that all heating fluid hot boiler water shutoff valves are fully closed prior to performing any of the following adjustment procedur...

Страница 16: ...from the temperature controller The valve can now be mechanically rotated The temperature control system is now disabled Be sure to return to the Auto Mode prior to returning the system to heating se...

Страница 17: ...controller These controls and displays are illustrated and described in FIG 4 6 and Table 4B on page 18 If necessary set point temperature adjustment is accomplished as follows 1 Set the ON OFF POWER...

Страница 18: ...al Button and Indicator Not used If MAN is lit in the top of the screen press AUTO MAN to put the control back into Auto Mode Run Hold Button and Indicators Not used for APW applications a Page Button...

Страница 19: ...s position B AB It should be noted that the over temperature switch has a slightly slower response to temperature changes than the temperature controller The control valve actuator also incorporates a...

Страница 20: ...ess into the junction box through one of the knockouts as shown in FIG 6 1 3 Connect 120V power supply to the wires in the junction box Black Live White Neutral Green Ground Use a minimum of 14 AWG wi...

Страница 21: ...onnect wires to the control following the diagram in Figure 7 1 4 Close the control box door 5 Turn on the main electrical power 7 Configure the control per this manual and resume operation Figure 7 1...

Страница 22: ...e outside the expectation of the application program since the MODBUS protocol is unaware of the significance of any particular value of any particular register 04 SLAVE DEVICE FAILURE An unrecoverabl...

Страница 23: ...Maximum Load 32 units 32 nodes NOTE Cable must be terminated with 120 ohm impedance matching resistor on each end Physical Wiring Figure 7 2_Wiring Diagram Mixed Inlet Temperature Domestic Water Outl...

Страница 24: ...n twice to return to Level 1 12 Press Page Should you encounter problems communicating over ModBus the following items should be checked in this order 1 Physical Layer 2 Communications Configuration a...

Страница 25: ...e unit suddenly When unit is hot DO NOT shock with cold fluid WARNING CAUTION Initial start up In order to prevent a possible over temperature condition during initial start up The manufacturer recomm...

Страница 26: ...in Steps 1 and 2 below However if the APW will shut down for an extended period of time it will be necessary to drain the unit using the appropriate steps listed below for the type of heat exchanger u...

Страница 27: ...ners on both the boiler water and domestic water piping side Annually Once each year check the temperature sensors Once each year check the operation of the recirculation pump Periodic Periodic cleani...

Страница 28: ...ection must only be conducted by a plumbing contractor or authorized inspection agency not by the owner Failure to re inspect the water heater relief valve as directed could result in unsafe pressure...

Страница 29: ...ts built in circuit breaker has not tripped Heat exchanger is improperly sized for load Reduce load on heat exchanger or re size heat exchanger Heat exchanger scaled on boiler side Clean and de scale...

Страница 30: ...ce type devices The following tables show the correct values for the sensors at various temperatures Use an ohmmeter to read the resistance of the sensor at a known temperature If the resistance of th...

Страница 31: ...1 160 108 9 105 8 APW070DW 80 3 130 122 14 APW120DW 160 2 225 116 15 APW105DW 160 2 225 116 15 8 APW030DW 59 2 75 121 8 170 APW015DW 38 1 75 138 APW050DW 78 3 75 APW090DW 155 2 160 110 9 105 8 APW070D...

Страница 32: ...W 128 1 160 123 9 117 8 APW070DW 80 3 130 129 14 APW120DW 160 2 225 121 15 APW105DW 142 2 225 128 15 8 APW030DW 43 2 75 132 8 180 APW015DW 27 5 1 75 149 APW050DW 57 5 2 75 APW090DW 112 1 160 122 9 116...

Страница 33: ...5 140 15 8 APW030DW 27 1 75 143 8 180 APW015DW 16 5 1 75 157 APW050DW 36 1 75 APW090DW 71 1 160 134 9 130 8 APW070DW 56 2 130 135 14 APW120DW 104 1 225 132 15 APW105DW 89 1 225 139 15 8 APW030DW 33 1...

Страница 34: ...PW050DW APW070DW APW090DW APW105DW APW120DW 75 75 153 171 8 8 APW105DW APW120DW 19 8 5 1 1 21 1 41 1 APW120DW APW015DW APW030DW APW050DW APW070DW APW090DW APW015DW APW030DW 160 153 9 51 1 225 157 15 7...

Страница 35: ...75 APW090DW 140 2 160 107 9 101 8 APW070DW 80 3 130 119 14 APW120DW 160 2 225 111 15 APW105DW 157 2 225 112 15 8 APW030DW 48 2 75 117 8 170 APW015DW 30 5 1 75 136 APW050DW 63 5 2 75 APW090DW 124 1 160...

Страница 36: ...6 15 APW105DW 140 2 225 125 15 8 APW030DW 43 2 75 130 8 190 APW015DW 27 1 75 152 APW050DW 57 2 75 111 1 160 118 9 111 8 APW070DW 77 3 130 118 14 142 2 225 114 15 APW105DW 122 1 225 124 15 8 APW030DW 3...

Страница 37: ...61 1 225 136 15 8 APW030DW 24 1 75 140 8 180 APW015DW 14 5 1 75 156 APW050DW 33 1 75 APW090DW 65 1 160 129 9 125 8 APW070DW 51 2 130 131 14 APW120DW 95 1 225 127 15 APW105DW 81 1 225 135 15 8 APW030D...

Страница 38: ...169 APW050DW 24 5 1 75 APW090DW 48 1 160 146 9 142 8 APW070DW 38 1 130 147 14 APW120DW 71 1 225 144 15 APW105DW 60 1 225 151 15 APW030DW APW050DW APW070DW APW090DW APW105DW APW120DW 200 210 APW015DW...

Страница 39: ...39 Indirect Plate Water Heater Installation Service Manual 12 Diagrams Figure 12 1 Wiring Diagram Electrical Control System Control Box...

Страница 40: ...Parts Description Kit Model 1 Pump 100346661 APW015DW 070DW 100346658 APW090DW 120DW 2 Control 100346659 APW015DW 120DW 3 Sensor 100346657 APW015DW 120DW 4 T P Valve 100112873 APW015DW 050DW 100346652...

Страница 41: ...41 Indirect Plate Water Heater Installation Service Manual Notes...

Страница 42: ...42 Indirect Plate Water Heater Installation Service Manual Notes...

Страница 43: ...43 Indirect Plate Water Heater Installation Service Manual Notes...

Страница 44: ...on A Process 3000045653_Change 500033372 initial release Revision B Process 3000047064_Change 500034483 made changes to the Replacement Parts List kit numbers for T P Valve and High Limit 100346577_20...