INITIAL SETUP

Proceed to activate the system after checking that the pipe connections are secure and that the system is 

connected to a water source and power supply. 

Ensure the stop valve on the incoming water pipe is ‘on’. Turn on the filter faucet and wait for the first 

flow of water. Allow some time for the water to pass through all filters. If there is no water flowing out of 
the faucet, check if the incoming water pressure is too low.   

When the filter faucet has been running for about 10 minutes, check the body of the filter for any visible 

leaks. Ensure all pipe and wire connections are secure. 

Close off the filter faucet and check to see if the flow of water at the waste water tube stops. The flow 

should stop within 30 seconds. 

INSTRUCTIONS BEFORE USE

Before the water can be consumed, the system requires a thorough flush of the the Reverse Osmosis 

filter. You can do this by letting the filter faucet run for 20 minutes every 2 hours, repeated 7 times. 

Alternatively, let the faucet run for as long as possible on the first day of installation. 

Gas solubility increases as tap water passes through the high-pressure RO filtration process. As a result, 
users may notice tiny bubbles in the pure water, similar to that of bubbles of carbonated drinks. Because 

pure water has no impurities, it takes a long time for the bubbles to dissipate. This is a normal physical 

phenomenon and is harmless to the human body. 

Switch off the filter faucet when not in use.

Used filters cannot be cleaned and recycled. They should be disposed off as solid domestic waste.

If product has not been in use for a long time, reset the system, disconnect and reconnect the water 

source, and perform a thorough flush before you use resume use. 

Should any of the following situations occur, disconnect the water source immediately and power down 

the system: 

- Leak detected at any part of the main body or connecting pipes

- Any part of the system is malfunctioning  

Should any part of the system be damaged, seek professional assistance from an authorised A. O. Smith 

retailer. The manufacturer is not responsible for any loss as a result of failure to operate the system in 

accordance with the instructions in this manual. 

Содержание aosbath MAX4

Страница 1: ...Instruction Manual Domestic RO Water Purifier MAX4 ...

Страница 2: ...ld not be higher than 38ºC 1 IMPORTANT Please read this manual carefully before using the product and store it for future reference If the user installs the water filter by themselves or does it by using the self prepared installation materials AOS Bath will not be liable for any adverse effects on the normal operation and service performance of the system The maintenance of this appliance require...

Страница 3: ... pressure 0 4 0 8 MPa Inlet water temperature 5 38ºC Executive standard Q 320124 AONJ 043 2018 A O Smith integrated reverse osmosis water purifier Raw water source Municipal tap water compliant with GB5749 2006 Water quality compliance Compliant with Sanitary Safety and Functional Evaluation Specification for Drinking Water RO Treatment Equipment 2001 Net weight 15 5 kg Dimensions L x W x H 445 x ...

Страница 4: ...mal Orange The filter life is down to 5 order replacement filters Red The filter life is down to 0 replace filter immediately Indicator light PREPARATION BEFORE INSTALLATION Determine installation location dependent on the actual on site environment Determine various tools required for installation wrench electric drill hole opener screwdriver pipe cutter needle nose plier Cut off water and electr...

Страница 5: ...coming water supply 3 The water pipe and the quick connect joint must be secure to prevent water leakage 1 Installation of metal hose and 3 way valve 1 Fix the water inlet valve at close position and unscrew the metal hose 2 Attach the base end of the three way valve to the inlet valve 3 Attach one end of the metal hose to the top of the three way valve The metal hose connects to the faucet Metal ...

Страница 6: ...rom the base hole 4 When installing the water outlet the base should face the corner of the sink 5 Tighten the two screws 2 Installation of faucet body 1 Cut a water pipe of appropriate length Insert one end into the socket of the main body and the other end through the base beneath the countertop 2 Connect with the water outlet of the water purifier 3 Insert the main faucet body into the base 3 I...

Страница 7: ...ction of the 2 way pipe and the drain pipe with a little silica gel FIXING THE SYSTEM The reverse osmosis water purifier is not to be wall mounted It should be placed directly on the cabinet floor Should the unit need to be fixed on the wall the user must purchase a separate tripod and expansion screws for a secure wall installation POWER CORD CONNECTION Connect the power adapter to the system and...

Страница 8: ...n for as long as possible on the first day of installation Gas solubility increases as tap water passes through the high pressure RO filtration process As a result users may notice tiny bubbles in the pure water similar to that of bubbles of carbonated drinks Because pure water has no impurities it takes a long time for the bubbles to dissipate This is a normal physical phenomenon and is harmless ...

Страница 9: ...articles removed Estimated filter life Model Particle filter Suspended solids rust sand silt organic matter smells prevents crystallization of calcium and magnesium ions in filtration system 12 months MT 4 85mm Carbon filter Removes odors chlorine chloramine and improves taste 12 months CMF 85mm Reverse Osmosis RO membrane filter 0 0001μm precision filtration removes viruses bacteria trace metals ...

Страница 10: ...acing any of the filters switch on the faucet and let the water run from the filter tap for 15 minutes before consuming the water 1 If the filter indicator display does not light up in white adjust the water purifier so that it is at least 2cm away from the sides of the housing cabinet Then remove the filter and reinstall it 2 If the faucet stops dispensing water after any filter replacement switc...

Страница 11: ...ing water supply Inlet valve Waste water Particle filter RO filter Carbon filter Faucet Pressure pump Combination stop valve Backflow valve Main circuit board Stop valve Faucet Pressure pump Inlet valve Combination valve Power supply 220V 36V Left cover Front cover fixed Display panel Pressure pump Water pump cover Right cover Front cover removable Filter Filter handle Top cover Frame Filter circu...

Страница 12: ...relevant filter Filters are not properly installed Reinstall the filters The main circuit board cannot shut off the inlet valve Check the inlet valve and replace if necessary Waste water is released even when faucet is off The inlet valve is malfunctioning Replace the inlet valve No or low flow of purified water Filters are at 0 life Replace the filters Filters are blocked Reinstall the affected f...

Страница 13: ...ssible Is not subject to accidental damage or faults caused by negligence Is not subject to damage from external sources such as transit weather or power surges SERVICE AND LABOUR After the 1st year of warranty the owner is responsible for all other costs Such costs may include but are not limited to labour charges for service removal or reinstallation of the system and delivery handling and admin...

Страница 14: ...hole system after being soaked in pure water for 24 They are in compliance with the Ministry of Health s Drinking Water Quality Processor Hygienic Safety and Functional Evaluation Specification for Anti permeation Treatment Devices 2001 and the requirements in GB5749 2006 HAZARDOUS SUBSTANCES CONTENTS Marked o The content of the hazardous substances in all materials of the part is below the limit ...

Страница 15: ...AOS Bath Service Hotline 68420030 For filter replacements 68420030 AOS Bath Pte Ltd 178 Paya Lebar Road 06 11 Singapore 409030 ww aosbath com ...

Отзывы: