background image

5. SYSTEM DIAGRAM

EXPLODED VIEW DRAWING

Top cover

Steam sensor

Check valve

Heater cover & steam condenser

Right panel

Water level 

sensors

Thermal 

insulation

Bottom cover

Power supply board

LED display

Power button

Solenoid valve

Left panel

Heating indicator

Heating element

Fuse

Water pump

Water temp. sensor

Thermal cut out

Содержание aosbath D25A2

Страница 1: ...User Guide Hot Water Dispenser HWT3...

Страница 2: ...rsonal injury or death The hot water tank should be installed under sink below the faucet Do not place the tank on the countertop or mount it on a wall The recommended height distance between the tank...

Страница 3: ...ented heating system for safe and convenient under sink storage that does not give out steam The hot water inner tank material is a food grade 304 stainless steel tank and comes equipped with a self c...

Страница 4: ...5 Replenish Mode Unlock the system to toggle between two replenishment modes Hot water button Room temp water button 6 Temperature Setting Unlock the system to toggle between four temperature modes Re...

Страница 5: ...plete setup A buzzer will sound to signal an effective reset to factory settings Note If you do not hear the buzzer the system has not been reset Repeat the steps again Press or raise the hot water bu...

Страница 6: ...fter 10 minutes of inactivity the system enters sleep mode and the panel will only display the logo and child lock indicator Touch any key on the panel to exit sleep mode 2 If the heat function of the...

Страница 7: ...ser should be mounted on the countertop and the tank should be below it under the sink 2 Check that you have the necessary tools on hand for the installation An electric drill a pair of needle nosed p...

Страница 8: ...visible Align the faucet with the mounting base and use a wrench to fix the nut firmly on to the mounting base 6 Tighten the nut Nut Wrench 7 Complete installation Place base cap above the nut to com...

Страница 9: ...ocket 2 Before connecting the new water purifier to the hot water tank ensure the water purifier has been flushed correctly Exhaust Water purifier data cable Purified water feed tube Faucet data cable...

Страница 10: ...r Check valve Heater cover steam condenser Right panel Water level sensors Thermal insulation Bottom cover Power supply board LED display Power button Solenoid valve Left panel Heating indicator Heati...

Страница 11: ...nted circuit board Fuse Primary heating element Water Purifier Heating element Thermostat Water level sensors Filter replacement data cable SYSTEM Solenoid valve Purified water direct from filter Room...

Страница 12: ...water leaks Water purifier connection is disconnected Reconnect water purifier and faucet dispenser Faucet dispenser is faulty Replace faucet dispenser Circuit board failure Call AOS Bath service hot...