background image

23

Good venting is essential for a gas fired water heater 

to operate properly as well as to carry away products of 

combustion and water vapor.

 

It is always recommended that a suitable metal drain pan 

be installed under the water heater to protect the area 

from water damage resulting from normal condensation 

production, a leaking tank or piping connections. Refer to 

the “Location Requirements” section. 

Water Heater Sounds

During the normal operation of the water heater, sounds or 

noises may be heard. These noises are common and may 

result from the following:
1.  Normal expansion and contraction of metal parts 

during periods of heat-up and cool-down.

2.  Condensation causes sizzling and popping within the 

burner area and should be considered normal.

3.  Sediment buildup in the tank bottom will create varying 

amounts of noise and may cause premature tank 

failure. Drain and flush the tank as directed under the 

“Draining and Flushing” section.

Smoke/Odor

The water heater may give off a small amount of smoke 

and odor during the initial start-up of the unit. This is due 

to the burning off of oil from metal parts of a new unit and 

will disappear after a brief period of operation. 

Safety Shut-off

This water heater is designed to automatically shut-off in 

the event of the following:
1.  The burner flame is extinguished for any reason.
2.  The water temperature exceeds 195°F (91°C).
3.  Excessive build up of dust on the louvers of the air 

intake chamber. See Maintenance of your Water 

Heater Section.

This unit is also equipped with a flammable vapor sensor 

(FV Sensor), designed to shut off the gas supply in the 

event the water heater has been exposed to flammable 

vapors (e.g., spilled gasoline). 
A high temperature limit switch or ECO (Energy Cut Off) in 
the tank is used to shut off the unit if the water temperature 
exceeds 195°F (91°C). The ECO is a single-use switch, 
which, if activated, requires complete replacement of the 
entire gas control valve/thermostat. If the ECO should 
activate, the water heater cannot be used until the gas 
control valve/thermostat is replaced by a qualified technician. 
Contact your local dealer for service information.

losses and may satisfy your normal hot water needs. If hot 

water use is expected to be more than normal, a higher 

thermostat setting may be required to meet the increased 

demand. When leaving your home for extended periods 

(vacations, etc.) Set the electronic control display tem-

perature “COOLER”     button to its lowest setting. This 

will maintain the water at low temperatures with minimum 

energy losses and prevent the tank from freezing during 

cold weather.

FIGURE 21.

Operational Conditions

Condensation

Whenever the water heater is filled with cold water, some 

condensate will form while the burner is on. A water 

heater may appear to be leaking when in fact the water is 

condensation. This usually happens when:

a.   A new water heater is filled with cold water for the first 

time.

b.   Burning gas produces water vapor in water heaters, par-

ticularly high efficiency models where flue temperatures 

are lower.

c.   Large amounts of hot water are used in a short time and 

the refill water in the tank is very cold.

Moisture from the products of combustion condense on the 

cooler tank surfaces and form drops of water which may fall 

onto the burner or other hot surfaces to produce a “sizzling” 

or “frying” noise. 
Excessive condensation can cause burner flame problems 

due to water running down the flue tube onto the main 

burner. 
Because of the suddenness and amount of water, 

condensation water may be diagnosed as a “tank leak”. 

After the water in the tank warms up (about 1-2 hours), the 

condition should disappear. 
Do not assume the water heater is leaking until there has 

been enough time for the water in the tank to warm up. 
An undersized water heater will cause more condensation. 

The water heater must be sized properly to meet the 

family’s demands for hot water including dishwashers, 

washing machines and shower heads. 
Excessive condensation may be noticed during the 

winter and early spring months when incoming water 

temperatures are at their lowest. 

Gas Control Valve/Thermostat Settings

COOLER

HOTTER

Electronic Control Display

Содержание 315456-004

Страница 1: ...the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fi...

Страница 2: ...lief Valve 16 17 T P Relief Valve and Pipe Installation 17 Combination Space Heating Potable Water System 17 18 Solar Installation 18 Electrical Connections and Wiring Diagram 18 Important Information...

Страница 3: ...ty equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to...

Страница 4: ...s are available Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual Fire or Explosion Hazard Do not store or use gasoline or other flammable vapors...

Страница 5: ...CODES IMPORTANT WHEN BRUSHING ON AN APPROVED NONCORROSIVE LEAK DETECTION SOLUTION DO NOT SPLASH SOLUTION ONTO ELECTRICAL CON NECTIONS SEE PAGE 27 M N A L B P D E Q F G DISCHARGE PIPE DO NOT CAP OR PLU...

Страница 6: ...future users of this water heater will need it for future reference Service to the FVIR System should only be performed by a qualified technician Examples of a qualified technician include licensed pl...

Страница 7: ...ignition sources have been extinguished Fire or Explosion Hazard WARNING Read instruction manual before installing using or servicing water heater Improper use may result in fire or explosion Maintain...

Страница 8: ...ply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the metal drain pan that trigger an alarm or turn off the incoming water to the water heater when water...

Страница 9: ...PPLY WARNING Use a new CSA approved gas supply line Install a shut off valve Do not connect a natural gas water heater to an L P gas supply Do not connect an L P gas water heater to a natural gas supp...

Страница 10: ...these instructions can result in death explosion or carbon monoxide poisoning Explosion Hazard Gas Pipe Capacity Table WARNING Explosion Hazard Gas leaks can not always be detected by smell Gas suppl...

Страница 11: ...y a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do c...

Страница 12: ...for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may requi...

Страница 13: ...ing the manufacturer s instructions and local codes rules or regulations IMPORTANT If you lack the necessary skills required to properly install this venting system you should not proceed but get help...

Страница 14: ...prior to any elbow in the vent system IMPORTANT Existing vent systems must be inspected for obstructions corrosion and proper installation Chimney Connection IMPORTANT Before connecting a vent to a c...

Страница 15: ...he water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperature and pressure relief valve must be installed in the opening marked T...

Страница 16: ...or other chemicals must not be used Chemicals that may contaminate the potable water supply must not be added to the piping system Closed System Thermal Expansion As water is heated it expands thermal...

Страница 17: ...ed into the T P valve discharge opening per the instructions manual 4 Locate the hot water outlet cold water inlet pipes to the water heater 5 Locate the slit running the length of a section of pipe i...

Страница 18: ...tions for leaks Open the nearest hot water faucet and let it run for three 3 minutes to purge the water lines of air and sediment and to ensure complete filling of the tank The Electrical power may th...

Страница 19: ...se review the following checklist and make any required installation upgrades or changes Questions Contact Residential Technical Assistance by referencing the phone number on the front of the Installa...

Страница 20: ...performed 3 Set the ON OFF switch on the gas control to the OFF postition 2 6 This appliance is equipped with a device which automatically lights the burner DO NOT TRY TO LIGHT THE BURNER BY HAND This...

Страница 21: ...code 8 page 31 FIGURE 17 SEQUENCE OF OPERATION System will verify pressure switch operation and start a 5 second pre purge then air intake fan will turn off Ignitor will start a 12 second warm up peri...

Страница 22: ...hermostat see Figures 20 and 21 Using the lowest hot water temperature that meets your needs will also provide the most energy efficient operation of the water heater Never allow small children to use...

Страница 23: ...the water heater cannot be used until the gas control valve thermostat is replaced by a qualified technician Contact your local dealer for service information losses and may satisfy your normal hot wa...

Страница 24: ...s To drain the tank perform the following steps 1 Turn off the gas to the water heater at the manual gas shut off valve and turn off the electrical power to the gas control thermostat valve 2 Open a n...

Страница 25: ...Manifold Burner Assembly 1 Turn off the gas supply to the water heater at the manual gas shut off valve This valve is typically located beside the water heater Note the position of the shut off valve...

Страница 26: ...dirt it may be necessary to check the air intake chamber screen more frequently 2 Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen FIGU...

Страница 27: ...eater Refer to the section of Draining and Flushing section and follow the procedure 5 Disconnect the the flame sense hot surface igniter wire power supply transformer pressure switch fan and display...

Страница 28: ...PERATURE REGULATION section BURNER FLAME YELLOW LAZY 1 Dirt in burner ports 2 Combustion air path restricted 3 Not enough dilution air for proper com bustion 4 Main burner line clogged 5 Obstruction i...

Страница 29: ...MATION SOOTING 1 Insufficient secondary air 2 Low gas pressure 3 Water heater flue or vent system blocked 4 Thermostat not functioning properly 5 Heater installed in a confined area 6 Burner flame yel...

Страница 30: ...ure supply and manifold gas pressures are within requirements in the installation manual Manifold gas pressure is non adjustable if pressure is off by more than 0 3 W C 75 Pa replace the lower control...

Страница 31: ...power for 10 seconds and then back on If this error code will not clear and the ignitor resistance is within specifications replace the lower control 9 FV SENSE Flashing Flammable Vapor Sensor has det...

Страница 32: ...control must be replaced 15 All Segments Flashing The self diagnostic check has detected one or both of the temperature adjustment buttons are stuck 1 Press and release each of the temperature adjustm...

Страница 33: ...DURING TRIAL FOR IGNITION IGNITOR TURNS OFF YES NO IS FLAME SENSE LOST IS REQUEST FOR HEAT SATISFIED GAS VALVE OFF COMBUSTION FAN OFF AFTER POST PURGE DELAY GAS VALVE CLOSES LESS THAN 3 TRIES FOR IGN...

Страница 34: ...w Retainer Clip 16 Manifold Door Gasket 17 Viewport Assembly 18 FV Sensor 19 Outer Door 20 Electrical Transformer 21 Pressure Switch REPAIR PARTS ILLUSTRATION LEGEND Special anode rod see Anode Rod Wa...

Страница 35: ...assembly which contains the manifold tube gasket manifold door manifold component block with retainer clip and flame sense hot surface igniter assembly Natural Gas Item 15 Contains manifold component...

Страница 36: ...36 NOTES...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...niques for residential water heaters bearing a rating plate which has not been altered defaced or removed except as required by the warrantor used in an open system or in a closed system with a proper...

Страница 40: ...M DOES NOT CONSTITUTE PROOF OF PURCHASE OR PROOF OF INSTALLATION DISCLAIMERS NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE ON BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF THE HEATER...

Отзывы: