Error! Use the Start tab to apply “Title 1” to the text need to be displayed here.
22
loading inspection, 2: uploading inspection, 3: loading and uploading inspection)
6.
Note
:
When using the one-key operation function, you need to select the relevant function in the
optional function buttons
, as shown below.
Spindle Function
4.2.
4.2.1.
Spindle speed correlation
1.
The system provides the judgment method of the spindle speed arrival and zero speed arrival. The
parameter setting method can be used to select the method of calculating the number of seconds or the
system spindle speed arrival and zero speed arrival can be notified by using the external signal.
2.
The parameter setting is located in the system value of the user parameters.
Parameter
No.
Parameter Content
8312
Waiting time for arrival of first spindle speed (seconds, -1:
external signal notification)
8313
Waiting time for arrival of second spindle speed (seconds, -1:
external signal notification)
8314
Waiting time for arrival of third spindle speed (seconds, -1:
external signal notification)
8315
Waiting time for arrival of forth spindle speed (seconds, -1:
external signal notification)
8343
[Spindle function] Waiting time for arrival of zero speed of first
spindle (seconds, -1: external signal notification)
8344
[Spindle function] Waiting time for arrival of zero speed of
second spindle (seconds, -1: external signal notification)
8345
[Spindle function] Waiting time for arrival of zero speed of
third spindle (seconds, -1: external signal notification)
8346
[Spindle function] Waiting time for arrival of zero speed of
forth spindle (seconds, -1: external signal notification)